background image

Page 13 of 18

 Operation

Ilumiline SL User Manual Rev. 1

7

Color temperature

000 

 009 No function

010

1800K

011 

 024 1801–2199K

025

2200K

026 

 039 2201–2699K

040

2700K

041 

 054 2701–2999K

055

3000K

056 

 069 3001–3199K

070

3200K

071 

 084 3201–3999K

085

4000K

086 

 099 4001–4499K

100

4500K

101 

 114 4501–4999K

115

5000K

116 

 129 5001–5599K

130

5600K

131 

 144 5601–5999K

145

6000K

146 

 159 6001–6499K

160

6500K

161 

 174 6501–6999K

175

7000K

176 

 189 7001–7999K

190

8000K

191 

 204 8001–9999K

205 

 255 10000K

8

Strobe

000 

 009 No function

010 

 255 Strobe, 1–25 Hz

9

Dimmer speed

000 

 009 No function

010 

 029 Dimmer speed OFF

030 

 069 Dimmer speed 1 (fastest)

070 

 129 Dimmer speed 2

130 

 189 Dimmer speed 3

190 

 255 Dimmer speed 4 (slowest)

Channel Function

Value

Percent/Setting

Содержание Ilumiline SL

Страница 1: ...User Manual Model ID ILUMILINESL...

Страница 2: ...purpose without written consent from Chauvet Document Printing For best results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure the...

Страница 3: ...king 5 DMX Linking 6 Remote Device Management RDM 6 Beam Shaping Filters 6 Mounting 7 Orientation 7 Rigging 7 Procedure 7 4 Operation 8 Ilumicode RDM2go Control 8 Menu Map 8 Configuration DMX 9 Contro...

Страница 4: ...se harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Any changes or modifications not expressly approved by the par...

Страница 5: ...er and Wiring Make sure the power cord is not crimped or damaged Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the p...

Страница 6: ...t for fitting into available space while interchangeable easy to install beam spread filters to help the fixture adapt to various applications and throw distances Additionally the lime emitter allows...

Страница 7: ...Ilumiline SL User Manual Rev 1 Introduction Product Dimensions 0 81 in 20 5 mm 2 59 in 65 9 mm 12 in 305 mm 1 18 in 30 mm 1 91 in 48 6 mm 2 68 in 68 2 mm 3 42 in 87 mm 3 04 in 77 1 mm 0 33 in 8 5 mm 0...

Страница 8: ...ou can power link up to 46 products at 100 V up to 52 products at 120 V up to 75 products at 208 V up to 88 products at 230 V up to 88 products at 240 V or up to 92 products at 277 V Proprietary 2 in...

Страница 9: ...anagement or RDM is a standard for allowing DMX enabled devices to communicate bi directionally along existing DMX cabling Check the DMX controller s User Manual or with the manufacturer as not all DM...

Страница 10: ...oses Make sure that the structure onto which you are mounting the product can support the product s weight See the Technical Specifications for weight information When mounting the product overhead al...

Страница 11: ...ear mode from fastest DIM1 to slowest DIM4 CALIB WHITE 1 11 RED 000 255 Determines the white balance for the color macros GREEN RGBTOW BLUE Determines the white balance when RGBTOW is active COOL PERS...

Страница 12: ...annel Assignments and Values ARC1 3 Channels ARC1 D 4 Channels ARC2 4 Channels See the Starting Address section for the highest starting address you can select for each personality Make sure that the...

Страница 13: ...000 255 0 100 5 Preset color 000 010 No function 011 020 Light Salmon 021 025 Scarlet 026 030 Flame Red 031 045 Dark Salmon 046 050 Sunset Red 051 060 CID To Tungsten 061 065 Soft Golden Amber 066 070...

Страница 14: ...5 5000K 116 129 5001 5599K 130 5600K 131 144 5601 5999K 145 6000K 146 159 6001 6499K 160 6500K 161 174 6501 6999K 175 7000K 176 189 7001 7999K 190 8000K 191 204 8001 9999K 205 255 10000K 7 Strobe 000...

Страница 15: ...21 025 Scarlet 026 030 Flame Red 031 045 Dark Salmon 046 050 Sunset Red 051 060 CID To Tungsten 061 065 Soft Golden Amber 066 070 Urban Sodium 071 080 LEE Yellow 081 085 Ice And A Slice 086 110 Dark Y...

Страница 16: ...4500K 101 114 4501 4999K 115 5000K 116 129 5001 5599K 130 5600K 131 144 5601 5999K 145 6000K 146 159 6001 6499K 160 6500K 161 174 6501 6999K 175 7000K 176 189 7001 7999K 190 8000K 191 204 8001 9999K 2...

Страница 17: ...Select the COLOR option 3 Select the calibration mode from OFF RGBTOW or UC Color Macro White Balance To adjust the color macro white balances 1 Go to the CALIB main level 2 Select the macro to adjus...

Страница 18: ...uency To clean the product follow the instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove...

Страница 19: ...tary 2 in 1 Proprietary 2 in 1 Power Connection Recommended Cable Total Max Cable Length Connector Max Diameter 3 7 ft 1 13 m hardwire to proprietary waterproof cable Power and data interface 14 AWG 2...

Страница 20: ...uest Clearly label the package with an RMA number Iluminarc will refuse any product returned without an RMA number Before sending the product clearly write the following information on a piece of pape...

Страница 21: ...uvetlighting eu Brookhill Road Industrial Estate Pinxton Nottingham UK Website www iluminarc com NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Benelux Address Stokstraat 18 Email BNLtech chauve...

Отзывы: