Ilumen
8
Installation Manual Ilumen PID Box & Ilumen PID Control Box
5.3
M
OUNTING THE
I
LUMEN
PID
S
OLUTION
5.3.1
T
HE
I
LUMEN
PID
C
ONTROL
B
OX
1.
Mark the position of the drill holes
2.
Drill the holes
3.
Insert wall plugs (if necessary)
4.
Screw the Ilumen PID Control Box to the mounting surface
5.
Check if mounted securely
5.3.2
T
HE
I
LUMEN
PID
B
OX
If you choose to mount the Ilumen PID Box you should follow this procedure:
1.
Mark the position of the drill holes
2.
Drill the holes
3.
Insert wall plugs (if necessary)
4.
Screw the Ilumen PID Box to the mounting surface
5.
Check if mounted securely
6
E
LECTRICAL CONNECTION
When installing the Ilumen PID Solution, the AC side of the PV plant must be switched off. Also
the DC switch of the inverter must be switched off. After the installation is done, you can switch
the DC switch back on followed by the AC side of the PV plant.
A standard EU outlet must be available on installation. This outlet should be on at all times. The
ideal solution is to have a single outlet with a single circuit breaker of 16A.
6.1
AC
CONNECTION
To power the Ilumen PID Solution you must connect the Ilumen PID Control Box to the AC grid
with the supplied power cord. Make sure the switch of the Ilumen PID Control Box is off before
connecting both sides of the cord. Don’t switch on the device until commissioning.
6.2
E
ARTH CONNECTION
To receive the best result the frames of the solar modules must be connected to the earth
connector of the Ilumen PID Control Box. For optimal result you must lay a solar cable (6mm2)
to the mounting structure of the solar modules (make sure mounting structures and frames of
the solar modules are electrically conducting). It is important that all frames of all solar modules