SWIFT K11-EN, Rev.A
50
6.4.1 Splice operation
Splice operation consists of4 sub-checkboxesChecka checkbox and each function is activated.
Set value
Description
Auto
Splice automatically starts when closing the windbreak cover.
Pause 1
It temporarily stops after first arrayal completes.
Press
and it goes to the next step.
Pause 2
It temporarily stops after clad arrayal completes.
Press
and it goes to the next step.
Auto heater1
Heater automatically operates after splicing is finished (Wind cover
should be opened)
Auto heater2
Heater operates only when the fiber is located heater inside (left side
heater sensor should be pushed well)
Содержание SWIFT K11
Страница 11: ...SWIFT K11 EN Rev A 11 3 2 Component s name Windbreak cover Battery Monitor Sleeve heater...
Страница 34: ...SWIFT K11 EN Rev A 34 Deleting splice mode i Delete a splice mode by touching ii Select a mode to be deleted...
Страница 36: ...SWIFT K11 EN Rev A 36 Deleting heater mode i Delete a heater mode by touching ii Select a mode to be deleted...