background image

10

TB-6DF1000-P

BATTERY CHARGER 

 

         Charge only MILWAUKEE M18™ Li-Ion batteries in this MILWAUKEE Li-Ion charger. 

Other types of batteries may cause personal injury and damage. 

WHEN TO CHARGE THE BATTERY PACK WITH THIS MILWAUKEE CHARGER

Remove the battery pack from the tool for charging when convenient for you and your job.

MILWAUKEE batteries do not develop a memory when charged after only a partial discharge It is 

not necessary to run down the battery pack before placing it on the charger.

• 

Use the Fuel Gauge to determine when to charge your MILWAUKEE Li-Ion battery pack. 

• 

You can Top-Off your battery pack‘s charge before starting a big job or long day of use.

• 

The only time it is necessary to charge the MILWAUKEE Li-Ion battery pack is when the battery 

pack has reached the end of its charge. To signal the end of charge, power to the tool will drop 

quickly, allowing you just enough power to finish making a crimp. Charge the battery pack as 

needed. 

HOW TO CHARGE THE BATTERY PACK

Align the battery pack with the bay and slide the battery pack into the charger as far as possible. 

The red light will come on, either flashing quickly (battery pack is too hot or cold), flashing slowly 

(battery pack is waiting for another pack to finish charging) or continuous (pack is charging). 

• 

A fully discharged battery pack with an internal temperature in the normal range will charge 

in about 30 to 185 minutes, depending on the battery pack. 

• 

Heavily cycled batteries may take longer to charge completely.

• 

The Fuel Gauge lights on 18V battery packs are displayed as the pack is being charged,  

 

indicating how fully charged the pack is. The fuel gauge will turn off when charging is  

complete. 

• 

After charging is complete, the continuous green light will come on. 

• 

The charger will keep the battery pack fully charged if it is left on the charger. The light  

indicator will flash green during this maintenance charging. 

• 

The second pack inserted in the charger will begin charging when the first pack inserted is 

fully charged.

• 

If the light indicator flashes red and green, check that the battery pack is fully seated into the 

bay. Remove the battery pack and reinsert. If the light continues to flash red and green,  

remove pack(s) and unplug charger for at least 2 minutes. After 2 minutes, plug charger back 

in and insert pack. If the problem persists, contact a MILWAUKEE service facility. 

• 

If the light indicator does not come on, check that the battery pack is fully seated into the bay. 

Remove the battery pack and reinsert. If the light indicator still does not come on, remove 

pack(s) and unplug charger for at least 2 minutes. After 2 minutes, plug charger back in and 

insert pack. If after these attempts the light indicator still does not come on, contact a  

MILWAUKEE service facility. 

Содержание TASKMASTER TB-6DF1000-P

Страница 1: ...F1000 P Read and understand all of the instructions and safety information in this manual before operating or servicing this tool Phone 800 776 9775 513 533 6200 TASKMASTER TOOLS 4730 Madison Road Cin...

Страница 2: ...hank you for buying a TASKMASTER TOOL Our mission is to bring product innovation and exceptional customer service to the marketplace This tool line is reliable dependable and durable for our customer...

Страница 3: ...be offered options to solve any tool replacement parts or repair issues Call 513 533 6200 or 800 776 9775 Monday to Friday 8 00AM to 5 00PM Eastern Time ET MILWAUKEE BATTERIES LIMITED 3 YEAR WARRANTY...

Страница 4: ...ection used for appropriate conditions will reduce personal injuries Do not overreach Keep proper footing and balance at all times This enables better control of the battery operated tool in unexpecte...

Страница 5: ...y be ejected from the battery avoid contact If contact accidentally occurs flush with water If liquid contacts eyes additionally seek medical help Liquid ejected from the battery may cause irritation...

Страница 6: ...6 TB 6DF1000 P Battery release buttons LED worklight Advance trigger Indenter tips Head locking pin Label Release button Carrying loop yBattery pack IDENTIFICATION...

Страница 7: ...7 TB 6DF1000 P KIT INCLUDES 1 Battery Powered Tool 2 Milwaukee Batteries 1 Milwaukee Charger 1 Shoulder Strap 1 Case...

Страница 8: ...time 60 min approx Hydraulic oil Shell Tellus S2 V 15 Operating temperature range 4 to 122 F Dimensions 17 25 in x 12 62 in x 2 5 in L x H x W Weight 14lbs including battery Crimp Capacity Lugs CU co...

Страница 9: ...is complete Fast flashing red Battery is too hot cold Charging will begin when battery reaches correct charging temperature Slow flashing red Battery charge is pending Charging will begin when the fi...

Страница 10: ...fully discharged battery pack with an internal temperature in the normal range will charge in about 30 to 185 minutes depending on the battery pack Heavily cycled batteries may take longer to charge...

Страница 11: ...parts MOUNTING TO THE WALL Use the wall mount guides to mark the hanging points To reduce the risk of injury always unplug the charger and remove the battery from the charger before performing any mai...

Страница 12: ...ckly for 2 3 seconds and the tool will not run Charge the battery pack NOTE Immediately after using the battery pack the Fuel Gauge may display a lower charge than it will if checked a few minutes lat...

Страница 13: ...labeling marking and documentation requirements for shipping Li Ion batteries is dependent upon whether the particular batteries are rated greater than or less than 100 Wh Generally Li Ion batteries...

Страница 14: ...STRAP Be sure to use the wrist strap to keep the tool secure when in use Use shoulder strap as well 2 1 1 1 2 click OPERATING INSTRUCTIONS Be sure to read instructions carefully wear safety goggles a...

Страница 15: ...released 2 To retract the ram push the reverse trigger The ram continues to retract as the release button is held down NOTE Reverse trigger on both sides of tool CRIMPING 1 Retract the ram fully by pr...

Страница 16: ...CAUTION Ensure that the lug is placed securely in the center against the stationary tip on the latch end of the head Before applying full pressure make sure that all 4 indenter tips are contacting th...

Страница 17: ...BODY BUSHING 4 9 HC134 7A HINGE BUSHING 3 10 HC134 7B HINGE BUSHING 1 11 HC134 8 LOCK PIN 1 12 HC134 9 HINGE PIN 1 13 HC134 10 PIN 2 Part Part Description Qty 14 HC134 11 BEARING CASE 2 15 6 1003 DOW...

Страница 18: ...18 TB 6DF1000 P TOOL PARTS BREAKDOWN 1 24 22 23 26 25 20 21 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 33 32 31 30 29 28 27 36 35 34 17 21 20 26...

Страница 19: ...6 HEAD BUSH 1 16 E714313 PUMP BODY MNT 1 17 714315 SLOTTED PAN 2 18 714347 SHELL FRONT 1 Part Number Part Description Qty 19 711867 SUPPORTING LOOP 1 20 710825 COMPRESSION SPRING 2 21 714303 LEVER PD...

Страница 20: ...wipe the indenter tips free of metal shavings Wipe down all steel parts with WD 40 Store the tool in a non humid environment The tool should provide many years of service when given the proper mainte...

Страница 21: ...21 TB 6DF1000 P Notes...

Страница 22: ...22 TB 6DF1000 P Notes...

Страница 23: ...23 TB 6DF1000 P Notes...

Страница 24: ...18 Version 2 TASKMASTER TOOLS 4730 Madison Rd Cincinnati OH 45227 Phone 800 776 9775 513 533 6200 www ilsco com ILSCO CANADA 615 B Orwell St Mississauga ON L5A 2W4 Canada Phone 800 665 2607 905 274 23...

Отзывы: