Air Purging and Oil Filling Procedure
Fill the reservoir with Exxon Univis
®
J26 all temperature
hydraulic oil only.
Do not fill the hydraulic reservoir with any other type
of fluid (such as brake fluid, glycerine, castor oil, etc.).
Filling the reservoir with anything other than hydraulic
fluid will damage the tool and void the warranty.
2. Retract the ram by pulling the release trigger back
while pressing down on the handle.
3. Pump the handle one partial stroke.
4. Peel out the rubber plug (26) and remove the set
screw (27) from the reservoir handle (1).
8. Pump the handle several times to advance the ram.
While holding a
clean
shop cloth over the reservoir,
retract the ram fully. Repeat several times to purge
all of the air from the system.
9. With the pump handle vertical and the ram fully
retracted, fill the reservoir until it overflows.
10. Replace the plug (25) and wipe off excess oil.
11. Pump the handle one stroke and install the reservoir
handle (1). Replace the set screw (27).
12. Cover the set screw with a silicone rubber sealant,
such as Dow Corning
®
RTV Sealant 732™ Multi-
Purpose Sealant.
1. Clamp the tool into a vise with jaw protectors so the
handles are upward, as shown.
5. Unscrew the reservoir handle from the crimping
tool. Remove the plug (25) from the reservoir.
6. Retract the ram fully.
7. Add oil until the reservoir overflows.
Vise with Jaw
Protectors
Rubber
Plug (26)
Remove
set screw (27).
Reservoir
Plug
(25)