Z-Wave Command Class Specific:

COMMAND_CLASS_APPLICATION_STATUS

Device responses Application Rejected Request Command to source node while received
invalid Set command.

COMMAND_CLASS_ASSOCIATION

Device supports two(2) association groups, each group support two(2) nodes maximum.
Group ID one(1) used to send out un-socialite operation and alarm reports. Group ID two(2)
used to send out BASIC SET ON(0xFF) and OFF(0x00) command while vacation mode is enable
and disable.

COMMAND_CLASS_CONFIGURATION

Device reserves 255 bytes memory store space use for upper application. Upper application
could access the memory by configuration command class, default setting always set to zero

Содержание IZ9015ZW-S

Страница 1: ...OLOGY TECHNOLOGY CO LTD CO LTD Add 6F Shuipan building No 3193Binghe Avenue Futian District Shenzhen City China 518033 TEL 86 755 28689800 FAX 86 755 28689801 Email info ilockey com Http www ilockey c...

Страница 2: ...ry Default a Disconnect 1pcs battery b Press and hold the reset button c While holding the reset button reconnect the battery d Until the lock beeps release the reset button e Press digit 1 to retriev...

Страница 3: ...ns Z Wave Every unlocking need be through Z wave Controller Index No 2 digits For each user code It is associate with a unique number we call it index No The Index No is auto generated by lock and sta...

Страница 4: ...e disable vocation mode Function Code 5 programming code 5 enable vocation mode Please be noted that the lock will not accept any user code but programming code only in vocation mode programming code...

Страница 5: ...default the inclusion status of Z Wave is still effective Z wave Generic Information Generic Device Class GENERIC_TYPE_ENTRY_CONTROL Specific Device Class SPECIFIC_TYPE_ADVANCED_DOOR_LOCK FLIRS settin...

Страница 6: ...E_PARAMETERS USER_CODE Z Wave Command Class Specific COMMAND_CLASS_APPLICATION_STATUS Device responses Application Rejected Request Command to source node while received invalid Set command COMMAND_CL...

Страница 7: ...Lock Configuration Command Auto relock timeout fix in eight 8 seconds Device treats constant Unsecure setting of Door Lock Operation as Unsecure with timeout while device auto relock mode is enable C...

Отзывы: