3

Terms:

Programming code: 8 digits. The programming code puts the lock into a programming mode.
If more than 10 seconds pass in between programming entries, the lock will return to normal
operational status. For maximum security it is necessary to change the default Programming
Code.

User code: 6 digits. User code is the normal code for day-to-day operations.

Z-Wave: Every unlocking need be through Z-wave Controller.

Index No.*: 2 digits. For each user code. It is associate with a unique number, we call it index
No. The Index No. is auto generated by lock and starts with 01. The highest Index No. will be
20. Total user index is 20 that can be added to each lock. (* Please log the user code along with
its index No. for deleting reference)

Storehouse mode (Lock-back mode): For each valid entry, lock will automatically relock back in
5 seconds.

Manufacture Default Setting:

Default programming code: 12345678

User code: Up to 20pcs,6 digits

Steps to setup a new lock (please follow the order)

a. Change programming code (For example, change to 23456789)

{12{4}+{23456789 }+{23456789}

b. Add user code (For example, add 123456 to the lock)

{23{1}+{123456 }+{123456}

Functions Detail

Содержание IZ9015ZW-S

Страница 1: ...OLOGY TECHNOLOGY CO LTD CO LTD Add 6F Shuipan building No 3193Binghe Avenue Futian District Shenzhen City China 518033 TEL 86 755 28689800 FAX 86 755 28689801 Email info ilockey com Http www ilockey c...

Страница 2: ...ry Default a Disconnect 1pcs battery b Press and hold the reset button c While holding the reset button reconnect the battery d Until the lock beeps release the reset button e Press digit 1 to retriev...

Страница 3: ...ns Z Wave Every unlocking need be through Z wave Controller Index No 2 digits For each user code It is associate with a unique number we call it index No The Index No is auto generated by lock and sta...

Страница 4: ...e disable vocation mode Function Code 5 programming code 5 enable vocation mode Please be noted that the lock will not accept any user code but programming code only in vocation mode programming code...

Страница 5: ...default the inclusion status of Z Wave is still effective Z wave Generic Information Generic Device Class GENERIC_TYPE_ENTRY_CONTROL Specific Device Class SPECIFIC_TYPE_ADVANCED_DOOR_LOCK FLIRS settin...

Страница 6: ...E_PARAMETERS USER_CODE Z Wave Command Class Specific COMMAND_CLASS_APPLICATION_STATUS Device responses Application Rejected Request Command to source node while received invalid Set command COMMAND_CL...

Страница 7: ...Lock Configuration Command Auto relock timeout fix in eight 8 seconds Device treats constant Unsecure setting of Door Lock Operation as Unsecure with timeout while device auto relock mode is enable C...

Отзывы: