DO NOT PLACE ARTICLES ON OR AGAINST 

THIS APPLIANCE.

DO NOT  USE OR STORE FLAMMABLE 

MATERIALS NEAR THIS APPLIANCE.

DO NOT SPRAY AEROSOLS IN THE VICINITY OF 

THIS APPLIANCE WHILE IT IS IN OPERATION.

DO NOT MODIFY THIS APPLIANCE.

INSTALLATION

I M P O R T A N T

 

The installation of any ILLusion Gas Log Appliance 

must

 be performed only by authorised personnel and in accordance with 

the manufacturer’s installation instructions, local gas fitting regulations, municipal building codes, electrical wiring regulations, 

AS/NZS 5601 Gas Installations and any other statutory regulations.Please read these instructions carefully before proceeding.

PRIOR TO INSTALLATION 

It is highly recommended that the installation of any ILLusion Gas Log appliance is planned on paper before installation begins. 

This will ensure correct performance of the unit and eliminate potential problems.

 

Your ILLusion sales representative can advise on the best position to maximize the performance of the appliance.

In most cases, an 

Authorised ILLusion Installer

 can be arranged to install the unit, however if this is not possible, a 

suitably 

qualified person

 must be used. These appliances are 

not 

designed to be installed by the homeowner.

INSTALLERS CHECKLIST

CHECK CLEARANCES TO COMBUSTIBLES
INSTALL HEATER AND FLUE SYSTEM            
CONNECT GAS   

 

   

    

TEST GAS PRESSURE 

 

 

   

FIT GAS LOG KIT 

 

 

   

FIT OPTIONAL WALL THERMOSTAT   

    

SAFETY  CHECK  

 

CLEARANCE FROM COMBUSTIBLE MATERIALS

:

1. 

These appliances must be installed in accordance with the  regulations, municipal building codes and  

 

 

 

 

AS/NZS 5601 ‘GAS INSTALLATIONS’

2.  

Only an Authorised person should install the appliance.

3.  

This appliance should be inspected prior to installation and the dealer contacted if any problems arise.

4.  

This appliance must be installed with an approved flue system, which terminates outside the building. 

 

A flue system must never terminate within the roof cavity.    

5.  

The unit should be checked periodically for lint.  The fan area especially is prone to lint build up during  

 

 

 

 

normal  operation. Keep the area around the appliance clean and free from lint.

6.  

Only persons familiar with the operation of the unit should use the heater.

7. 

 Do not modify or adjust this appliance. Always contact your ILLusion dealer if any problems arise.

8.  

Annual service by an Authorised service person will ensure trouble free operation for many years.

9.  

This Gas heater is not designed to burn solid fuels. 

NEVER

 use paper, wood or any other fuel in this  

 

 

 

 

appliance.

10.  

Keep the immediate area around the heater free from any combustible materials: i.e.: aerosols, or other   

 

 

 

 

flammables.

11.  

If you smell gas whilst the unit is operating, immediately shut down the unit and turn the gas off at the  

 

 

 

 

supply shut off valve, or the main meter. Contact Illusion or your local gasfitter.

DO NOT ATTEMPT ANY REPAIRS ON THE HEATER YOURSELF. ONLY AN AUTHORISED PERSON MAY REPAIR OR 

ADJUST THE HEATER ACCORDING TO THE MANUFACTURERS INSTRUCTIONS.

PAINT CURING

SOME EXTERIOR SURFACES OF YOUR ILLUSION GAS APPLIANCE HAVE BEEN FINISHED WITH THE 

HIGHEST QUALITY HEAT RESISTANT PAINT. PLEASE NOTE THAT THE INITIAL FIRING OF THE UNIT  MAY 

PRODUCE SOME SMOKE AND ODOUR AS THE PAINT CURES. 

  TO ENABLE CURING, THE UNIT MUST BE 

RUN ON HIGH WITHOUT THE FAN ON FOR APPROX. 3 - 4 HOURS. IT IS ADVISABLE TO KEEP WINDOWS 

AND DOORS OPEN DURING THIS PERIOD IF POSSIBLE.

 

     

SAFETY INFORMATION

 

Содержание MATRIX GFX-L

Страница 1: ...ve been tested and approved in accordance with Australian Standards for installation and operation as described in this manual and have been certified by SAI GLOBAL WARNING DO NOT MODIFY THIS APPLIANC...

Страница 2: ...ce has been fully tested and approved to Australian Standards NOTE MATRIX GAS LOG FIRES MODELS GFX L GFX M AND GFX S ARE DESIGNED TO BE INSTALLED IN A SUITABLY CONSTRUCTED WALL OR FIREPLACE FACADE THE...

Страница 3: ...ion Matrix series of Gas Log Fires are correct at the time of printing It is always advisable to check dimensions and clearances with your Illusion dealer before commencing installation thus avoiding...

Страница 4: ...gas valve THE FOLLOWING INDICATES SITUATIONS OF ABNORMAL OPERATION OF THE APPLIANCE WHEN THE APPLIANCE IS OPERATING 1 The flames appear excessively large and or sooting occurs on the logs 2 You can sm...

Страница 5: ...fuel effect which is designed to operate with luminous flames and may exhibit slight carbon deposition PILOT FLAME IGNITION Depress and turn the control knob to the PILOT position Depress the button a...

Страница 6: ...CONTACT WITH THE GLASS IF THE PRIMARY GUARD IS NOT FITTED ADDITIONALLY A SECONDARY FIRE SCREEN MAY BE APPROPRIATE WHEN SMALL CHILDREN OR THE INFIRM ARE IN THE VICINITY OF THE APPLIANCE WARNING DO NOT...

Страница 7: ...AS NZS 5601 GAS INSTALLATIONS 2 Only an Authorised person should install the appliance 3 This appliance should be inspected prior to installation and the dealer contacted if any problems arise 4 This...

Страница 8: ...127MM STAINLESS STEEL ACTIVE FLUE MUST BE USED FOR THE REAR FLUE MODEL GALVANISED STEEL MAY BE USED FOR ACTIVE FLUE ON THE VERTICAL FLUE MODEL MINIMUM OVERALL HEIGHT OF FLUE SYSTEM WHEN INSTALLED IS...

Страница 9: ...M a d e G a s L o g F i r e s INSTALLATION OPTIONS 1 2 INTO FABRICATED ENCLOSURE VERTICALLY OR THROUGH REAR WALL AS 5601 AG 601 PLEASE NOTE ALL ILLusion GAS LOG FIRES MUST BE INSTALLED BY AN AUTHORIS...

Страница 10: ...s L o g F i r e s INSTALLATION OPTION 3 AND 4 INTO EXISTING CHIMNEY VERTICALLY OR THROUGH REAR WALL OF CHIMNEY PLEASE NOTE ALL ILLusion GAS LOG FIRES MUST BE INSTALLED BY AN AUTHORISED PERSON IN ACCOR...

Страница 11: ...og B GFX S onto the pins in the rear log and middle log as shown 7 Fit the left hand side top log onto the pins in the rear log and front lhs log as shown CHECK THE LOCATION OF ALL THE LOGS TO ENURE T...

Страница 12: ...HE PRESSURE TEST POINT SEE BELOW NOTE BOTH INLET AND MANIFOLD PRESSURES SHOULD BE CHECKED USING THE VALVE PRESSURE PORTS ON THE GAS VALVE PROCEDURE TURN VALVE TO OFF POSITION LOOSEN INLET PRESSURE POI...

Страница 13: ...ff the burner holes The logs should not have any sooting black areas If there is a problem call an authorised gas fitter or your local dealer 4 The appliance and flue system must be inspected by an au...

Страница 14: ...RIX GFX L M S Spare Parts Spare parts are available from your supplier Refer to rear of this manual for contact details 1 2 3 4 5 6 1 Firebox body main 2 Fascia 3 Top grill assembly 4 Burner assembly...

Страница 15: ...g F i r e s INSTALLATION OF FASCIAS TRIMS FLOOR MOUNT FASCIA The Wall mounted fascia is attached to the outer case assembly by locating the fascia bottom tabs A over the outer case assembly attaching...

Страница 16: ...L o g F i r e s INSTALLATION OF FASCIAS WALL MOUNT FASCIA The Floor mount fascia is attached to the outer case assembly by locating the fascia bottom tabs A over the outer case assembly attaching 2 s...

Страница 17: ...ergy saving method of operating the fan SHUT DOWN It will also shut down the fan 10 to 15 minutes after the heater is turned off once the firebox has cooled sufficiently REMOTE CONTROLLER OPTION The a...

Страница 18: ...E CHANGED BY REMOVING THE REAR ACCESS COVER THE RECEIVER USES 4 AA BATTERIES WHICH CAN BE ACCESSED BY REMOVING THE SLIDING COVER ON THE REAR OF THE RECEIVER UNIT THE RECEIVER IS LOCATED ON THE RHS OF...

Страница 19: ...ler SYMPTOM The logs have a build up of black soot in some areas POSSIBLE CAUSE Usually indicates incorrect positioning of logs if the unit has just been installed If the unit has been installed for s...

Страница 20: ...Gippsland Hwy Dandenong Sth Victoria 3175 Australia Telephone 61 3 9793 7520 email service Illusionfires com au www Illusionfires com au Illusion Australia Pty Ltd reserves the right to alter specifi...

Отзывы: