RMV-71 Operations
Copyright illunis LLC, 5/19/2014
Page 48
4.5: Exposure:
Software Controlled Trigger
This command forces an internal trigger from a
software command. The soft trigger pulse has a
width in us as specified in the data field. The range
is 1 to 65535 ms (65sec). 10ms is typical usage.
Serial Commands
Target
Index
Command
R/W
Description
0x02
0x05
Soft Trigger
W
Issue a soft trigger with width in ms
0x02
0x06
Soft Trigger high
W
Sets trigger high
0x02
0x07
Soft Trigger low
W
Sets trigger low
Quick FAQ’s:
►
Exposure must be programmed before issuing any
trigger !
►
Hardware triggers must be inactive when using
software trigger !
4.4: Exposure:
Strobe Signal
The RMV Strobe
signal is a 3.3V LVTTL signal
that is active whenever the sensor is triggered and ex-
posing and image. The strobe signal is very useful for
analyzing and optimizing imaging applications.
The
strobe can be used to activate an illumination source.
The strobe signal should cannot drive significant current
and should be buffered if used in this fashion.
Quick FAQ’s:
►The strobe signal can be used to determine
triggerd frame timing.
►
The strobe signal can be found on the RMV power
connector and is a 3.3V LVTTL signal.
Serial Commands
Target
Index
Command
R/W
Description
0x04
0x0e
Strobe Control
Write
0x0000 = negative strobe polarity
0x0001 = positive strobe polarity
All manuals and user guides at all-guides.com