10 Installation
(for qualified installers only)
Travis Industries
4100310
100-01207_002
Electrical Connection
•
The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified
installer and must meet all local codes.
•
Make sure the circuit breaker is shut off prior to working on any electrical lines.
•
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
•
You may wish to install a wall switch to interrupt the circuit leading to the fireplace. A switch and wall
plate are included with the fireplace.
Do not install a dimmer
(rheostat) on this fireplace, this will
damage the bulbs.
Wiring the Junction Box
Remove and discard the two shipping screws on the candle tray (see Figure 5 item “a”). Lift the tray from
the fireplace, making sure to un-plug the socket from the junction box inside the fireplace (Figure 5 item
“b”). The power supply is routed into the fireplace from below. You may wish to use the included wall
switch (Figure 5 item “c”) to control the fireplace. The junction box is shipped below the candle tray.
Remove the cover plate, receptacle, and romex connector from the junction box (Figure 5 item “d”).
Route the power supply through the romex connector and connect to the receptacle. The romex
connector secures the junction box to the base of the fireplace and prevents the wire from dislodging
(Figure 5 item “e”). An optional remote control is included (Figure 5 item “f”). If you wish to use the
remote, plug the remote into the receptacle and the candle tray into the remote.
a
b
c
d
e
f
Figure 5