8.6
8.7
8.7a
1
2
3
4
28
RESETTING THE THERMAL CUT-OUTS
It is not necessary to switch the system off, but before resetting
the cut-outs, ensure there is solution in both the processing tanks.
To reset, push the thermal cut-out reset into the processor until it
clicks, and the thermal cut-out light is switched off.
REPLACING A ROLLER TENSION SPRING
Processor
See figure 8.4.
All roller pairs are secured in the rack assembly by two springs,
one at each end. The normal spring tension retains the rollers in
position. If the springs become distorted or weak, the springs
should be replaced.
Note
Left and right hand springs are not interchangeable.
Remove the spring as follows:
Switch the system off (see section 6).
Lift out the appropriate roller rack (see section 8.4, operation 4).
Lift the roller, complete with bearings, out of the slot in the rack
end plates and disengage the roller from the springs.
Unhook the spring from the retaining hole in each end plate.
IL194
Figure 8.4
Replacing a roller tension spring - processor
Содержание ILFOLAB 2150RC
Страница 6: ...Figure 1 1 ILFOLAB 2150RC processing system typical installation ILFORD O I ILFOLAB 2 1 50RC IL167A 3...
Страница 8: ...Figure 2 1 Controls and indicators IL168A O I 1 5...
Страница 12: ...Figure 3 1 Installation general 150mm 6in 150mm 6in 150mm 6in IL169A 4 3 5 6 7 8 10 11 2 1 9 9...
Страница 16: ...Figure 3 2 Installation dryer IL170A 1 O I 2 60 Hz 50 Hz B A 4 3 3 6 5 6 5 13...
Страница 26: ...Figure 8 1 Internal view of processor O I ILFORD ILFOLAB 2 1 50RC IL172 7 8 9 6 3 5 5 3 6 3 9 4 2 3 3 8 1 23...
Страница 28: ...Figure 8 2 Internal view of dryer IL173A 1 2 6 5 4 3 25...