OP-131Tx_V2 User Manual.docx
Page
18
of
19
30-Aug-2018
© 2018 IKUSI ANZ Pty Ltd - All rights reserved - Reproduction without consent is prohibited
6.2 Troubleshooting
Should a problem occur, see if the symptoms are listed in Table 6-1.
Table
6-1: Troubleshooting Solutions
Indicator
status
Alarm menu
content
Fault phenomenon
Solution
Run
indicator
green flash
Contact Customer Service.
RF indicator
red flash
RF IN Status
LOW (HIGH)
RF input is low
(high)
Verify the optical
transmitter is operating
within the proper input level
threshold range (-25~-
5dBm).
If that does not correct the
problem, contact Customer
Service.
Laser
indicator
red flash
Laser Bais
HIGH
The laser is off
Contact Customer Service.
Laser TEC
HIGH
The laser is off
Verify that the unit is
operating within the proper
temperature range
(0~+50°C).
Verify that nothing is
obstructing airflow through
the openings in the front
and back of the unit.
Recall factory settings by
pressing the key on the front
panel (see Section 3).
If that does not correct the
problem, contact Customer
Service.
OutPutPower
Status HIGH
(LOW)
The laser is off
Reboot the equipment. If
that does not correct the
problem, contact Customer
Service.