Take a lot of time to measure when fixing the first MuteClip LP’s and MuteClip Channel, as you only want a few mm 

of the MuteClip Channel sitting proud of the bottom of the joists.

•  Attach MuteClip Channels into MuteClip LP’s, channels must run parallel to the joists.

 

+

MuteClip Channels must overlap by 200mm, fix 4 self-tapping screws into the shoulders of the MuteClip 

Channels to give a secure join.

 

+

MuteClip Channels must not overlap on a MuteClip LP.

•  You may wish you install one MuteClip Channel with a couple of MuteClip LP’s, then use a laser level to mark along 

the joist for the rest of the MuteClip LP’s

• 

Fix your first layer of Acoustic Plasterboard to the MuteClip Channels.

 

+

Acoustic Plasterboard must not be in direct contact with any adjacent surfaces. There must be a 2-5mm gap 
around the perimeter of the room.

•  Seal the perimeter and any other gaps with Acoustic Sealant.
•  Adhere Tecsound to the Acoustic Plasterboard using Tecsound’s self-adhesive backing.

 

+

It may be easier to cut Tecsound into manageable sized pieces for ease of installation.

• 

Fix your second layer of Acoustic Plasterboard and stagger the joins from the first layer, making sure that the 

screws go into the MuteClip Channels.

 

+

Again, leave a 2-5mm gap around the perimeter of the room.

•  Seal the perimeter and any other gaps with Acoustic Sealant.
• 

Scrim tape all joins and finish with a skim plaster.  

Configurations

 

Standard Diamond LP

Please contact iKoustic to confirm correct configurations appropriate for your system.

If you need any assistance, please call us on 01937 588 226.

Содержание MuteClip

Страница 1: ... ikoustic com Creating Quieter Spaces Together Creating Quieter Spaces Together MuteClip Installation Guides Wall 02 To Stud Wall 04 Direct to Wall 06 Windows Doors Openings and Pitched Ceilings Ceiling 08 Direct to Concrete Ceiling 10 To Battened Concrete Ceiling 12 To Wooden Joist Ceiling 15 MuteClip XP 17 MuteClip LP ...

Страница 2: ...n be friction held between the joists battens if required use thin wiring to keep it suspended Measure up and mark out the appropriate locations for the MuteClips See configurations or contact iKoustic for appropriate dimensions The perimeter MuteClips must be no further than 100mm from the adjacent surfaces MuteClips to be spaced a maximum of 600mm apart vertically MuteClip to Stud Frame 1st Plas...

Страница 3: ...rect contact with any adjacent surfaces There should be a 2 5mm gap around the perimeter of the surface Seal the perimeter and any other gaps with Acoustic Sealant Adhere Tecsound to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Tecsound into manageable sized pieces for ease of installation Fix your second layer of Acoustic Plasterboard stagger the joist ...

Страница 4: ...nto brickwork to secure the MuteClip Drill hole in the wall plug this hole and fix the screw through the Clip into the hole MuteClips to be spaced a maximum of 600mm apart vertically MuteClip centres to vary betwen 600 and 1200m centres creating a Diamond configuration See configurations or contact iKoustic for appropriate dimensions Attach MuteClip Channels into MuteClips channels must run horizo...

Страница 5: ...ust be a 2 5mm gap around the perimeter of the room Seal the perimeter and any other gaps with Acoustic Sealant Adhere Tecsound to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Tecsound into manageable sized pieces for ease of installation Fix your second layer of Acoustic Plasterboard and stagger the joins from the first layer making sure that the screws...

Страница 6: ... window to ensure the plasterboard is supported along the edge Perimeter Details MuteClip Installation Guide Wall Windows Doors Openings and Pitched Ceilings Windows and Doors Please contact iKoustic to confirm correct configurations appropriate for your system If you need any assistance please call us on 01937 588 226 MuteClip Stud System Window Side View MuteClip Stud System Door Top View MuteCl...

Страница 7: ...is supported along the edge MuteClip Installation Guide Wall Windows Doors Openings and Pitched Ceilings Pitched Ceilings Please contact iKoustic to confirm correct configurations appropriate for your system If you need any assistance please call us on 01937 588 226 MuteClip Channel must not be installed over any opening or vent in your wall or ceiling system To overcome this install a MuteClip an...

Страница 8: ...lt the MuteClips directly into the concrete ceiling at the appropriate centres See configurations or contact iKoustic for appropriate dimensions Attach MuteClip Channels into MuteClips MuteClip Channels should overlap by 200mm fix 4 self tapping screws into the shoulders of the channels to give a secure join MuteClip Channels should not overlap on a MuteClip Insert Acoustic Mineral Wool behind the...

Страница 9: ...und to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Tecsound into manageable sized pieces for ease of installation Fix your second layer of Acoustic Plasterboard and stagger the joins from the first layer making sure that the screws go into the MuteClip Channels Again leave a 2 5mm gap around the perimeter of the room Seal the perimeter and any other gap...

Страница 10: ...igurations or contact iKoustic for appropriate dimensions The perimeter MuteClips must be no further than 100mm from the adjacent walls Screw MuteClips into the appropriate joists Attach MuteClip Channels into MuteClips channels must run perpendicular to the joists battens MuteClip Channels must overlap by 200mm fix 4 self tapping screws into the shoulders of the MuteClip Channels to give a secure...

Страница 11: ...mm gap around the perimeter of the room Seal the perimeter and any other gaps with Acoustic Sealant Adhere Tecsound to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Tecsound into manageable sized pieces for ease of installation Fix your second layer of Acoustic Plasterboard and stagger the joins from the first layer making sure that the screws go into the...

Страница 12: ...er MuteClips must be no further than 100mm from the adjacent walls Screw Clips into all the appropriate joists Attach MuteClip Channels into MuteClips channels must run perpendicular to the joists MuteClip Channels must overlap by 200mm fix 4 self tapping screws into the shoulders of the MuteClip Channels to give a secure join MuteClip Installation Guide Ceiling To Wooden Joist Ceiling MuteClip to...

Страница 13: ...he perimeter of the room Seal the perimeter and any other gaps with Acoustic Sealant Adhere Tecsound to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Tecsound into manageable sized pieces for ease of installation Fix your second layer of Acoustic Plasterboard and stagger the joins from the first layer making sure that the screws go into the MuteClip Chann...

Страница 14: ...est Yorkshire LS22 7DN Creating Quieter Spaces Together www iKoustic com 01937 588226 Sales ikoustic com 14 4 6 Square Please contact iKoustic to confirm correct configurations appropriate for your system If you need any assistance please call us on 01937 588 226 ...

Страница 15: ...ct iKoustic for appropriate dimensions The perimeter MuteClip XP s must be no further than 100mm from the adjacent walls Screw MuteClip XP s into all the appropriate joists MuteClip XP s central track fixing should be no closer than 25mm from the bottom of the joist MuteClip XP Installation Guide Ceiling To Wooden Joist Ceiling MuteClip XP to Wooden Joist 1st Plasterboard to Channel 2nd Plasterboa...

Страница 16: ...the MuteClip Channels Acoustic Plasterboard must not be in direct contact with any adjacent surfaces There must be a 2 5mm gap around the perimeter of the room Seal the perimeter and any other gaps with Acoustic Sealant Adhere Tecsound to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Tecsound into manageable sized pieces for ease of installation Fix your ...

Страница 17: ...t iKoustic for appropriate dimensions MuteClip LP s attach to the side of the joists The perimeter MuteClip LP s must be no further than 100mm from the adjacent walls Screw MuteClip LP s into the side of all the appropriate joists MuteClip LP s should be no closer than 25mm from the bottom of the joist MuteClip LP Installation Guide Ceiling To Wooden Joist Ceiling MuteClip LP to Wooden Joist 1st P...

Страница 18: ...of the MuteClip LP s Fix your first layer of Acoustic Plasterboard to the MuteClip Channels Acoustic Plasterboard must not be in direct contact with any adjacent surfaces There must be a 2 5mm gap around the perimeter of the room Seal the perimeter and any other gaps with Acoustic Sealant Adhere Tecsound to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Te...

Отзывы: