Ikelite 9306.35 Скачать руководство пользователя страница 5

5

Maintenance and Storage

After using the Wide Angle Port in water (especially saltwater), rinse with
fresh tap water and dry with a soft non-abrasive cloth. Wipe the surface
of the port lens gently with the soft non-abrasive cloth to prevent debris
buildup that can cause spotting. Use only water and a non-abrasive mild
soap solution to clean the port lens.

Caution: 

Do not attempt to dry the housing or port by exposing it to heat

from a hair dryer, radiator, etc. This could damage either.

Store the port in a cool, dry place with the port cover attached. Place in a
resealable plastic bag for short and long term storage.

DO NOT store any accessory lens attached to a housing port.
Temperature changes can make the lens hard to remove from the port
and cause accidental removal of the port.

Checking the O-ring Seal

1. After you have properly attached the Wide Angle Port and checked the o-ring

seal, replace the housing back WITHOUT a camera attached.

2. Place the housing in shallow water such as a bathtub or swimming pool.
3. After a couple minutes, remove and dry the housing completely.
4. Before opening the housing, look to see if any water droplets are inside.
5. If no droplets are present, remove the housing back and check again for 

droplets. If none are present, then the housing is watertight and safe for 
diving. If ANY water is present inside the housing DO NOT dive. Repeat the 
Port Removal and Installation process until no water is present. 

-

Before attaching a housing port, always double-check the o-ring and sealing 
surfaces to make sure there is no debris present which could cause a leak.

Содержание 9306.35

Страница 1: ...for your purchase of Ikelite equipment Please read this instruction manual completely before attempting to operate or dive with this product Wide Angle Port I n s t r u c t i o n M a n u a l 9306 35 for Canon G15 ...

Страница 2: ...age Contents P 3 General Information P 3 Port Removal and Attachment P 3 Checking the O ring Seal P 5 Maintenance and Storage P 5 Limited Warranty P 6 Returning Products for Service P 7 Technical Support P 7 Ikelite Address and Website Back Page ...

Страница 3: ...alled 67mm threaded external accessory lenses may be removed and replaced underwater Package Contents 9306 35 Wide Angle Port 0200 Port Cover Ikelite Silicone Lubricant Port Removal and Installation A strap wrench will be needed to remove and install ports on your Ikelite housing Ikelite offers strap wrench 0945 01 through any Ikelite authorized dealer Lightly lubricate the port o ring with the su...

Страница 4: ...Facing the front of the housing attach the Wide Angle Port to the housing by rotating port clockwise into the port hole opening until snug 2 Place a Strap Wrench over the housing port 3 Tighten Strap so the Handle is as close to the port as possible 4 Rotate the Handle clockwise to tighten port Diagram B Tighten until a good o ring seal dark circular line can be seen from inside the housing Diagra...

Страница 5: ...es can make the lens hard to remove from the port and cause accidental removal of the port Checking the O ring Seal 1 After you have properly attached the Wide Angle Port and checked the o ring seal replace the housing back WITHOUT a camera attached 2 Place the housing in shallow water such as a bathtub or swimming pool 3 After a couple minutes remove and dry the housing completely 4 Before openin...

Страница 6: ... Defective products should be returned to Ikelite postage paid Ikelite will at its sole discretion repair or replace such products and will return to customer postage paid All other claims of any nature are not covered Except as mentioned above no other warranty expressed or implied applies to this Ikelite product Limited Warranty ...

Страница 7: ... interested in performing any service to ensure that all products perform as intended Evidence of purchase date must be provided to obtain warranty service No prior authorization is required You may return directly to us or through your dealer Please include a brief description of the problem any relevant email correspondence and or instructions on what you want us to do Always include name shippi...

Страница 8: ...Ikelite Underwater Systems 50 West 33rd Street Indianapolis IN 46208 USA 9306 35_G15_Wide_Angle_Port_1 1112 www ikelite com ...

Отзывы: