This product has been water pressure tested at the factory and is depth

rated to 200 ft. (60m). Thoroughly inspect and immerse the empty

housing completely in water before installing a camera. If any fogging

occurs or droplets of water enter the housing, do not install a camera.

Clean the housing main o-ring and retest to make sure that it is

watertight. Refer to the Troubleshooting section, page 17.

Please read your camera manual thoroughly to have a full

understanding of each camera function.

If you are new to underwater photography, be sure to read the Photo

Tips section, page 16. 

Preparation

  Initial Camera Setup 

(before placing camera in housing)

- Set Mode Dial to “A” Aperture Priority. Manually adjust aperture setting to

achieve the best exposure for your shooting conditions. The shutter 

speed will be locked at 1/30th second. If a faster shutter speed is          

desired, set Mode Dial to “M” Manual mode to manually adjust both       

aperture and shutter speed settings.

- Set Image Size to “L: 17M” and Aspect Ratio to “16:9” widescreen view.

- Set Quality to “Fine.”

- Set Drive Mode to “Single Shooting.” 

- Set Flash Mode to     “Fill-flash” and Focus Mode to “Single-shot AF.”

- Set Autofocus Area to “Center” and ISO to “200.”

-  Set Metering Mode to “Center” and White Balance to “Auto WB.” For

best results, manually set white balance for each working depth.

- Set DRO/Auto HDR, Digital Zoom, and AF Illuminator to “OFF.”

- Set SteadyShot to “On” and Auto Review to “10 Sec.”

- Set Red Eye Reduction to “Off” and Auto Review to “5 Sec.”

- Insert and Format an SDHC memory card.

- Set Date and Time.

* All menu functions not mentioned should be set to user preference.

Содержание 6116.11

Страница 1: ...Sony RX100 II DSC RX100M2 B Thank you for your purchase of Ikelite equipment Please read this instruction manual completely before attempting to operate or dive with this product Please refer to the...

Страница 2: ...amera P 7 Using the Built in Camera Flash P 8 Closing the Housing P 8 Usage P 9 Final Check P 9 Zoom Control P 9 Deflector Purpose P 9 Deflector Removal Installation P 10 Diffuser Purpose P 10 Diffuse...

Страница 3: ...roducts for Service P 23 Product Registration P 24 Ikelite Digital Housing Silicone Lubricant Vinyl Port Cover Package Contents Diffuser and Deflector Lanyard attached to housing Extra Control Tips Wi...

Страница 4: ...y adjust aperture setting to achieve the best exposure for your shooting conditions The shutter speed will be locked at 1 30th second If a faster shutter speed is desired set Mode Dial to M Manual mod...

Страница 5: ...er Release Zoom Lever External Tray Mount Control Ring Lid Snap Lens Port ON OFF Power Button Control Ring To properly engage the Control Ring on the surface or in shallow water apply slight downward...

Страница 6: ...on Parts of the Housing Back View 7 Set Tracking Focus 8 Flash Mode Right Button 9 Exp Comp Down Button 10 Playback Button 11 Guide Delete Button Control Wheel Note A small section is cut away from th...

Страница 7: ...the camera on the tray DO NOT extend the camera flash 5 Using a coin or screwdriver preferred secure the camera with the tray mounting bolt which threads into the camera s tripod socket diagram A Open...

Страница 8: ...h down on the lid snaps until they snap into place Lid snaps on opposite sides of the housing should be closed at the same time Be sure they are down far enough to engage the lid snap lock Using the B...

Страница 9: ...sing back and close the lid snaps Visually check the seal again Zoom Control lever type only After you have used the housing s zoom control it must be returned to the center position to disengage If t...

Страница 10: ...port on the housing can block a portion of the light from the built in camera flash This can result in a shadow in a lower corner of the picture frame The Diffuser will help eliminate the shadow In a...

Страница 11: ...to the housing mounts Finish tightening the tray to the housing using a flathead screwdriver Do not overtighten Attach Ikelite Strobe Arm to Housing Handle If you have purchased an optional Ikelite Tr...

Страница 12: ...c in the lens port as a camera lens After use rinse and gently dry the outside lens port to avoid water spotting To clean use a mild soap solution or lens cleaner Do not rinse the inside port glass Do...

Страница 13: ...y a thin coating of lubricant Only apply enough lubricant to make the o ring feel slick Do Not stretch the o ring This light coating of lubricant will help to keep the o ring from drying out and will...

Страница 14: ...ring Some of the controls have long shafts These controls can be pulled out exposing the shaft see diagrams B and C page 15 To lubricate the control gently pull on the knob until the stainless steel...

Страница 15: ...Lubricate end of shaft before reinserting into gland Diagram B Control Maintenance continued Slide the shaft back into the control gland and gently slide it back and forth a few times without fully re...

Страница 16: ...t down on subjects as they will quite often blend into the background and be difficult to see in the photograph Shoot subjects straight on or shoot up at a slight angle using the blue water as a contr...

Страница 17: ...ticky see the Control Maintenance section pages 14 15 Return housing to Ikelite for routine maintenance Problem Solution Image is over underexposed or a corner of the image is dark Check that the came...

Страница 18: ...ndense any trapped moisture forming fog on the lens port Close the housing in an air conditioned room or vehicle or in front of an air conditioner The housing should not be direct in sunlight for an e...

Страница 19: ...a installed and pressure test or take diving Return housing to Ikelite for evaluation Problem Solution Pictures are too blue or too green Use custom manual white balance if available Reset for each wo...

Страница 20: ...dle combinations offset the slightly positive buoyancy of the housings Handles offer attachment points for external lighting systems External Strobes A separate external strobe adds color to restore t...

Страница 21: ...ernal Accessory Lenses An external wide angle conversion lens increases angle of coverage so you can get much closer to your subject while still fitting everything in the frame By reducing the amount...

Страница 22: ...ecommended accessories for your housing Recommended Accessories continued 22 Customer Support Please read the troubleshooting section of this instruction manual before contacting Ikelite Customer Supp...

Страница 23: ...oblem any relevant email correspondence and or instructions on what you want us to do Always include name shipping address email address and phone number inside of the package Send postage paid to Ike...

Страница 24: ...0 West 33rd Street Indianapolis IN 46208 USA www ikelite com Product Registration Please go to www ikelite com to register your Ikelite housing within 15 days of purchase 6116 11_Sony_RX100II_02 0214...

Отзывы: