Safety Precautions 

Please follow the safety instructions below: 

Before  you  use  this  unit,  be  sure  to  familiarize  yourself 
with this “Safety Precautions” and the “Operation Manual” 
to use the unit in the proper manner. 

After  reading  these  documents,  be  sure  to  keep  them  in  a 
safe  place  for  your  reference  whenever  the  information  is 
required. 

 

 

Concerning Pictographic Symbols 

The  pictographic  symbols  contained  in  this  “Safety 
Precautions” and placed on the units are provided by using 
various  pictographs  to  ensure  that  you  use  this  unit  in  the 
safe  manner  and  to  protect  yourself  or  other  persons  from 
any  hazards  and  to  prevent  any  damages  occurring  from 
this unit. 

The  pictographic  indications  and  their  meanings  are  given 
below.  Please  thoroughly  understand  these  indications  and 
their meanings before using this unit. 

Please  understand  that  there  may  be  some  pictographic 
symbols that may not apply to the unit you purchased. 

 

 

 

Warning 

This symbol indicates a content that any erroneous 
handling of this unit committed by ignoring this 
symbol may cause an accident resulting in death or 
serious injury.   

 

Caution 

This symbol indicates a content that any erroneous 
handling of this unit committed by ignoring this 
symbol may cause an accident resulting in serious 
injury or in property loss or damage. 

  (Note)    The 

 symbol indicates a content to call for the user’s attention. 

 

Example of Symbols 

 

The 

  symbol indicates that the action is prohibited.    In the 

diagram or in its vicinity, the concrete contents of prohibition 
is illustrated.    (In the diagrams at left, it is a caution against 
disassembly of the unit.)

 

 

The 

  symbol indicated that the action must be carried out in 

a coercive manner.    In the diagram, the concrete content of 
caution is illustrated (In the diagrams at left, the power plug 
must be pulled out.)

 

 

Warning 

When you use the product:

 

 

Do not place any container containing water or any liquid or 
small metallic pieces on the unit! 

Spilt liquid entering inside the unit may cause a fire or an 
electric shock accident.

 

 

Do not use the unit by applying any voltage other than the 
specified voltage! 

Application of an unspecified voltage to the unit may cause 
a fire or an electric shock accid1ent.

 

 

Do not allow any metallic or combustible material to enter or 
be dropped into the unit from an opening! 

This may cause a fire or an electric shock accident. 

 

Do not make any alterations to this unit! 

This may cause a fire or an electric shock accident. 

 

When you install the product:

 

 

Do not install this unit on an unstable position! 

By doing so, the unit may be dropped or fall down, causing 
a personal injury.

 

 

Do not use the unit by applying any voltage other than the 
specified voltage! 

Application of an unspecified voltage to the unit may cause 
a fire or an electric shock accident.

 

 

Be  sure  to  employ  a  specialized  engineering  constructor  to 
install the unit in place! 

This unit must be securely installed in place by using the 
specified method.    Otherwise, it may be dropped or fall 
down, causing a fire, an electric shock, or a personal injury. 
If the unit is to be installed on the wall or on the ceiling, be 
sure to employ a specialized engineering constructor for the 
work.

 

 

Do not make any alterations to this unit!

 

This may cause a fire or an electric shock accident.

 

 

When a trouble has occurred: 

 

If  an  abnormal  condition  should  occur,  indicated  by  smoke, 
strange odor, or noise, be sure to turn off the power switch and 
unplug the power plug from the outlet! 

If you keep using the unit as is, a fire or an electric shock 
accident may occur.    Make sure that the smoke has gone 
out and contact our sales agent or the sales person in charge.

 

 

If  water  or  any  foreign  object  has  entered  inside  the  unit,  turn 
off  the  power  switch  and  unplug  the  power  plug  from  the 
outlet! 

If you keep using the unit as is, a fire or an electric shock 
accident may occur.    Contact our sales agent or the sales 
person in charge.

   

 

If  the  unit  is  dropped  down  or  its  case  is  broken,  turn  off  the 
power switch and unplug the power plug from the outlet!   

If you keep using the unit as is, a fire or an electric shock 
accident may occur.    Contact our sales agent or the sales 
person in charge.

 

 

If  this  unit  should  go  out  of  order,  turn  off  the  power  switch 
and unplug the power plug from the outlet! 

If you keep using the unit as is, a fire or an electric shock 
accident may occur.    Contact our sales agent or the sales 
person in charge.

 

 

Do  not  use  any  damaged  (with  the  core  wire  exposed  or 
broken) power cord!   

If  you  keep  using  the  unit  as  is,  a  fire  or  an  electric  shock 
accident  may  occur.    Contact  our  sales  agent  or  the  sales 
person in charge.

 

Содержание VFL201A

Страница 1: ...MODEL VFL201A HDTV Analog I F LCD Color Viewfinder Operation Manual English...

Страница 2: ......

Страница 3: ...k accid1ent Do not allow any metallic or combustible material to enter or be dropped into the unit from an opening This may cause a fire or an electric shock accident Do not make any alterations to th...

Страница 4: ...he unit will maintain its performance in a stable manner for a long time it is recommended that a Periodic Inspection should be carried out Please consult with the sales person in charge for Periodic...

Страница 5: ...ausing a trouble or damage 13 Do not use this product for a space apparatus a nuclear energy controlling device or a medical instrument involved with human life Concerning the Quality of the OLED LCD...

Страница 6: ...ce of the viewfinder toward the sun Pay attention the direction of the eye piece relative to the sun when not looking into the eye piece for a period of time If the LCD panel gets burned Please contac...

Страница 7: ...ration Manual and the symbols and notations used in the manual Notes on the Manual This manual is written for readers with a basic knowledge of handing broadcast cameras The contents of this manual ar...

Страница 8: ......

Страница 9: ...enus VF MENU E 8 1 VF MENU 1 7 TOP MENU E 10 2 VF MENU 2 7 VF SETTING E 12 3 VF MENU 3 7 VIDEO SETTING E 13 4 VF MENU 4 7 PEAKING E 16 5 VF MENU 5 7 MARKER E 18 6 VF MENU 6 7 USER MARKER E 20 7 VF MEN...

Страница 10: ......

Страница 11: ...color display of 16 7 million colors 16 7 million colors 8bits color are achieved by a full color display and a high definition image is supplied Abundant peaking features This viewfinder supplies th...

Страница 12: ...an change the setting of a function which is assigned on the MENU The default function is MONO Mike holder fixation hole It is a screw hole to install the mike holder Diopter movement lever It is a le...

Страница 13: ...feature No NAME FUNCTION G TALLY It receives a G tally signal from the camera and the green LED lights up R TALLY TOP It receives a R tally signal from the camera and the red LED lights up BATT LED It...

Страница 14: ...g in the horizontal direction of VF after loosening the VF fixing knob 3 The VF connector is connected with the VF connector of the camera CAUTION Please pay attention to the direction of the connecto...

Страница 15: ...ce is turned anti clockwise and it will be detached Please take care that dust doesn t enter VF inside after detaching it The eyepiece installation Please align the mountain sign displayed in the root...

Страница 16: ...ion position 4 REVERSE SCAN ON OFF setting of REVERSE SCAN 5 COLOR TEMP Setting of color temperature 6 RGB YPbPr Setting of RGB YPbPr MENU 3 7 VIDEO SETTING 1 COLOR MONO Setting of COLOR MONO switchin...

Страница 17: ...r display level 3 SCENE SELECT Setting of five types of scenes RESET SCENEx Execution of resetting the setting scene display SCENEx Display of currently selected scene number MRK1 ON Setting of displa...

Страница 18: ...last MENU page when set tings were made in a previous ses sion will be displayed The initial MENU page displayed immedi ately after the power is turned ON will be PAGE 1 7 When PAGE is magenta color a...

Страница 19: ...to be made Turning OFF the MENU screen To erase the MENU press the MENU switch for long or by press EXIT for short While a User Marker is being drawn describing the User Marker can be performed By rot...

Страница 20: ...unctions to be assigned to Function Switches F1 to F3 Items that can be set up USRMRK ON OFF switchover of USER MARKER display TALLY OFF LOW HIGH setting of Front Tally SCR OFF SCREEN OFF function Lon...

Страница 21: ...restarts The screen saver function is not cancelled with moving video While the screen saver function is working the LED blinks After cancelling the screen saver function it may take a moment to stabi...

Страница 22: ...The default value is 0 V POSITION Sets up the adjustment of the image position for vertical direc tion The setting value is a value between 10 and 10 The default value is 0 REVERSE SCAN Sets up the Im...

Страница 23: ...over of CHROMA UP GAMMA SELECT Sets up the Gamma value The normal Gamma setting is 2 2 as a standard This is a function to increase the quality of the gradation in the dark sec tion in images by lower...

Страница 24: ...OP R TOP L BOTTOM L BOTTOM R BOTTOM RIGHT LEFT CENTER Above figure is the figure applicable when MAG RATIO x2 MAG RATIO It switches the magnification ratio of the screen The set values of x2 twofold x...

Страница 25: ...the video on the camera and the captured image is con ducted in the mode set in DISP INTERVAL Sets up the switchover interval between the captured image and the camera image in frame units The setting...

Страница 26: ...to attach to those portions that are difficult for edges to at tach because of a small difference in brightness In this case however peaking will attach even to the noise ele ments in the image Theref...

Страница 27: ...Peaking is ON the ON OFF setting for the function of varying the Peaking amount in conjunction with the zoom posi tion of the camera is carried out here The default value is OFF Setting ZM PEAK on a...

Страница 28: ...3 9 14 9 and 15 9 The default value is 4 3 SAFETY MARKER Switches the Safety Area of the Safety Marker The setting values that can be selected are between 80 and 100 set at the 1 increment The default...

Страница 29: ...r marker indication setting The default value is OFF MARKER COLOR Sets up the Marker Color The feature is in common with Aspect Marker Safety Marker Cross hatching Marker and Center Marker The setting...

Страница 30: ...the USER MARKER to be displayed from among SCENE1 through 5 The default value is SCENE1 Setting SCENE on a FUNCTION switch will enable switch over of individual SCENES of the USER MARKER RESET SCENE T...

Страница 31: ...h and that value can be decided by pressing the MENU switch Regarding the drawing items you can change them cyclically like below by turning the MENU switch SIZE H SIZE V POSI H POSI V Drawing for SIZ...

Страница 32: ...he vertical direction by turn ing the MENU switch And also ever time when you click the toggle switch F3 you can change the position movement unit to 1 or 10 pixels cycli cally How to use F1 and F2 to...

Страница 33: ...Displays the MPU version H W VERSION Display the Hard Ware version WORKING TIME Displays the accumulated Working Time in which the Viewfinder has been operated in increments of hours LOAD FACTORY Ret...

Страница 34: ...ayed Then if the MENU switch is continuously pressed for two seconds or so the MENU disappears and Valid Invalid operation of the FUNCTION switches is possible 2 When the MENU is displayed When the ME...

Страница 35: ...155 D mm not including protrusions and the mounting bracket 5 Mass 780 g or less 6 Accessories The mounting bracket 1 Operation manual 1 5 2 Rated performance 1 Camera video signal a Input terminal I...

Страница 36: ...Screen brightness Only LCD specification 220cd m 5 Drive method a TFT active matrix non interlace normally white 6 Pixel arrangement RGB vertical stripe 7 Response speed Ton Toff 16ms typ Ta 25 C 8 Co...

Страница 37: ...r function 1 Center marker Type A with a center intersection point Type B without a center intersection point 2 Safety marker a Types Safety area marker 80 100 5 5 division cross hatch 10 10 division...

Страница 38: ...rding to the difference of luminance The peaking will be effect for the pixels whose difference of luminance is low 4 ZOOM UP PEAKING The peaking amount can be variable by being linked with zoom posit...

Страница 39: ...nt with RoHS Directive Precautions Please understand that the specifications and the ap pearance of this product are subject to changes with out notice for improvements Missing or bright spots may occ...

Страница 40: ...JE 30 8 Exterior Drawing...

Страница 41: ...wah NJ 07430 U S A Phone 201 368 9171 FAX 201 569 1626 www Ikegami com Ikegami Electronics Europe GmbH Ikegami Strasse 1 D 41460 Neuss Germany Phone 02131 1230 FAX 02131 102820 www Ikegami de Ikegami...