17
1.
Select "ADJUST MODE" under the panel configuration menu.
2.
On the character indicator, "POS1" is indicated at the upper section and
"POS2" at the lower section.
3.
Align the IRIS position to the OPEN end and press the rotary switch.
("POS1" indicated at the upper section of the character indicator changes to "OK.")
4.
Align the IRIS position to the CLOSE end and press the rotary switch.
("POS2" indicated at the lower section of the character indicator changes to "OK.")
5.
Two seconds after both upper and lower sections of the character indicator
indicate "OK," the upper section changes to "EXE?" and the lower section
changes to "NO" on the indicator.
6.
When the rotary switch is rotated and operated, Yes and No can be switched. To
finalize the setting, select "Yes." To cancel, select "No." Then, press the rotary
switch.
7.
When "YES" is selected, execute the IRIS ADJUST setting. The panel restarts.
When "No" is selected, the panel returns to the top page of the panel configuration.