15
4.
Press the rotary switch and the setting of the selected item starts blinking.
5.
Next the setting can be changed by turning the rotary switch.
6.
When the desired setting is displayed, push the rotary switch.
7.
Exit the Panel Configuration menu by selecting Exit and pressing the rotary
switch. Or press the Knob Free switch and rotary switch simultaneously.
6.2 List of Panel Configuration Settings
Item
Function
Mode
IRIS MODE
Select
ABS(
Absolute value
control
),
REL(
Relative value
control
)
MPED RANGE
Select
STD, 1/2, 1/4, OFF
VR DISP
VR value display
*
ON, OFF
BUZZER
Select
STD, ATT, OFF
AVC SELECT
Select
1-2, 1-4
ADJUST MODE
IRIS operation position
adjustment function
USER MODE
Select
COMP, BASIC
RAM CLR
Select
MENU, ALL
EXIT
Menu mode Exit
* VR value display ON / OFF is, DNR · DEHAZE function only.
(M.PED · IRIS is no display)