background image

MKC-307 0710 VOL1(U)(E)

27

Inverse Mode 

Horizontal OFF 

Vertical OFF 

Date/Time Adjust 

Year 2007 

Mouth 1 

Day 16 

Hour 13 

Minute 00

„

Date/Time Adjust 

Sets up the date and time. 

*

 When the date and time have been set up, be sure to press the Select button before 

turning OFF the menu screen. 

„

Inverse Mode 

Sets up the flipping of the image constantly during normal shooting. 

[Horizontal] 

This is set to ON to flip the image horizontally as default. 

[Vertical] 

This is set to ON to flip the image vertically as default. 

Содержание MKC-307

Страница 1: ...MKC 307 Digital Process Compact 3CCD Color Camera Operation Manual...

Страница 2: ...are not responsible for any consequences caused by the following operations based on this manual x We are not responsible for the indemnification for any incidental damages such as those caused by mis...

Страница 3: ...y cause fire or an electric shock Do not modify this product It may cause fire or an electric shock Installation Do not place the product on an unstable surface It may fall or get damaged and cause in...

Страница 4: ...the product in spaces with high levels of humidity or dust or where greasy fumes or steam may come into contact It may lead to an electric shock Do not place the product near cooking tables or humidif...

Страница 5: ...Operation 18 Operation Procedure 18 Video Adjust 19 AE Mode 19 DTL Set 20 Field Frame 21 Auto Adjust 22 Scene File 22 Foot Switch Mode 23 Title 25 JPEG Parameter 26 Sound Level 26 Date Time Adjust 27...

Страница 6: ...gh the CAMERA cable FOCUS Connector Connects to the focus cable for optional microscope adapter CXA 301R The connector functions are described on the next page IRIS Connector Connects to the IRIS cabl...

Страница 7: ...filter or the optional filter may result in an incomplete focus It may also result in unexpected phenomena due to incidental light Removing them unnecessarily may lead to the loss of screws infrared...

Страница 8: ...is lens or microscope adapter capable of iris control is adjusted automatically or manually is selected It is normally used on its automatic setting When it is set to fixed the automatic manual iris v...

Страница 9: ...o the setting instantly before the image level indicator LED lights up red When the white balance button is pressed Auto White Balance is displayed on the monitor screen and white balance is executed...

Страница 10: ...he menu screen displayed the cursor is moved by the and buttons to select the item that you wish to set up To change the content of the item to set up the setting value is selected using and buttons U...

Страница 11: ...same functions can be assigned to the foot switch Please see Foot Switch Mode P23 for the menu screen for assignment Still screen The same function as Still Screen Still image saving Takes a still ima...

Страница 12: ...esults This image enhancement technology has been developed by Apical Limited Menu Button Displays the menu from which the user can set up the options on the monitor screen Select the item to be confi...

Страница 13: ...ape recorder or other similar devices through the DV terminal Please be sure to read Notes on DV connection on the next page when using DV OUT S VIDEO OUT Connector Outputs Y C VIDEO signals Connects...

Страница 14: ...ng the phase with the other system TRIGGER Connector Used to take in images in synchronization with the external trigger signal TRIGGER Connector HR10A 7R 5S 1 TRIGGER IN 2 IN RET 3 TRIGGER OUT 4 OUT...

Страница 15: ...optional RGB cable A commercially available D sub BNC x 5 cable can also be used In addition Y C output and VBS output are also available RGB Connector High density D sub15 pin female 1 R OUT 9 2 G O...

Страница 16: ...USB memory or USB HDD is connected to record still images and USB HDD to record moving images VGA Connector Connects to a VGA monitor Ground Terminal The system is grounded using this terminal when gr...

Страница 17: ...ct only outputs image signals and sound signals in DV format and does not have the function to exchange the control signals with external devices It may not operate properly depending on the connected...

Страница 18: ...used the last time1 when initialization is completed Be sure to turn OFF the POWER switch and disconnect the device from the mains supply and connection cables for the devices when moving the main un...

Страница 19: ...f a white subject on the screen Set the image level so that the white subject is not too bright on the screen and press the AWB button Auto White Balance will be displayed on the monitor screen and OK...

Страница 20: ...is equipped with various useful functions in its operation These functions can be selected and set up from the menu The basic operation procedure is provided as follows Operation Procedure 1 Pressing...

Страница 21: ...the black red and blue levels of the image Master Pedestal The master pedestal value can be adjusted using the and buttons This function is not used in normal conditions Gain Offset Red The red level...

Страница 22: ...he response speed for the electronic shutter and automatic sensitivity can be selected as either Middle Fast or Slow Peak Ratio Set The method of setting up the optical measurement for the electronic...

Страница 23: ...cement Button on the CCU front panel is turned ON can be selected It can be selected from 8 different colors flesh red orange yellow green cyan blue and magenta Skin DTL Gain The level of outline enha...

Страница 24: ...This adjustment will affect the camera image output adversely unless it is executed with the lens iris closed completely Under normal conditions there is no need to use this function Auto White Shade...

Страница 25: ...nd data cannot be saved on it Load Factory Default This function loads the default factory settings It is used to restore the settings when they have been changed and the initial status cannot be reco...

Страница 26: ...saving still image for mix Flip image flipped vertically Mirror image flipped horizontally and Rotate image flipped vertically and horizontally Foot Switch 3 The function for the third foot switch and...

Страница 27: ...ed Position The display position for the character string is selected from Top Left Top Right Bottom Left and Bottom Right Title Selects the character string to be displayed The characters that can be...

Страница 28: ...up for the quality of the still image to be recorded in the USB memory JPEG Factor JPEG quality is specified The highest quality is set at a value of 100 and the size being approximately 200KB Sound...

Страница 29: ...p the date and time When the date and time have been set up be sure to press the Select button before turning OFF the menu screen Inverse Mode Sets up the flipping of the image constantly during norma...

Страница 30: ...essed Mode The level of enhancement is selected from Low Middle and High Overlay Sets up the still image mix Lay Ratio The overlay ratio is set up Moving images are displayed at 100 size with the 0 se...

Страница 31: ...to ON to enable the trigger input Delay Fine Fine tuned external trigger input timing to camera shooting can be adjusted Delay Coarse Rough external trigger input timing to camera shooting can be adj...

Страница 32: ...t YUV 4 1 1 1 Channel DV Connector 6 pin Input Signal External Synchronization input VBS 1 0Vp p 75 BNC loop through BBS 0 4Vp p 75 Sound Input 60dBm mono Remote Input RS 232C 1 channel D Sub 9 pin ma...

Страница 33: ...ng Field frame switching possible from menu Still Screen Frame field switching possible from menu Color Correction paint R Bch r3dB Brightness Adjustment AE level Brightness adjustment possible by vol...

Страница 34: ...MKC 307 0710 VOL1 U E 32 5 Appearance Unit mm Camera Head CCU...

Страница 35: ...Issued by Ikegami Tsushinki Co Ltd The Whole or part of this manual may not be copied or reproduced by any means without permission from Ikegami Tsushinki Co Ltd The specifications and external appear...

Страница 36: ...an Phone 03 5700 1111 Fax 03 5700 1137 Ikegami Electronics U S A Inc 37 Brook Avenue Maywood New Jersey 07607 U S A Phone 201 368 9171 Fax 201 569 1626 Ikegami Electronics Europe GmbH Ikegami strasse...

Отзывы: