According to IEC regulations use for one-
phase connection: mains cable 3 x 4mm²
and for two-phase connection: mains
cable 4 x 2.5mm². Please respect specific
national regulations in the first priority.
• You must have the means for
disconnection incorporated in the fixed
wiring.
• You must have the connection and the
connecting links carried out as shown in
the connection diagram.
• The earth lead is connected to terminal
and must be longer than leads carrying
electric current.
• Secure the connecting cable with cable
clips or clamps.
Connection diagram
220V-240V 1N
220V-240V
N PE
L
400V 2N
220V-240V
220V-240V
N
L1 L2
PE
Insert the shunts between the screws as shown.
Main power connection 1-phase
Main power connection 2-phase
L
N
L1 L2 L3 N
Wiring colours:
Wiring colours:
Yellow / green
Yellow / green
N
Blue
N
Blue
L
Black or brown
L1
Black
L2
Brown
Tighten the terminal screws
securely!
Once you connect the hob to the mains,
check if all the cooking zones are ready to
use. Place a pot with some water on a
ENGLISH