Warning!
Do not use abrasive cleaners,
steel wool pads or acids, they will
damage the appliance.
To remove any food remains wash the enam-
elled elements, "caps" and "crowns", with
warm soapy water.
Stainless steel elements wash with water, and
then dry with a soft cloth.
This model is equipped with electrical ignition,
it is obtained through ceramic "candle" and
electrode.
Keep them well clean to avoid difficult light-
ning.
Periodically ask your local Service Centre
to check the conditions of the gas supply
pipe and the pressure adjuster, if it is fitted (this
service is not free of charge).
After cleaning, be sure to wipe dry with a soft
cloth.
What to do if…
Problem
Possible cause
Remedy
There is no spark when light-
ing the gas
There is no electrical supply
Check that the unit is plugged
in and the electrical supply is
switched on.
Check
the
house
electric
in-
stallation fuse.
Burner cap and Crown are
placed uneven
Check the burner cap and
crown have been replaced
correctly, e.g. after cleaning.
The flame is blowing out im-
mediately after lightning
Thermocouple is not heated
enough
After lightning the flame, keep
the knob pushed for about 5
sec.
The gas ring burns unevenly
Burner crown is blocked with
food residues
Check the main injector is not
blocked and the burner crown
is clear of food particles.
If there is a fault, first try to find a solution to
the problem yourself. If you cannot find a sol-
ution to the problem yourself, contact your
dealer or the After Sales Service.
If you operated the appliance wrongly, or
the installation was not carried out by a
registered engineer, the visit from the customer
service technician or dealer may not take
place free of charge, even during the warranty
period.
Technical data
Hob dimensions
width
290 mm
depth
510 mm
built in height
30 mm
Class Appliance: 3
Appliance Category: II2E+3+
Appliance gas supply: Natural gas G20/G25
(2E+) 20/25 mbar
ENGLISH