4
W710R008
W710R009
5
6
7
W710R010
9
8
8
24
Adjustment and replacement
Condenser
To remove
1 Drain the cooling system.
2 Drain the refrigerant system.
3 Disconnect all the radiator inlet and outlet
hoses.
4 Unclip and remove the radiator upwards.
5 Disconnect the condenser inlet fixing.
6 Remove nut from inlet pipe support bracket.
7 Disconnect the condenser outlet fixing.
8 Remove the 2 condenser fixing screws.
9 Lift condenser and out to remove.
To fit
Fit in reverse order.
Note
Use new O-rings on the end of the freon pipes.
Check compressor oil level.