www.ikancorp.com | 1.713.272.8822 | [email protected]
because we’re
filmmakers
too
Periodic Fixture Inspection
1. The condition of the internal wiring and ceramic base will need to be inspected and tested every 4000 working hours or at least once a year. This
frequency may need to be increased if the fixture has endured rough treatment. All internal components should only be replaced with Lightstar
spare parts.
2. The lamps should be checked every 100 working hours. The lamp should be changed if the lamp becomes deformed or damaged, otherwise
explosion might occur. Defer to instructions provided by the lamp manufacturer.
3. Always check the safety shield before every use.
4. All high-voltage components (ex: voltage wires, lamp ceramic, external shield, igniter must be inspected every 100 working hours or at least once a
year.
5. Outer door hinges and latching system must be checked every 250 working hours to ensure proper seating of the safety shield. This will allow
inspections of accessories and the holding clamps.
6. The condition of the internal mirror must be maintained every 250 working hours. It must be replaced whenever it becomes either cracked or
broken. It is essential for the performance of the fixture.
Specifications & Photometrics
LSC-006 Specifications
Beam Angle
6° to 58°
Build Material
Aluminum
Color Temperature
5600K
Cooling System
Air Cooled
Fixture Size
36.6 x 27.5 x 24.2 in.
Fixture Weight
85 lbs
Focusing
Knob Control
Head Type
HMI Fresnel 6000W
IP Class
IP23
Lamp Base
6000W / 125V / G38
Lens Size
Fresnel 16.5"
Yoke
Cast Aluminum with 1 1/8" Pin
LUX
METERS
10M
15M
20M
42500
18890
10625
LUX
METERS
10M
15M
20M
2650
1178
663
FC
FEET
32.8'
49'
65'
3948.4
1754.9
987.1
FC
FEET
32.8'
49'
65'
246.2
109.4
61.6