Ikan LS-575SPX Скачать руководство пользователя страница 4

FAQ’s & Answers

1.  The required ballast input voltage can automatically match the AC power. 

A. Lightstar electronic ballasts can be used with either 110V or 220V AC power. 

2.  If the ballast suddenly stops working after working for some time. 

A. The lamp itself is broken, or end of life. 
B. The ballast fan may be bad; in this case the user must wait for the ballast temperature to  
     cool down before starting the unit again. 
C. If the AC voltage exceeds the specified input voltage on the ballast this will cause the  
    breaker to engage. 
D. An unexpected surge/spike of electricity will cause the ballast protection circuit to engage  
    and cause the ballast to not function. 
E. If the ballast stops working due to voltage surge/spike its best to turn off the ballast than  
    turn the breaker back on and push the Action/Close button. These will reactivate the  
    ballast for reuse.

Product Accessories

Lightstar 575W Super Spot HMI Lighting Fixture

5 Sets of Lens to adjust the Beam Degree and Angle

No Lens Beam Angle:    

5 Degree

Spot Lens Beam Angle:  

9 Degree

Narrow Flood Beam Angle: 

11 - 22 Degrees

Flood Beam Angle: 

 

21 - 41 Degrees

Super Flood Beam Angle: 

42 Degrees

Frost Beam Angle:  

 

35 Degrees

Lighting Illumination Steps

Check the start button on the operation panel “0” so that it is in the pressed down position.

The fixture to ballast cable is connected and locked into place.

Connect the ballast power plug to the AC Power.

After the above operations are correct, the start button on the operation panel “1” is pressed, so that it’s in the ON position.

When the AC power voltage is live, the voltage indicator will be illuminated with a Green light.

Output Power Adjustment

The HMI Bulb is installed.
The power and output of the lamp can be adjustment by dimming the operating knob on the front panel.
Power can be adjusted between 50% and 100% on the ballast. 