background image

10

11

1

IKA MATRIX ORBITAL DELTA PLUS

2

Mains cable

3

User guide

4

Warranty card

5

USB cable

Unpacking

›  Please unpack the device carefully�
›  Any damage should be notified immediately to the shipping agent (post office, railway 

network or logistics company)�

IKA

 MA

TRI

X O

RBI

TA

L D

elta 

+

Gar

ant

y

1+2+3

1

2

3

4

5

Operator panel and display

A
B

C

G H I

J

K

L

N

D

E F

M

O

/// Explanation of the control elements

Item

Designation

Function

A

Graph button

Enter the graph (Speed / Time / Temperature) menu�

B

Temperature (+) button

Increase the temperature setting�

C

Temperature (-) button

Decrease the temperature setting�

D

Tempering button

Start / stop the tempering function�

E

Timer button

Enter the timer menu�

F

“Programs (Prog�)” button

Enter the programs menu�

G

“Menu“ button

Touch it once: main menu is displayed�
Touch it a second time: back to the working screen�

H

“Back“ button

Return to the previous menu level�

I

Pause (

II

) button

Touch it once: Pause the mixing and tempering function�
Touch it a second time: Restart the mixing and tempering function�

J

Mixing button

Start / stop the mixing function�
Confirm the select menu option in menu / sub-menu�

K

Speed (-) button

Decrease mixing speed setting�
Menu navigation in menu / sub-menu�

L

Speed (+) button

Increases the mixing speed setting� 
Menu navigation in the menu / sub-menu�

M

“Quick mix“ button

Keep touching it: Start the „Quick mix“ function with the set speed�
Release it: Stop the „Quick mix“ function�

N

Lock button

Lock / unlock the buttons�

N

Display

Screen�

Содержание MATRIX ORBITAL DELTA PLUS

Страница 1: ...IKA MATRIX ORBITAL DELTA PLUS...

Страница 2: ...2 3 ENGLISH...

Страница 3: ...rning symbols 6 Safety instructions 7 Unpacking 10 Operation 17 Intended use 9 Technical Data 38 Interfaces and outputs 31 Warranty 39 Maintenance and cleaning 37 Accessories 37 Operator panel and dis...

Страница 4: ...arting up and follow the safety instructions Keep the operating instructions in a place where it can be accessed by everyone Ensure that only trained staff work with the device Follow the safety instr...

Страница 5: ...foreign objects liquids and other contaminants Never use tubes made of glass or other fragile material Glass tubes can be smash Only use sealed micro test tube and sealed microplate deepwell plate Th...

Страница 6: ...empering function E Timer button Enter the timer menu F Programs Prog button Enter the programs menu G Menu button Touch it once main menu is displayed Touch it a second time back to the working scree...

Страница 7: ...temperature reached see Tempering under Timer Timer Counter symbol Mixing Indicate the Timer Counter for mixing Mixing symbol Indicate the mixing function is activated 00 10 Mixing in Intermittent mod...

Страница 8: ...14 15 Inserting the deepwell plate DWP microplate MTP Inserting the micro test tubes Attaching the exchangeable attachments 1 2 1 2 1 Click 3 2 A B C D E F G H 1 2...

Страница 9: ...een established with the device by pressing down the button the heating function can prevent the formation of condensate Operation Switching on IKA MATRIX ORBITAL Delta Version 1 02 003 1 01 021 Shake...

Страница 10: ...tual rpm 25 1 0 300 0 00 00 0 00 01 38 0 LIMIT 1 0 LIMIT 100 0 0 00 00 99 59 59 25 0 38 0 max Setting the speed and starting mixing A IKA MATRIX 2 0 mL Fast actual C Set C Set rpm actual rpm 38 0 38 0...

Страница 11: ...s 3 3 3 3 3 3 F F F F s s s s s s s s 2 2 2 Restarting the tempering and mixing function Note During the pause status the tempering mixing function can be switched off separately by touching temperin...

Страница 12: ...0 mL Fast actual C Set C Set rpm actual rpm 38 0 38 0 500 500 0 00 39 0 00 50 A IKA MATRIX 2 0 mL Fast actual C Set C Set rpm actual rpm 38 0 500 0 00 40 0 00 51 38 0 500 Unlocking the buttons 1s A I...

Страница 13: ...0 Fast 0 00 00 10 00 00 0 500 Quick mix Note When the tempering function is activated the Quick mix function is not available Press the Menu button G Select right menu item by touching the speed butt...

Страница 14: ...ed and CW time Stop time is set Note CW time and Stop time can be set separately CCW 0 CW 300 rpm time 300 CCW Intermittent mode is activated and CCW time Stop time is set Note CCW time and Stop time...

Страница 15: ...atically executed In control mode x x K The hysteresis tolerance of the actual temperature to target temperature is set e g 0 1 K The target values and settings of the segment are valid until the actu...

Страница 16: ...t C or F for the temperature A check mark indicates the unit that is set for the system Display In the Background menu option you select black or white color for the working screen In the Firmware Upd...

Страница 17: ...ed to the WD safety temperature limit value The error message Error 2 is displayed The above details correspond as far as possible to the recommendations of the NAMUR working party NAMUR recommendatio...

Страница 18: ...ons between device and external devices PC 1 1 Cable This cable is required to connect RS 232 port to a PC 1 2 RxD 3 TxD 4 5 GND 6 7 RTS 8 CTS 9 1 RxD 2 TxD 3 4 GND 5 6 RTS 7 CTS 8 9 PC 1 2 3 4 5 6 7...

Страница 19: ...r error code is displayed then take one of the following steps Contact the service department Send the device for repair including a short description of the fault Error 49 Motor hall sensor fault Err...

Страница 20: ...e delivery invoice and giving reasons for the claim You will be liable for freight costs The warranty does not cover worn out parts nor does it apply to faults resulting from improper use insufficient...

Страница 21: ...sales england ika com MALAYSIA IKA Works Asia Sdn Bhd Phone 60 3 6099 5666 eMail sales lab ika my CHINA IKA Works Guangzhou Phone 86 20 8222 6771 eMail info ika cn POLAND IKA Poland Sp z o o Phone 48...

Отзывы: