Unpacking

›  Please unpack the device carefully�
›  Any damage should be notified immediately to the shipping agent (post office, railway net-

work or logistics company)�

1

IKA G-L

2

Rotor cover

3

Rotor nut

4

Rotor IKA CR 12 x 2 ml

5

Technical information IKA G-L Rotors

6

Power cord set

7

USB cable

8

User guide

9

Warranty card

Operator panel and display

-L

A

B

C

D

E

F

G

J

K

H

I

L

M

N

O

P

Q

R

A

On/Off button

Switch on/off the device�

B

“Pulse” button

Short-term centrifuging (device runs at max� or set speed as long as 
the button (B) is kept pressing)�

C

“rcf/rpm” (-) button

Decrease the “rcf/rpm” setting value�

D

“rcf/rpm” (+) button

Increase the “rcf/rpm” setting value�

E

“rcf/rpm” button

Switch between “rcf” and “rpm” function�

F

Timer (-) button

Decrease the timer setting value�

G

Timer (+) button

Increase the timer setting value�

H

“C/T” button

Switch between counter (C) and timer (T) function�

I

“Program (Prog�)” button

Select the program�

J

“Start/Stop” button

Start/stop to run the device�

K

Lid release

 

button

Open the safety lid of the device�

L

Program number display

Display the selected program number�

M

“counter/timer” display

Display the counter/timer value�

N

“timer” indicator

Indicate the timer function is activated�

O

“counter” indicator

Indicate the counter function is activated�

P

“rcf/rpm” display

Display the “rcf/rpm” value�

Q

“rpm” indicator

Indicate the “rpm” function is activated�

R

“rcf” indicator

Indicate the “rcf” function is activated�

Tch

nic

al I

nfo

rma

tion

IKA

 [sc

ale

]

Gar

ant

y

1+2+

3

-L

1

2

4

6

8

9

7

+

5

3

Содержание G-L

Страница 1: ...IKA G L...

Страница 2: ...2 3 ENGLISH...

Страница 3: ...Explication of warning symbols 6 Safety instructions 7 Unpacking 10 Operation 14 Error codes and troubleshooting 20 Intended use 9 Technical Data 26 Interfaces and outputs 24 Warranty 27 Maintenance a...

Страница 4: ...ed by everyone Ensure that only trained staff work with the device Follow the safety instructions guidelines occupational health and safety and accident prevention regulations The device must only be...

Страница 5: ...th pathogenic micro organisms the user should take appropriate precau tions In such cases centrifuging vessels with special screw seals for hazardous substances must always be used For materials in ri...

Страница 6: ...setting value E rcf rpm button Switch between rcf and rpm function F Timer button Decrease the timer setting value G Timer button Increase the timer setting value H C T button Switch between counter C...

Страница 7: ...12 13 Installation 1 2 2 3 4 5 1 2 6 7 8 CLICK 9 CLICK 10 300 mm 300 mm 300 mm 300 mm L L 1 2 B 1 220 240 V 50 60 Hz 92 W...

Страница 8: ...x maximum centrifugation radius in cm Example The maximum centrifugation radius of the rotor IKA G L CR 12x2ml is 6 cm At a speed of 15700 rpm a maximum g force of 16500 x g can be achieved Switching...

Страница 9: ...desired rpm with rcf rpm button D rcf rpm button C Open the lid by pressing lid release button K Press and hold Pulse Button B Toggle between max speed 157 and set speed SET by long press on pulse but...

Страница 10: ...18 19 Editing the program 1 2 3 1 4 2 3 Activating the program 1 2 3...

Страница 11: ...he device with the power switch and allow it to cool down Restart the device by pressing power switch Causes Rotor nut is not attached or not properly attached Effect motor off Solutions Switch off th...

Страница 12: ...ial number see type plate item and designation of the spare part see www ika com spare parts diagram and spare parts list software version Briefly visible in the display when the device is switched on...

Страница 13: ...the computer automation system Commands are transmitted in capital letters Commands and parameters including successive parameters are separated by at least one space Code hex 0x20 Each individual com...

Страница 14: ...g time from max speed s 18 Speed display LED Speed setting Buttons Speed setting resolution rpm 1 x100 Max density g ml 1 2 Timer function Timer range 20 seconds 99 minutes 59 seconds Timer display LE...

Страница 15: ...TD Phone 44 1865 986 162 eMail sales england ika com Malaysia IKA Works Asia Sdn Bhd Phone 60 3 6099 5666 eMail sales lab ika my CHINA IKA Works Guangzhou Phone 86 20 8222 6771 eMail info ika cn POLAN...

Отзывы: