25
2022/06/06 12:57
REP. : 99.8%
2022/06/06 13:00
O2: 0.06% CO2:22.3%
2022/06/06 13:10
O2: 0.89%
2022/06/06 13:20
O2: 0.07% CO2:20.3%
---------------- ALL DATA ----------------
001 20
22/06/06
13:20
O2: 0.07% CO2:20.3%
002 20
22/06/06
13:10
O2: 0.89%
003 20
22/06/06
13:00
O2: 0.06% CO2:22.3%
004 20
22/06/06
12:57
REP. : 99.8%
005 20
22/06/05
12:55
O2: 0.07% CO2:27.0%
006 20
22/06/05
10:50
O2: 0.09%
------------------ END -----------------
Connecting to an external device
(Serial communication)
Connecting a printer
The measurement data can be printed out by connecting a printer (optional, sold
separately). A printer cable is required to connect the printer. (RS-232C serial cross cable
25-pin male to 9-pin female)
1.
Refer to page 15 and set the output setting destination to “PRINTER”.
2.
Connect the PACK LEADER and printer.
3.
Press
on the Measurement Complete screen.
The measured values will be saved in the memory and simultaneously printed out one item.
Connecting to a personal computer
The measurement data can be read and the devices can be
controlled by connecting to a personal computer (prepared by
the user). A serial cross cable (RS-232C) is required, and the
personal computer must have a serial terminal (RS-232C). If the
personal computer does not have a serial terminal, prepare a
USB to RS-232C converter.
1.
Refer to page 15 and set the output setting destination to “PC”.
2.
Connect the PACK LEADER and personal computer.
3.
Refer to the following table and set the communication settings.
[Communication settings]
Item
Setting
Baud rate
9600bps
Data length
8bit
Stop bit
1bit
Parity
None
*
Contact the dealer from which you purchased the product for details on the out-
put measurement data and main unit control specifications.
O
2
replacement rate
O
2
, CO
2
measurement value
O
2
measurement value
(When CO
2
disable display setting is set to “ON”)
Printing all of the saved data
When the Measurement Standby screen is displayed, press
.
The HISTORY screen will open.
When
is held down for 3 seconds or longer, all saved data will be printed out.
The data is printed from the latest data.
• Press
to forcibly stop the printing.
[Example of printing]