Appendix F: Specifications 

Power 

Voltage 

90-240VAC-0.5A-47-63Hz/5VDC-2000 mA 

Power required 

Repeater/ Cross- Repeater Unit : max. 5V/750mA 
operation mode CATx – Repeater: 

ca. 500mA 

operation mode Fiber Repeater 

ca. 300mA 

operation mode Cross Repeater 

ca. 750mA 

Interface 

(Depending on type of device) 

LC 

Multimode or Singlemode – depending on device 

RJ45 

1000 MBit high speed transmission. Wiring according 
to EIA/TIA 568B Gigabit Ethernet.  

Maximum Length of Interconnection Cable (CATx) 

CATx Installation cable AWG24 

140m (400ft) 

CATx Patchcable AWG26/8 

70m (200ft) 

Type of Interconnection Cable (CATx) 

CATx Installation cable AWG24 

S/UTP (Cat5) cable acc. EIA/TIA 56A, TSB 36 or 
Digital STP 17-03170. Four pairs AWG 24. Wiring 
acc. EIA/TIA 568A (1000BaseT). 

CATx Patchcable AWG26/7 

S/UTP (Cat5) cable acc. EIA/TIA 56A, TSB 36 or 
Digital STP 17-03170. Four pairs AWG 26/7. Wiring 
acc. EIA/TIA 568A (1000BaseT). 

Содержание K471-CM

Страница 1: ...e distance and simultaneously convert from one medium to another e g CATx to Multimode This manual will tell you all about your new Repeater Cross Repeater including how to install operate and troubleshoot it For an introduction to the Repeater Cross Repeater see Chapter 2 The Repeater Cross Repeater product codes covered in this manual are Repeater Devices K471 CT CATx Repeater to double the dist...

Страница 2: ...r does the manufacturer assume any liability for damages resulting from the use of the information contained herein The manufacturer reserves the right to change the specifications functions or circuitry of the product without notice The manufacturer cannot accept liability for damage due to misuse of the product or due to any other circumstances outside the manufacturer s control whether environm...

Страница 3: ...EMPTY PAGE Rev 09 25 2012 3 ...

Страница 4: ...mentation noted in this manual shall be considered in detail The length of the attached CPU or Console Cables must not exceed 3m The use of suggested interconnect cables is mandatory Oberteuringen June 23 rd 2009 The management manufacturer IHSE GmbH Maybachstrasse 11 88094 Oberteuringen Germany WARNING This equipment has been found to comply with the limits for a Class A digital device pursuant t...

Страница 5: ...airflow Do not place a power supplies directly on top of a unit Do not obstruct a unit s ventilation existing holes To safeguard against personal injury and avoid possible damage to equipment or property please observe the following Only use power supplies originally supplied with the product or manufacturer approved replacements Do not attempt to dismantle or repair any power supply Do not use a ...

Страница 6: ...e 11 3 Installation 12 3 1 Package Contents 12 3 2 Interconnection Cable Requirements 13 3 3 System Setup 14 3 4 Device Views 15 3 5 Diagnostics 16 4 Service Setup 17 4 1 Setup at the Repeater Cross Repeater 18 4 2 installation instruction 19 5 Troubleshooting 21 Appendix A Example Applications 22 Appendix B Rack Mount Options 25 Appendix D Calling Technical Support 27 Appendix F Specifications 28...

Страница 7: ...escribed in the rest of this manual Install system 1 Connect Local unit to CPU or switch 2 Connect Local unit to Repeater and Repeater to Remote Unit using matching interconnection cable CATx or Fiber 3 Connect Remote unit to KVM 4 Power up the system Done YES NO Link LED illuminated NO YES Check p s u s and connection to power outlet Power LED illuminated Check the CATx Fiber cable and CATx Fiber...

Страница 8: ... possible 2 2 Glossary The following terms are used in this guide CATx Any Category 5 5e 6 or higher cable solid wires type AWG24 Fiber Singlemode or Multimode fiber cable Singlemode 9µ Singlemode fiber cable Multimode 62 5µ Multimode or 50µ Multimode fiber cable KVM Keyboard Video and Mouse Console Keyboard Mouse and Monitor Singlehead An extender system that supports one monitor Keyboard Mouse D...

Страница 9: ...OVERVIEW Rev 09 25 2012 9 2 3 Example of a Repeater Cross Repeater System Installation as Repeater to double the total allowed distance Installation as Cross Repeater for inhomogeneous cable path ...

Страница 10: ...ide of the Repeater Cross Repeater may have the usual maximum distance e g CATx up to 140m Multimode 50µ up to 400m Attention actually DVXi CATx and Fiber devices must not be used assorted This means it s not allowed to connect a DVXi CATx Local Unit with a DVXi Fiber Remote Unit So actually Cross Repeater can be used only in pairs For Dual Head devices you need two pieces Repeater one for each of...

Страница 11: ...l Cross Repeater to convert from 2x CATx to 2x Singlemode or back K471 MS Multimode Singlemode Cross Repeater to convert from Multimode to Singlemode or back Zubehör 473 5G 19 1HE Rackmout Kit to mount up to 5 devices 473 1K Mounting plate to mount by screws 473 2K Mounting plate to mount by snap on 2 6 How to Use This Guide This guide describes the installation and configuration of the Repeater C...

Страница 12: ... you to identify and solve any cabling problems and experiment with the Repeater Cross Repeater more conveniently 3 1 Package Contents You should receive the following items in your extender package all types Repeater Cross Repeater 5V DC universal power supply German type power cord User manual Quick Setup If anything is missing please contact Technical Support see Appendix F Calling Technical Su...

Страница 13: ...Dualhead devices Please note that the allowed distance will depend on device type AND on used fiber type Recommended cables Multimode type 50 125µ allowed distance app 400m 1 300ft Multimode type 62 5 125µ allowed distance app 200m 650ft Singlemode type 9 125µ allowed distance app 10km 32 750ft A point to point connection is required Having one or more patch panels in the line is possible and allo...

Страница 14: ... this please refer to installation instruction on page 19 If you have bought a Dual Cross Repeater your device will have two CATx connectors and two fiber connectors The units are marked as Local or Remote For a correct installation please refer to installation instruction on page 19 If you want to upgrade a Cross Repeater to Dual Cross Repeater you need to reconfigure the jumper settings To do th...

Страница 15: ...STALLATION Rev 09 25 2012 15 3 4 Device Views Repeater Cross Repeater CATx view Repeater Cross Repeater Fiber view To Local Unit To Remote Unit 5V universal switch mode p s u To Local Unit To Remote Unit ...

Страница 16: ... the LEDs is shown below Diagnostic LEDs at the Repeater Cross Repeater LED Appearance Diagnostics Power LED Red LED Off On Device not ready Device ready Link Status Green LED Blinking On No INTERCONNECT connection via CATx or fiber cable Device ready Data Error Green LED Indicator LED actually without function Diagnostic LED Data Error Diagnostic LED Link Status Diagnostic LED Power Diagnostic LE...

Страница 17: ...ssary to setup configuration specials For some applications you may need to open the Local Unit and or the Remote Unit Unscrew the Philips type screws at both sides at the bottom of the device Unscrew the UNC type screws at both sides of the monitor connectors Carefully displace the lower and upper shells of the case Fastening screw on the bottom of the device Fastening screw on the bottom of the ...

Страница 18: ...ight eventually not equipped with GBICs The main PCB then will look like this Use the diagram to locate jumpers Operating mode Repeater or Cross Repeater If you want to alter the mode of operation after the date of purchase e g from Repeater to Cross Repeater or vice versa you need probably to install optical Transceiver GBICs and reconfigure the device Operating Mode JP1 JPA B Repeater or Fiber C...

Страница 19: ... B Dualhead Cross Repeater Local CATx Dualhead Cross Repeater Remote CATx 4 2 installation instruction Basically you need to pay attention to attach at connectors marked with A only cables which link to a Local Unit and to attach at connectors marked with B only cables which link to a Remote Unit CATx or Fiber Repeater Multimode Singlemode Cross Repeater The Local Unit is connected via CATx Fiber ...

Страница 20: ...Cs in your devices are plugged incorrect you may alter the configuration easily flap the shackle at the GBIC downwards now pull the GBIC using the shackle out of the cage plug the GBIC with soft force into the other cage until it snaps into place flap the shackle at the GBIC upwards to lock the GBIC Do not try to pull the GBIC out of the cage while the shackle remains in the lock position not flap...

Страница 21: ...tion where the CATx cable link to the Remote Unit 5 Troubleshooting Monitor There isn t a picture Check the power supply connection at the local and remote unit and at the Repeater Cross Repeater Is the Power Red LED at the devices illuminated see page 15 If not the internal power supply may be damaged or there may be an internal error Check that the INTERCONNECT cable is connected at the Local Un...

Страница 22: ...25 2012 Appendix A Example Applications This section illustrates some specific applications using the Repeater Cross Repeater Repeater in Industrial Plant to raise the allowed distance of the interconnection Repeater in Industrial Plant ...

Страница 23: ...nments especially public buildings the signal path may be inhomogeneous This means a part might be based on CATx another part in Multimode The Cross Repeater hereby allow to convert from one medium to another without laborious regaining the original signals and resending them Cross Repeater in public building ...

Страница 24: ...of two buildings with CATx Cables Because of this the interconnection must be done in fiber A server from the server room shall be connected with the user console in the plant The Cross Repeater hereby allow to convert from one medium to another without laborious regaining the original signals and resending them Cross Repeater for interconnection of two buildings ...

Страница 25: ...requires 1U Rackspace Blindplates in the list of parts delivered allow to cover unused device positions Rackmount Kit 473 5G List of parts delivered Mounting instruction Align the holes on the base plate with the vacant screw holes on the base of the device Fasten the base of the unit to the plate of the mounting kit Only use the supplied short screws to prevent damages on the PCB s Close the rema...

Страница 26: ...ackmount Kit 473 5G allows to mount a different count of devices 1 5 pieces Einbau 1 Gerät mounting 1 device Einbau 2 Geräte mounting 2 devices Einbau 3 Geräte mounting 3 devices Einbau 5 Geräte mounting 5 devices Einbau 4 Geräte mounting 4 devices ...

Страница 27: ...ccurs The components involved in the problem that is what type of computers what type of keyboard brand of mouse make and model of monitor type and make of cable etc Any particular application that when used appears to create the problem or make it worse The results of any testing you ve already done To solve some problems it might be necessary to upgrade the Extender s firmware If this turns out ...

Страница 28: ...de depending on device RJ45 1000 MBit high speed transmission Wiring according to EIA TIA 568B Gigabit Ethernet Maximum Length of Interconnection Cable CATx CATx Installation cable AWG24 140m 400ft CATx Patchcable AWG26 8 70m 200ft Type of Interconnection Cable CATx CATx Installation cable AWG24 S UTP Cat5 cable acc EIA TIA 56A TSB 36 or Digital STP 17 03170 Four pairs AWG 24 Wiring acc EIA TIA 56...

Страница 29: ...de 50µm 400m 1 300ft Multimode 62 5µm 200m 650ft Size and Shipping Weight Repeater Cross Repeater 80 x 110 x 29mm 3 x4 3 x1 1 Weight 0 2kg 0 6lb Shipping box 165x165x110mm 6 5 x6 5 x4 3 Weight 0 6 kg 1 3lb Environmental Operating Temperature 41 to 113 F 5 to 45 C Storage Temperature 13 to 140 F 25 to 60 C Relative Humidity max 80 non condensing ...

Страница 30: ...v 09 25 2012 Appendix G Connectors Repeater Cross Repeater Connector Pin outs Power Supply Pin Signal inner 5V outer GND CATx Interface Pin out according to EIA TIA 568A 1000BaseT Pin Pin 1 D1 5 D3 2 D1 6 D2 3 D2 7 D4 4 D3 8 D4 1 8 ...

Страница 31: ...NOTES ...

Отзывы: