Draco tera
90
2014-04-15
Field
Selection
Description
activated
If a console is not connected to a CPU,
you can establish an automatic
connection to the next available CPU by
hitting any key or mouse button.
CPU Auto
Connect
deactivated Function not active (default)
CPU Timeout
0 – 999
minutes
Period of inactivity after which a console
will be automatically disconnected from
its current CPU (default value:
0 minutes)
activated
Activate request of K/M control by
keyboard event (key will be lost)
Keyboard
Connect
deactivated Function not active (default)
activated
Activate request of K/M control by mouse
event
Mouse
Connect
deactivated Function not active (default)
Release Time
0-999
seconds
Period of inactivity of a connected
console after which K/M control can be
requested by other consoles connected
to the CPU.
Note:
Set "0" for an immediate
transfer in real-time.
Only one console can have
keyboard and mouse control at the
same time. The other consoles that
are connected to the same CPU
have a video only status (default
value: 10 seconds)
If the
Keyboard Connect
and/or
Mouse Connect
options are activated,
the
Release Time
condition will have to be met until a new user will gain
control.