Operation
2017-03-31
35
6.1.3
Optimization of Picture Settings
Should Auto Configuration fail to provide the optimal picture, it can be
adjusted manually by following this procedure:
1. Select 'Picture Settings' in the main menu.
2. Modify the values in the menu items 'Clock' and 'Phase' until all
picture corruption has disappeared.
3. If the picture is displaced:
–
Select the menu item 'Display position' in the main menu item
'Output Settings' and position the picture in the upper left corner
of the monitor.
–
Select the menu items 'Width' and 'Height' in the main menu item
'Picture Settings' and modify the values for width and height of
the picture until the monitor is completely filled by the picture.
4. Exit the OSD.
A window appears to save settings. This can take a few seconds.
5. Save the settings.
Pos: 23 /806-IHSE/Betrieb/Laden von DDC-Informationen/484-xx @ 12\mod_1410274086726_6.doc @ 149709 @ 2333 @ 1
6.2
Download of DDC Information
Loading DDC information is only relevant if you want to connect a VGA
source. By default, the factory DDC information is reported to the source
(computer, CPU). If these settings do not lead to a satisfying result, the
DDC information of the connected monitor can be downloaded and stored
internally.
There are two options to load the DDC information of the connected
monitor:
By means of a keyboard connected to the KVM extender CON Unit
(see Chapter 6.2, Page 35).
By means of the 'Read DDC' command in the OSD (see Chapter 6.2,
Page 35).