background image

SAFETY / LISTING LABEL - WCT6820WS

IHP 15-22848

CLEARANCES TO COMBUSTIBLES:

SIDE 

W

ALL (FROM DOOR EDGE)

 

24 in. (610 mm)

MANTEL (ABOVE FIREPLACE’S BASE)

 42 in. (1067 mm)

BACK 

W

ALL (FROM S

PACERS)

 

0 in. 

 (0 mm)

ABOVE THE FIREPLACE (FROM 

      THE BASE OF THE FIREPLACE)

 

6 ft. 8 in. (2032 mm)

)

m

15(

  .

ni 

2

 Y

EN

MI

HC

DÉGAGEMENTS AUX COMBUSTIBLES:

MUR L

ATÉRAL (DE 

L’OUVE

RTURE DE LA PO

RTE)

 

24 po.

 (610 mm)

LINTEAU (AU-DESSUS DE LA BASE DU FOYER)

 

42 po.

 (1067 mm)

MUR ARRIÈRE ET CÔTÉ DU FOYER (DES ES

PACEURS)

 0 po. 

 (0 mm)

AU-DESSUS DU FOYER (À 

PA

RTIR DE LA BASE 

)

m

23

02(

 .

op 

8 .i

6

 )

RE

YO

UD 

    

 

)

m

15(

  .

op 

2

 E

ÉNI

ME

HC

LISTED 

FACTO

RY BUI

LT FIREPLACE

FOYER PRÉ

FABRIQUE HOMOLOGUÉ

P/N 900433-00, REV. 0, 05/2015

IGN 15-22848

DA

TE OF MFG.

1     

2     

3     

4     

5     

6     

7     

8     

9    

10

    

11

    

12

         

2019-20-21-22-23-24-25

INS

TALL WITH MINIMUM CLEARANCES TO 

W

ALL 

AS SHOWN IN INCHES.

SIDE

W

ALL - BACK

W

ALL

INS

TALL

ATION

0”

0”

FIREPLACE

FRONT

CORNER INS

TALL

ATION

0”

0”

FIREPLACE

FRONT

FLOOR PROTECTOR MINIMUM DIS

TANCE 

FROM OPENING IN INCHES

HEA

RTH EXTENSION M

ATERIAL :

-   

 3/8 “ THICKNESS NON COMBUSTIBLE 

M

ATERIAL

-   

 OR EQUI

VALENT

FIREPLACE

FRONT

18”

36”

FIREPLACE, ALSO FOR USE IN MANU

FACTURED 

HOMES WITH SOLID FUEL ON

LY

CE FOYER EST ÉGALEMENT CE

RTIFIÉ POUR 

INS

TALL

ATION DANS LES MAISONS MOBILES. 

COMBUSTIBLES SOLIDES SEULEMEN

T.

Conforms to / Conforme au :  UL STD 127

Certified to / Certifié au :   ULC STD S610

Serial No. Numéro

 de

 séri

e

Model / Modèle:

 

WCT6820WS

Report No. / Rapport nº

14-199

C

US

Manufactured by / Fabriqué par: INNOVATIVE HEARTH PRODUCTS

1502 14th St. NW

Auburn, 

W

A  98001 USA

Certification test emission value 3.7 g/hr per 2015 standard Valeur d’émission du test d’homologation 3,7 g/h selon la norme 2015

U.S. ENVIRONMEN

TA

L PROTECTION

 AGENCY

Certified to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020.

• 

USE WOOD FUEL ON

LY

• 

NON COMBUSTIBLE HEA

R

TH EXTENSION MUST BE 

INS

TALLED 

AT FRONT OF UNIT EXTENDING 18 in. 

(457 mm) 

AT FRONT AND 36 in. (914 mm) WIDE 

MINIMUM .

• 

THIS FIREPLACE HAS NOT BEEN TESTED WITH  UNVENTED GAS LOG SE

T. TO REDUCE RISK OF 

FIRE OR INJU

R

Y DO NOT INS

TALL AN UNVENTED 

GAS LOG SET INTO THE FIREPLACE.

• 

ELECTRICAL R

ATING:  120 

V, 60 Hz

• 

CHIMNEY TYPE: USE ON

LY WITH LISTED 6 in. 

DIAMETER CHIMNE

Y, CE

R

TIFIED MODEL ASHT+, 

S-2100+, , OR AC.

• 

CAN BE CONNECTED TO A MASON

R

Y CHIMNEY AS 

DESCRIBED IN THE INS

TALL

ATION INSTRUCTIONS.

• 

COMPONENTS USED WITH THE FIREPLACE MUST  BE LISTED.  SEE LIST IN THE INS

TALL

ATION 

INSTRUCTIONS.

• 

REPLACE GLASS WITH CERAMIC GLASS 5 mm  THICK.

• 

FOR SAFE OPER

ATION INS

TALL IN ACCORDANCE 

WITH THE MANU

FACTURER’S INSTRUCTIONS.

• 

CAUTION: COMBUSTION AIR OPENING MUST NOT  BE OBSTRUCTED.

• 

DO NOT OVERFIRE THE FIREPLACE.

• 

OPER

ATE THE FIREPLACE WITH DOOR FUL

LY OPEN 

OR FUL

LY CLOSED ON

LY

.

• 

POUR USAGE AVEC LE BOIS SEULEMENT

• 

UN 

TABLIER NON COMBUSTIBLE DOIT ÊTRE INS

TALLÉ À 

L’

AV

ANT DU FOYER . DIMENSION MINIMALE DE 18 po. (457 

mm) 

PAR 36 po. (914 mm) DE LARGE.

• 

CE FOYER N’EST 

PAS HOMOLOGUÉ POUR ÊTRE UTILISÉ 

AVEC UN ENSEMBLE DE BÛCHES À GAZ SANS CONDUIT  D’É

VACU

ATION. AFIN DE RÉDUIRE LES RISQUES D’INCENDIE 

OU DE BLESSURES, N’INS

TALLEZ 

PAS DE BÛCHES À GAZ SANS 

CONDUIT D’É

VACU

ATION À 

L’INTÉRIEUR DE CE FOYER.

• 

ALIMEN

TA

TION ÉLECTRIQUE: 120

V, 60 Hz

• 

UTILISER SEULEMENT 

AVEC UNE CHEMINÉE 6 po. (150 mm) DE 

DIAMÈTRE, MODÈLE ASHT+, S2100+, , OU AC  HOMOLOGUÉE.

• 

PEUT ÊTRE RACCORDÉ SUR UNE CHEMINÉE DE MAÇONNERIE  TEL QUE DÉCRIT DANS LE MANUEL D’INS

TALL

ATION.

• 

LES COMPOSANTES UTILISÉES 

AVEC LE FOYER DOIVENT 

ÊTRE HOMOLOGUÉES. VOIR LA LISTE DANS LE MANUEL  D’INS

TALL

ATION.

• 

REMPLACER LA VITRE 

AVEC UN VERRE CÉRAMIQUE DE 5mm 

D’É

PAISSEUR.

• 

POUR UNE UTILIS

ATION SÉCURI

TAIRE, INS

TALLER CONFORMÉ-

MENT AUX DIRECTIVES DU 

FABRICAN

T.

• 

ATTENTION : NE 

PAS OBSTRUER LES ARRIVÉES D’AIR COMBU-

RAN

T.

• 

NE 

PAS 

FAIRE SURCHAUFFER LE FOYER.

• 

LA PO

R

TE DU FOYER DOIT DEMEURER TO

TALEMENT OUVE

R

TE 

OU TO

TALEMENT FERMÉE LORSQUE LE FOYER FONCTIONNE.

• 

CON

TACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INS

TALL

ATION INSPECTIONS IN YOUR 

AREA.

• 

CON

TACTEZ LES RESPONSABLES DE VOTRE REGION A PROPOS DES RESTRICTIONS ET INSPECTIONS D’INS

TALL

ATION.

• 

SEE IHP INS

TALL

ATION AND OPER

ATING INSTRUCTIONS FOR THIS MODEL.

• 

INS

TALL AND USE ON

LY IN ACCORDANCE WITH THE MANU

FACTURER’S INSTRUCTIONS AND LOCAL BUILDING CODES.

• 

SPECIAL METHODS ARE REQUIRED WHEN 

PASSING THROUGH A 

W

ALL OR CEILING. SEE INSTRUCTIONS AND BUILDING 

CODES.

• 

PREVENT CREOSOTE FIRE: INSPECT CHIMNEY CONNECTOR AND CHIMNEY FLUE MONTH

LY AND CLEAN IF NECESSA

R

Y. 

• 

 DO NOT OVERFIRE. IF DOME OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING.

• 

KEEP FURNISHINGS AND OTHER COMBUSTIBLE M

ATERIALS A CONSIDERABLE DIS

TANCE 

AW

AY FROM APPLIANCE.

• 

MAINTENIR LES MEUBLES ET AUTRES OBJETS À UNE DIS

TANCE SÉCURI

TAIRE DU FOYER.

THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL.

CET APPAREIL DE CHAUFFAGE AU BOIS DOIT ÊTRE INSPECTE ET ENTRETENU PÉRIODIQUEMENT POUR FONCTIONNER  CORRECTEMENT. VOIR LE MANUEL DU PROPRIÉTAIRE POUR PLUS D’INFORMATION. L’UTILISATION DE CET APPAREIL DE CHAUFFAGE AU BOIS DE MANIÈRE INCOMPATIBLE AVEC LES INSTRUCTIONS DU MANUEL DU PROPRIÉTAIRE  CONSTITUE UNE INFRACTION AUX RÉGULATIONS FÉDÉRALES.

DO

 N

OT

 US

E A

 FI

REP

LA

CE

 INS

ER

OR

 O

THE

PROD

UCTS

 

N

O

SP

EC

IF

IE

D

 FOR

 U

SE

 W

ITH TH

IS 

PR

O

D

U

CT

 

NE

 PAS 

UT

ILIS

ER 

DE 

POÊ

LE E

NCA

ST

RAB

LE OU

 D

'AU

TR

ES 

PR

ODUITS

 

NO

N S

CI

FI

ÉS

 COM

M

ÉTA

NT

 UTIL

ISA

BLES

 A

VEC C

PRO

DU

IT

.

26

Содержание Superior Fireplaces WCT6820WS

Страница 1: ...uctions This installation manual will enable you to obtain a safe efficient and dependable installation of your fireplace system Please read and understand these instructions before beginning your installation Do not alter or modify the fireplace or its components under any cir cumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney comp...

Страница 2: ...ey lengths Elbows where necessary Associated components as per these installation instructions 6 diameter chimney Canada Models ASHT S2100 manufacture by Security Chimneys or DuraTech Canada DTC manufactured by DuraVent only including Chimney lengths Elbows where necessary Associated components as per these installation instructions instructions provided by the venting manufacturer Decorative Door...

Страница 3: ...r inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free operation nor are we respon sible for inadequate system draft caused by mechanical systems general construction conditions inadequate chimney heights adverse wind conditions and or unusual environmental factors or conditions ...

Страница 4: ... primary air and air boost controls fully openedduring10to20minutesafterreloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost can be closed and the primary air set to a medium setting You know you have reached the desired temperature when closing the primary air control you can see a flame at the top of the firebox The benefit...

Страница 5: ...ommended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fresh air immediately Somepeoplearemoreaffectedbycarbonmon oxide than others including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes It is against federal regulatio...

Страница 6: ... The use of a firewood moisture meter is rec ommended to ensure the firewood contains less than 20 moisture Seasoning Guide Softwoods 6 months to 18 months Hardwoods 12 months to 24 months Logsthatare5 diameteracrossorlargershould be split in half three pieces if over 8 inches and four pieces when over a foot across If a tree has been dead for 2 4 years it still needs to be cut split and seasoned ...

Страница 7: ...lace facade An Allen key 1 8 not supplied will be necessary for this adjustment Checking Door Seal A one inch strip of paper may be used to perform a test of the integrity of the door seal Close the door on the paper in at least eight points It is normal to feel only a slight amount of friction The door gasket does not need to be tight in all areas since a small amount of leakage is not hazardous ...

Страница 8: ...the entire width of the fireplace The combustible floor in front of the fireplace must be covered with a non combustible ma terial tile marble stone etc See Figure 9 COLD CLIMATE INSTALLATIONS Climates where temperatures will fall below 32 F 0 C The heating performance of the appliance will vary depending upon the level of insulation housedesign howtheapplianceisoperated etc If this fireplace is b...

Страница 9: ...box and glass are maintained at hot temperatures see RefuelingForBestPerformance Tocleanthe glass there are a number of specially designed cleaners YourauthorizedIHPdealercanrecom mend a suitable cleaner which is available in your area Regular household glass cleaners will not clean creosote Do not use abrasives such as steel pads steel wool or oven cleaner as they will scratch the glass DO NOT US...

Страница 10: ...installation instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without notice Allframingdimensionscalculatedfor 1 2 dry wall at the fireplace face If sheathing the chase or finishing with other thickness materials calcula tions will need to be made Thefireplacemustnotbeincontact with any insulation or loose filling material C...

Страница 11: ...lation In Outside Walls Of Chase Solid Continuous Surface Outside Base Insulation Thermal Barrier 8 Level 7 2 1 m Min 6 8 2 m Min 8 2 4 m Level 42 1067mm 2 x 3 Min 51mm x 76mm Rock Board or Other Noncombustible Facing Drywall NOTE It is recommended that the chase walls and floor be insulated in the same manner using the same insulation as the rest of the building below the attic SEE NOTE Mantel an...

Страница 12: ...e duct is twenty 20 feet 6 1 m See note below B The air intake register must not be installed more than ten 10 feet 3050 mm above the base of the fireplace C The fresh air must come from outside the house The air intake must not draw air from the attic basement or garage D The air intake should be installed where it is not likely to be blocked by snow or exposed to extreme wind and away from autom...

Страница 13: ...and no 2 Phillips screwdriver GENERAL INFORMATION If you encounter any problems need clarification of these instructions or are not qualified to properly install this kit contact you local distribu tor or dealer Readthisinstructionsheetinitsentiretybeforebeginningtheinstallation ALL WARNINGS AND PRECAUTIONS IN THE INSTALLATION AND OPERATION MANUAL PROVIDED WITH THE APPLIANCE APPLY TO THESE INSTRUC...

Страница 14: ...11 280mm Min Duct Ring Duct Adaptor Tab It is recommended that the ducted flex kit duct system be installed in the following order 1 Plan and frame fireplace and outlet locations prior to ducted flex kit installation 2 Remove the two 8 diameter cutouts on top of the fireplace Then cut the insulation in order to obtain two 8 diameter openings and remove the insulation 3 On the duct adaptor bend the...

Страница 15: ...he outlet grill The minimum height from thebottomoftheunittothecenteroftheoutletis68 1 7m with the minimum distance from the center of outlet to the ceiling and for the center of the outlet to a side wall of 11 279mm Do not connect the hot air ducts to a central heating system Use only IHP grills and components as described in this manual Ensure that the flex insulation and sheathing do not touch ...

Страница 16: ...achieved by having the chimney supported by the supports The maximum chimney length that can be supported by the fireplace is nine 9 feet 2 75 m 6 The chimney must extend at least three 3 feet 915 mm above its point of contact with the roof and at least two 2 feet 610 mm higher than any wall roof or building within ten 10 feet 3m of it 7 If the chimney extends higher than five 5 feet 1 500 mm abov...

Страница 17: ...ber of equal size to the joist should be used Figure 26 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 27 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney Flue Diameter 6 A 12 7 16 B 12 7 16 Table 3 If the area above the ceiling is an attic go to step 5 2 Install SNAP PAK chimney sections start ing at the top of the appliance Leave the first section loose until the installat...

Страница 18: ...rance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessary to secure them to the outside wall with bands SPWB at eight foot intervals and 2 from combustibles Wall Bands SPWB are secured to the chimney by placing band around the chimney and tightening clam...

Страница 19: ...tall the next SP chimney section through the roof See Figure 32 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk around the pipe at the top edge of the flash ing Wrap the storm collar around the pipe and imbed the edge in the caulk to prevent leakage around the pipe 4 Continue to install pipe sections until the pr...

Страница 20: ...dverse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support for your application using either a roof brace Figure 36 or a support band with guy wires Figure 37 Figure 34 IF 10 FEET OR LESS L944 FIG21 THEN BUT MUST BE AT LEAST 2 FEET NEVER LESS THAN 3 FEET Fig...

Страница 21: ...ed with a chimney adaptor suitable for use with IHP SnapPak venting In Canada the use of Security Chimneys ASHT adaptor is required Security part number 6IHP1 or 6IHP2 One inch wall Two inch wall Figure 38 Chimney Adaptor Canada only 18 460 mm 16 410 mm 18 460 mm 18 460 mm 16 410 mm CANADA ONLY CHIMNEY INSTALLATION INSTRUCTIONS USING SECURITY CHIMNEYS ASHT CANADA APPROVED VENTING SYSTEMS 6 diamete...

Страница 22: ... chimney at 30º 3 Increase the size of the hole until a 30º liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip through the hole a 30º liner elbow and connect it to the liner 6 Add a small liner section to the other end of the liner elbow which will allow the liner to extend at least 12 measured at the top of th...

Страница 23: ...ng UZI UZI EPA Fireplace HeatFlo Convection Kit EPA Heatflo Conv Kit EPA HEATFLO KIT F3790 OPTIONAL INSTALLATION ACCESSORIES Fireplace Kits Description Cat Part No Central Forced Air Kit Accessories Central Forced Air Kit Central forced air kit including blower BISZY flex adaptor BISAF 2 clamps variable speed control VRUW thermo disk VTU fan to flexible pipe adaptor BISAVF back draft damper BISBD ...

Страница 24: ...Log Retainer Bar PR SR2323 Gasket Kit Glass 69 1 x 5 16 steel and cast doors PR SR1823H Gasket Kit Steel Door Frame 73 5 8 dia PR SR1685D Gasket Kit Cast Door Frame 73 5 8 dia PR SR1823G Touch up Paint Aerosol Black Metallic SBMB6309 H8159 Touch up Paint Charcoal for hammered steel facade PR P6201 Coupler Outside Air connects UZI to fireplace UZIAD Coupler for AC Chimney connects ACZI to fireplace...

Страница 25: ... and Misc Chimney Components 8 length 6 Dia 6DTC 08SS 12 length 6 Dia 6DTC 12SS 18 length 6 Dia 6DTC 18SS 24 length 6 Dia 6DTC 24SS 36 length 6 Dia 6DTC 36SS 48 length 6 Dia 6DTC 48SS Adjustable Length 12 6 Dia 6DTC 12TASS 15º elbow 6 Dia 6DTC E15SS 30º elbow 6 Dia 6DTC E30SS Rain Termination Cap 6 Dia 6DTC VC Spark Arrester Screen universal spark arrester band DTC SA Wall Band DTC WSU Supports Of...

Страница 26: ...RATE THE FIREPLACE WITH DOOR FULLY OPEN OR FULLY CLOSED ONLY POUR USAGE AVEC LE BOIS SEULEMENT UN TABLIER NON COMBUSTIBLE DOIT ÊTRE INSTALLÉ À L AVANT DU FOYER DIMENSION MINIMALE DE 18 po 457 mm PAR 36 po 914 mm DE LARGE CE FOYER N EST PAS HOMOLOGUÉ POUR ÊTRE UTILISÉ AVEC UN ENSEMBLE DE BÛCHES À GAZ SANS CONDUIT D ÉVACUATION AFIN DE RÉDUIRE LES RISQUES D INCENDIE OU DE BLESSURES N INSTALLEZ PAS DE...

Страница 27: ...al use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause i...

Страница 28: ...or any questions or concerns REPLACEMENT PARTS See Page 19 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number...

Отзывы: