SAFETY / LISTING LABEL - WCT6820WS
IHP 15-22848
CLEARANCES TO COMBUSTIBLES:
SIDE
W
ALL (FROM DOOR EDGE)
24 in. (610 mm)
MANTEL (ABOVE FIREPLACE’S BASE)
42 in. (1067 mm)
BACK
W
ALL (FROM S
PACERS)
0 in.
(0 mm)
ABOVE THE FIREPLACE (FROM
THE BASE OF THE FIREPLACE)
6 ft. 8 in. (2032 mm)
)
m
m
15(
.
ni
2
Y
EN
MI
HC
DÉGAGEMENTS AUX COMBUSTIBLES:
MUR L
ATÉRAL (DE
L’OUVE
RTURE DE LA PO
RTE)
24 po.
(610 mm)
LINTEAU (AU-DESSUS DE LA BASE DU FOYER)
42 po.
(1067 mm)
MUR ARRIÈRE ET CÔTÉ DU FOYER (DES ES
PACEURS)
0 po.
(0 mm)
AU-DESSUS DU FOYER (À
PA
RTIR DE LA BASE
)
m
m
23
02(
.
op
8 .i
p
6
)
RE
YO
F
UD
)
m
m
15(
.
op
2
E
ÉNI
ME
HC
LISTED
FACTO
RY BUI
LT FIREPLACE
FOYER PRÉ
FABRIQUE HOMOLOGUÉ
P/N 900433-00, REV. 0, 05/2015
IGN 15-22848
DA
TE OF MFG.
1
2
3
4
5
6
7
8
9
10
11
12
2019-20-21-22-23-24-25
INS
TALL WITH MINIMUM CLEARANCES TO
W
ALL
AS SHOWN IN INCHES.
SIDE
W
ALL - BACK
W
ALL
INS
TALL
ATION
0”
0”
FIREPLACE
FRONT
CORNER INS
TALL
ATION
0”
0”
FIREPLACE
FRONT
FLOOR PROTECTOR MINIMUM DIS
TANCE
FROM OPENING IN INCHES
HEA
RTH EXTENSION M
ATERIAL :
-
3/8 “ THICKNESS NON COMBUSTIBLE
M
ATERIAL
-
OR EQUI
VALENT
FIREPLACE
FRONT
18”
36”
FIREPLACE, ALSO FOR USE IN MANU
FACTURED
HOMES WITH SOLID FUEL ON
LY
CE FOYER EST ÉGALEMENT CE
RTIFIÉ POUR
INS
TALL
ATION DANS LES MAISONS MOBILES.
COMBUSTIBLES SOLIDES SEULEMEN
T.
Conforms to / Conforme au : UL STD 127
Certified to / Certifié au : ULC STD S610
Serial No. Numéro
de
séri
e
Model / Modèle:
WCT6820WS
Report No. / Rapport nº
14-199
C
US
Manufactured by / Fabriqué par: INNOVATIVE HEARTH PRODUCTS
1502 14th St. NW
Auburn,
W
A 98001 USA
Certification test emission value 3.7 g/hr per 2015 standard Valeur d’émission du test d’homologation 3,7 g/h selon la norme 2015
U.S. ENVIRONMEN
TA
L PROTECTION
AGENCY
Certified to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020.
•
USE WOOD FUEL ON
LY
•
NON COMBUSTIBLE HEA
R
TH EXTENSION MUST BE
INS
TALLED
AT FRONT OF UNIT EXTENDING 18 in.
(457 mm)
AT FRONT AND 36 in. (914 mm) WIDE
MINIMUM .
•
THIS FIREPLACE HAS NOT BEEN TESTED WITH UNVENTED GAS LOG SE
T. TO REDUCE RISK OF
FIRE OR INJU
R
Y DO NOT INS
TALL AN UNVENTED
GAS LOG SET INTO THE FIREPLACE.
•
ELECTRICAL R
ATING: 120
V, 60 Hz
•
CHIMNEY TYPE: USE ON
LY WITH LISTED 6 in.
DIAMETER CHIMNE
Y, CE
R
TIFIED MODEL ASHT+,
S-2100+, , OR AC.
•
CAN BE CONNECTED TO A MASON
R
Y CHIMNEY AS
DESCRIBED IN THE INS
TALL
ATION INSTRUCTIONS.
•
COMPONENTS USED WITH THE FIREPLACE MUST BE LISTED. SEE LIST IN THE INS
TALL
ATION
INSTRUCTIONS.
•
REPLACE GLASS WITH CERAMIC GLASS 5 mm THICK.
•
FOR SAFE OPER
ATION INS
TALL IN ACCORDANCE
WITH THE MANU
FACTURER’S INSTRUCTIONS.
•
CAUTION: COMBUSTION AIR OPENING MUST NOT BE OBSTRUCTED.
•
DO NOT OVERFIRE THE FIREPLACE.
•
OPER
ATE THE FIREPLACE WITH DOOR FUL
LY OPEN
OR FUL
LY CLOSED ON
LY
.
•
POUR USAGE AVEC LE BOIS SEULEMENT
•
UN
TABLIER NON COMBUSTIBLE DOIT ÊTRE INS
TALLÉ À
L’
AV
ANT DU FOYER . DIMENSION MINIMALE DE 18 po. (457
mm)
PAR 36 po. (914 mm) DE LARGE.
•
CE FOYER N’EST
PAS HOMOLOGUÉ POUR ÊTRE UTILISÉ
AVEC UN ENSEMBLE DE BÛCHES À GAZ SANS CONDUIT D’É
VACU
ATION. AFIN DE RÉDUIRE LES RISQUES D’INCENDIE
OU DE BLESSURES, N’INS
TALLEZ
PAS DE BÛCHES À GAZ SANS
CONDUIT D’É
VACU
ATION À
L’INTÉRIEUR DE CE FOYER.
•
ALIMEN
TA
TION ÉLECTRIQUE: 120
V, 60 Hz
•
UTILISER SEULEMENT
AVEC UNE CHEMINÉE 6 po. (150 mm) DE
DIAMÈTRE, MODÈLE ASHT+, S2100+, , OU AC HOMOLOGUÉE.
•
PEUT ÊTRE RACCORDÉ SUR UNE CHEMINÉE DE MAÇONNERIE TEL QUE DÉCRIT DANS LE MANUEL D’INS
TALL
ATION.
•
LES COMPOSANTES UTILISÉES
AVEC LE FOYER DOIVENT
ÊTRE HOMOLOGUÉES. VOIR LA LISTE DANS LE MANUEL D’INS
TALL
ATION.
•
REMPLACER LA VITRE
AVEC UN VERRE CÉRAMIQUE DE 5mm
D’É
PAISSEUR.
•
POUR UNE UTILIS
ATION SÉCURI
TAIRE, INS
TALLER CONFORMÉ-
MENT AUX DIRECTIVES DU
FABRICAN
T.
•
ATTENTION : NE
PAS OBSTRUER LES ARRIVÉES D’AIR COMBU-
RAN
T.
•
NE
PAS
FAIRE SURCHAUFFER LE FOYER.
•
LA PO
R
TE DU FOYER DOIT DEMEURER TO
TALEMENT OUVE
R
TE
OU TO
TALEMENT FERMÉE LORSQUE LE FOYER FONCTIONNE.
•
CON
TACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INS
TALL
ATION INSPECTIONS IN YOUR
AREA.
•
CON
TACTEZ LES RESPONSABLES DE VOTRE REGION A PROPOS DES RESTRICTIONS ET INSPECTIONS D’INS
TALL
ATION.
•
SEE IHP INS
TALL
ATION AND OPER
ATING INSTRUCTIONS FOR THIS MODEL.
•
INS
TALL AND USE ON
LY IN ACCORDANCE WITH THE MANU
FACTURER’S INSTRUCTIONS AND LOCAL BUILDING CODES.
•
SPECIAL METHODS ARE REQUIRED WHEN
PASSING THROUGH A
W
ALL OR CEILING. SEE INSTRUCTIONS AND BUILDING
CODES.
•
PREVENT CREOSOTE FIRE: INSPECT CHIMNEY CONNECTOR AND CHIMNEY FLUE MONTH
LY AND CLEAN IF NECESSA
R
Y.
•
DO NOT OVERFIRE. IF DOME OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING.
•
KEEP FURNISHINGS AND OTHER COMBUSTIBLE M
ATERIALS A CONSIDERABLE DIS
TANCE
AW
AY FROM APPLIANCE.
•
MAINTENIR LES MEUBLES ET AUTRES OBJETS À UNE DIS
TANCE SÉCURI
TAIRE DU FOYER.
•
THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. CONSULT THE OWNER’S MANUAL FOR FURTHER INFORMATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL.
•
CET APPAREIL DE CHAUFFAGE AU BOIS DOIT ÊTRE INSPECTE ET ENTRETENU PÉRIODIQUEMENT POUR FONCTIONNER CORRECTEMENT. VOIR LE MANUEL DU PROPRIÉTAIRE POUR PLUS D’INFORMATION. L’UTILISATION DE CET APPAREIL DE CHAUFFAGE AU BOIS DE MANIÈRE INCOMPATIBLE AVEC LES INSTRUCTIONS DU MANUEL DU PROPRIÉTAIRE CONSTITUE UNE INFRACTION AUX RÉGULATIONS FÉDÉRALES.
•
DO
N
OT
US
E A
FI
REP
LA
CE
INS
ER
T
OR
O
THE
R
PROD
UCTS
N
O
T
SP
EC
IF
IE
D
FOR
U
SE
W
ITH TH
IS
PR
O
D
U
CT
•
NE
PAS
UT
ILIS
ER
DE
POÊ
LE E
NCA
ST
RAB
LE OU
D
'AU
TR
ES
PR
ODUITS
NO
N S
PÉ
CI
FI
ÉS
COM
M
E
ÉTA
NT
UTIL
ISA
BLES
A
VEC C
E
PRO
DU
IT
.
26