AIR  FOR COMBUSTION  AND VENTILATION  

continued

 

 

The space in the example is a confined  space because the actual Btu/ 
Hr used is more  than the maximum  Btu/Hr  the space can support. 
You must  provide additional fresh air. Your options  are as follows: 
A.  Rework worksheet,  adding the space of an adjoining  room.  If the

 

extra space provides an unconfined space, remove door to adjoining

 

room or add ventilation  grills  between rooms.  See Ventilation  Air

 

From Inside Building.

 

B.  Vent  room directly  to the outdoors.  See Ventilation  Air From

 

Outdoors.

 

C.  Install  a lower  Btu/Hr  fireplace,  if lower  Btu/Hr  size makes room 

unconfined.

 

If the actual Btu/Hr  used is less than the maximum  Btu/Hr  the space 
can support,  the space is an unconfined  space. You will need no ad- 
ditional fresh air ventilation.

 

 

WARNING: If the area in which the heater may be 

operated does not meet the required volume for indoor

 

 

Ventilation  Air From Outdoors

 

Provide extra fresh air by using ventilation grills  or ducts. You must 
provide two permanent openings:  one within  12" of the ceiling  and 

one within  12" of the floor. Connect  these  items directly  to the out

doors or spaces open to the outdoors.  These spaces include  attics 
and crawl  spaces.  Follow  the  National  Fuel Gas Code, ANSI Z223.1/ 
NFPA  54, Air for Combustion  and  Ventilation  for required  size  of 
ventilation grills or ducts.

 

 

IMPORTANT: Do not provide openings for inlet  or outlet air 
into attic if attic  has a thermostat-controlled  power vent. 
Heated air entering the attic will  activate the power vent.

 

 

 
 
 

 
 

Ventilated 

combustion air, combustion and ventilation  air shall

 

be  provided  by one  of  the  methods  described  in the 
National  Fuel  Gas Code,  ANSI Z223.1/NFPA  54, the 
International Fuel Gas Code, or applicable local codes.

 

 

 
 

Outlet 
Air 

Outlet 
Air 

Attic 

 
 
 

 

To Attic 

 

VENTILATION AIR

 

Ventilation  Air From Inside Building

 

This fresh air would  come from  an adjoining  unconfined  space. When 
ventilating to an adjoining  unconfined  space, you  must  provide  two 
permanent openings: one within  12" of the ceiling and one within  12" 

of the floor on the wall connecting the two spaces (see options 1 and 

 

2, Figure 4). You can also remove door into adjoining  room  (see option

 

3, Figure 4 ). Follow  the National Fuel Gas Code, ANSI Z223.1/NFPA

 

 

 
 
 

Inlet 
Air 

 

 
 
 

 
 

Inlet Air  

Ventilated 

Crawl Space 

 

To 

Crawl 

Space 

54, Air for Combustion  and Ventilation  for required  size of ventilation 
grills or ducts.

 

Figure 5 - Ventilation  Air from Outdoors

 

 

 
 

12" 

 

 

Ventilation 

Grills Into 

Adjoining 

Room, 

Option 1 

 

 

Or 

Remove 

Door into 
Adjoining 

Room, 
Option 

 

Ventilation Grills Into 

Adjoining Room, 

Option 2 

 

 

12" 

 
 
 

 
 

 

Figure 4 - Ventilation Air from Inside Building

 

Содержание Superior Fireplaces VRE4536RH

Страница 1: ......

Страница 2: ...allation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING FOR USE ONLY WITH A LISTED GAS FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40 000 BTU H DO NOT BUILD A WOOD FIRE WARNING If the information in this manual is not followed exactly a fire or explosion may result caus ing property damage persona...

Страница 3: ...ely before trying to assemble operate or service this fireplace Improper use of this fireplace can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning DANGER Carbon monoxide poisoning may lead to death WARNING Any change to this firebox or its controls can be dangerous WARNING Do not allow fans to blow directly into the firebox Avoid any drafts th...

Страница 4: ...proved ANSI Z21 11 2 deco rative type unvented room heaters Physical size limitations apply Refer to minimum firebox requirements supplied with log heater It requires no outside venting or chimney making installation easy and inexpensive State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natur...

Страница 5: ... 01B 36 MODELS PRODUCT SPECIFICATIONS 29 22 1 2 30 1 2 19 20 1 4 Ref 3 3 4 4 7 8 35 1 4 36 HEARTH 1 1 4 11 1 8 54 1 2 30 50 365 16 7 7 7 8 36 45 1 8 97 16 35 16 7 3 8 111 8 Figure 1 36 Models VRE6036RS VRE6036IS VRE6036RH and VRE6036IH ...

Страница 6: ... MODELS PRODUCT SPECIFICATIONS continued 30 5 16 26 3 8 32 3 8 21 3 4 23 Ref 4 7 8 41 3 8 1 1 4 3 3 4 42 HEARTH 11 1 8 54 1 2 30 50 36 5 16 7 7 8 7 42 51 1 8 9 7 16 3 5 16 8 3 4 13 Figure 2 42 Models VRE6042RS VRE6042IS VRE6042RH and VRE6042IH ...

Страница 7: ...0 MODELS PRODUCT SPECIFICATIONS continued 38 5 16 34 3 8 32 3 8 21 3 4 23 Ref 3 3 4 4 7 8 49 3 8 50 HEARTH 1 1 4 11 1 8 54 1 2 30 50 365 16 7 7 8 7 50 59 1 8 97 16 35 16 8 3 4 13 Figure 3 50 Models VRE6050RS VRE6050IS VRE6050RH and VRE6050IH ...

Страница 8: ... FOR FIREBOX LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or uncon fined space Space Includes the room in which you will install heater plus any ad joining rooms with doorless passageways or ventilation grills between the rooms 1 Determine the volume of the space length x width x height Length x Width x Height cu ft volume ...

Страница 9: ...nd crawl spaces Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Ventilated combustion air combustion and ventilation air shall be prov...

Страница 10: ...on the rear sides top or bottom of your firebox except where standoff spacers are integrally attached If standoff spacers are attached to your firebox these spacers can be placed directly against wall or framing materials Use the dimensions shown for rough opening to create the easiest installation Use dimensions shown for rough openings to create the easiest installation see Built In Firebox Inst...

Страница 11: ...peratures meet the requirement of the national product standard Fol low all minimum clearances shown in this manual Wall board or facing material above combustible material including decorative mantel ornaments or other similar projec tions off of the facing material Framing 12 6 3 4 1 1 2 Mantel Shelf mantel shelf must NOT extend beyond this profile 45 3 8 36 Models 54 5 8 30 1 8 Material Firebox...

Страница 12: ...ocation Make sure mantel will be flush against wall when installed 4 Carefully slide cabinet mantel over firebox Be careful not to scratch firebox cabinet mantel flooring etc when installing see Figure 12 5 Install and properly test gas log heater Follow installation in structions included with the vent free gas log heater that is being installed Nails or Wood Screws Cabinet Mantel Gas Line Access...

Страница 13: ...lling the rear panel Make sure panel is center before continuing 4 Install the right and left refractory panels with the gas line knock outs orientated down toward the bottom refractory Align the left and right panels with the rear panel so the grout lines line up 5 Install the upper corner brackets and tighten set screws Figure 13 INSTALLING FIREPLACE HOOD AND SCREENS 1 Attach hood to firebox usi...

Страница 14: ...through the rear at gas line conduit sleeve if using a raised platform add height Provide sufficient gas line into fireplace chamber for fitting connection see Figure 17 Note Secureincoming gas line to wood framing to provide rigidity for threaded end Fireplace Gas Line Conduit Insulation Gas Conduit Cover Remove Knockout Side Firebrick Finished Side 1 2 Dowel Brick with Access Hole 4 Repack insul...

Страница 15: ...14 Superiorfireplaces US com 127029 01B PARTS 36 42 AND 50 SUPERIOR MODELS 9 8 11 10 7 12 6 15 16 5 14 13 19 4 11 22 1 3 11 20 21 20 18 2 12 13 14 17 15 16 14 ...

Страница 16: ...lace Top 50 1 9 23490SA Standoff 4 10 Fireplace Surround Assembly 1 11 109720 02 Clearance Spacer 6 12 117891 01 Fireplace Handle Bracket 4 13 20042 Outside Air Cover Plate 2 14 21171 Gas Conduit Cover 4 15 109752 01 Conduit One 2 16 109752 02 Conduit Two 2 17 Heat Shield Support 1 18 123298 02 Ash Box Assembly 1 19 Firebox Top 1 20 109457 03 Screen 36 2 109457 02 Screen 42 2 109457 01 Screen 50 2...

Страница 17: ...S 36 42 AND 50 SUPERIOR MODELS Picture may vary from actual WARNING Contact an IHP dealer to obtain any of these parts Never use substitute materials not approved by IHP Use of non approved parts can result in poor performance and safety hazards ...

Страница 18: ...Red Ash Panel 42 Red Ash Panel 50 Red 1 1 1 6 110822 01 Corner Refractory Bracket 2 KEY VRE4536WS VRE4536WH VRE4542WS VRE4542WH VRE4550WS VRE4550WH NO PART NO DESCRIPTION F0474 F0476 F0478 F0480 F0482 F0484 QTY 1 116084 01 111426 01 111428 01 Hearth 36 Natural White Hearth 42 Natural White Hearth 50 Natural White 1 1 1 2 116082 01 116087 01 125832 01 125835 01 125838 01 125841 01 Right Stacked 36 ...

Страница 19: ...please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty When calling or writing please have your model and serial numbers of your fireplace ready Model and serial number information are in the firepla...

Страница 20: ...e excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from faulty installation or application of the Product IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems me...

Страница 21: ...ion Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information P127029 01 Printed in U S A 2014 IHP LLC P N 127029 01 Rev B 01 2015 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 IHP US com ...

Отзывы: