Operation
900004-00Q, 10/2018
Innovative Hearth Products
DRT2000 and DRC2000 Direct-Vent Fireplaces
50
Figure 42 - Control compartment
Figure 43 - Magnetic latch & barrier support bracket
Gas Controls
The standard controls for fireplace operation are located in the control compartment, below the glass door
(Figure
34)
. Optional control switches are also available.
Millivolt and electronic gas control systems operate differently. Before lighting and operating the fireplace determine
if it is a millivolt or electronic system:
• Millivolt Fireplaces
(Figure 1)
• Electronic Fireplaces
(Figure 2)
Familiarize yourself with the gas control valve and the lighting procedure
(Pages 64-67)
.
Millivolt Fireplaces
Detailed lighting instructions are found on
Pages 64-67
. Also, millivolt fireplace lighting instructions are found on
the pull-out lighting instructions attached to the gas control valve.
When the pilot is lit, the main burner can be turned ON/OFF using a wall switch, remote control, optional on-unit
rocker switch (FRS), or wall thermostat.
If the millivolt fireplace is equipped with an optional remote switch (wall switch, remote control, rocker switch, or
wall thermostat) and the pilot is lit, the fireplace main burner can be turned ON/OFF using the optional switch.
Burn-in Period
The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the
lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few
days.
NOTE: Ventilate the site during the burn-in period. The resulting odor and haze may set off a smoke detector. Do not
operate the blower during the burn-in period.
A white film may develop on the glass front during the first few fires as part of the burn-in period. The glass
should be kept clean during the burn-in period to prevent the film from baking on—making it very difficult to
remove
(Cleaning the glass door on Page 57)
.
Accessing the Control Compartment
Removing the Control Compartment Door
1. Open the lower access panel by pulling at the top of the door.
2. Pull the hinge pin towards the middle of the fireplace to release the access panel and lift it up and away from the
fireplace
(Figure 42)
.
3. Store the panel in a secure location until reinstallation.
Magnetic
Latch
Barrier
Support
Bracket
Hinge Pin
(Pull to
Release)
Magnetic
Latch
Barrier
Support
Bracket