background image

SETTING THE COUNTDOWN TIMER

This remote control system can operate with a built-in countdown timer when the transmitter is in the ON or THERMO 

modes only (THERMO or ON must be displayed on the screen).

1.   Press and release the TIMER/TIME button on the 

       transmitter.  The word TIMER will appear and 0:15

       minutes will begin blinking on the screen (Fig. 21). 

2.  Press the UP or DOWN button on the transmitter to begin

     advancing through each of the countdown time options.  

     Available countdown times are 15 minutes, 30 minutes, 

    45 minutes, 1 hour, 1 hour 30 minutes, 2 hours, 

    2 hours 30 minutes, and each additional half-hour up to 

    nine (9) maximum hours.

3.  To set the TIMER press the SET button on the transmitter 

     if the system is 

ON

. It will remain ON until the time has 

expired.  If the system is in the THERMO mode, it will cycle on

     and off, as the room temperature requires until the “time” has expired.  

OPERATIONAL NOTE:

 When the timer is used in the THERMO mode, the THERMO operation will resume when the 

“time” has expired.  

LOW BATTERY INDICATOR 

A low battery icon will be visible in the upper left corner of the LCD screen when 

battery power has dropped significantly (Fig. 22).  At this time, approximately two weeks of 

battery power remains until the transmitter may experience partial or complete loss of 

functions. 

ROOM

SET

Fig. 22 Low Battery Sign

CHILDPROOF “LOCK-OUT” – (CP)

This remote control includes a CHILDPROOF “LOCK-OUT” feature that allows the user to “LOCK-OUT” operation of the 

appliance, from the TRANSMITTER.

SETTING “LOCK-OUT” – (CP)

1.  To activate the “LOCK-OUT” feature, 

press and hold

 the

     UP  and TIMER/TIME buttons, together, for 5 seconds.  

    The letters 

CP 

will appear in the TEMP frame on the LCD

    screen (Fig. 23).

2.  To disengage the “LOCK-OUT”, press and hold the UP

     and TIMER buttons, together for 5 seconds or more, and 

    the letters 

CP

 will disappear from the LCD screen and the 

    transmitter will return to its normal operating condition.

NOTE:

  If the appliance is already operating in the ON or THERMO MODES, engaging the “LOCK-OUT” will not cancel 

the operating MODE.  Engaging the “LOCK-OUT” prevents only the manual operation of the TRANSMITTER.  If in the 

auto modes, the THERMO operation will continue to operate normally.  To totally “LOCK-OUT” the operation of the 

TRANSMITTER’S operating signals; the transmitter’s MODE must be set to 

OFF

.

ROOM

SET

Fig. 23 Child Protection (

CP

)

IPH: RCL-S-STAT

REV. 3-19-14  Page 9

ROOM

SET

Fig. 21 Setting Timer

TIMER

TIME

UP

MODE

DOWN

SE

T

TIMER

TIME

UP

MODE

DOWN

SE

T

P/N 900257-00 Rev. A

Содержание RCL-S-STAT

Страница 1: ...s of the batteries as indicated on the casing When the batteries are inserted the screen in figure 2 with similar numbers will display Note If a LOW battery icon appears on the screen check the positi...

Страница 2: ...OWN buttons to program a new setting If no change is made to flashing digits within 15 seconds the system will complete the procedure last programmed and reset the display to its normal state SETTING...

Страница 3: ...tter With the slide switch in the OFF position away from the LEARN button the system is OFF It is suggested that the slide switch be placed in the OFF position if you will be away from your home for a...

Страница 4: ...f the receiver or remove the black wires and install wires directly to the receiver Be sure no splices measure longer than 20 feet and allow ample wire to remove the receiver for annual battery replac...

Страница 5: ...ONIC SPARK IGNITIONS The remote control receiver can be connected in series to a 24VAC transformer to the TR transformer terminal on the ELECTRONIC MODULE Connect the hot wire from the 24VAC transform...

Страница 6: ...E button on the transmitter to change the system to ON The spark electrode should begin sparking to ignite the pilot After the pilot is lit the main gas valve should open and the main gas flame should...

Страница 7: ...TING MODES the transmitter sends an RF signal every fifteen 15 minutes to the receiver indicating that the transmitter is within the normal operating range of 20 feet Should the receiver NOT receive a...

Страница 8: ...variation of 2 F 1 C between SET temperature and ROOM temperature which determines when the fireplace will be activated The SWING number values are 1 1 F 5 C 2 2 F 1 C and 3 3 F 1 6 C SETTING THE TEMP...

Страница 9: ...y Fig 22 At this time approximately two weeks of battery power remains until the transmitter may experience partial or complete loss of functions ROOM SET Fig 22 Low Battery Sign CHILDPROOF LOCK OUT C...

Страница 10: ...eceiver beeps when the MODE button is depressed on the transmitter they are communicating Note The receiver only beeps in ON OFF modes No beeping occurs from ON to Thermo mode If the receiver does not...

Отзывы: