IPH: RCL-S-STAT
REV. 3-19-14 Page 3
The factory setting for temperature is ºF. To change this setting to ºC, first press
and hold the UP and DOWN buttons on the transmitter at the same time. Follow
this same procedure to change from ºC back to ºF. When changing between the ºF
and ºC scales, the temperature in the SET frame defaults to the lowest temperature
(45º F, or 6º C). The highest SET temperature is 99º Fahrenheit (32º Celsius).
SETTING ºF / ºC SCALE
Fig. 10 Temperature Scale
The remote receiver operates on (4) AA-size 1.5V batteries.
It is recommended that
ALKALINE
batteries be used for
longer battery life and maximum microprocessor
performance. IMPORTANT: New or fully charged batteries
are essential for proper operation of the remote receiver.
The remote receiver houses the microprocessor that
responds to commands from the transmitter to control
system operation. It emits one beep when it receives an
ON or OFF command manually, but no beep when cycling
on and off automatically in THERMO mode. The remote
receiver has a 3-position slide switch for selecting the ON/
REMOTE/OFF mode of operation:
•
With the slide switch in the
ON position (toward the LEARN button), the system will remain
ON
until the slide
switch is placed in the
OFF
or
REMOTE
position.
•
With the slide switch in the
REMOTE position (centered), the system will only operate if the remote receiver
receives commands from the transmitter.
•
With the slide switch in the
OFF position (away from the LEARN button), the system is
OFF
.
•
It is suggested that the slide switch be placed in the
OFF
position if you will be away from your home for an
extended period of time. If the remote receiver is mounted out of children’s reach, placing the slide switch in the
OFF
position also functions as a safety “lock-out” by both turning the system off and rendering the remote receiver
inoperative.
REMOTE RECEIVER
REMOTE
ON
OFF
LEARN
Requires 4-AA 1.5V
alkaline batteries
Learning
button
Remote Receiver
Batt
ery c
over
slide
s on
/off
Slide
Switch
ON
REMOTE
OFF
Fig. 11 Remote Receiver
INSTALLATION PRECAUTIONS
This remote control system must be installed exactly as outlined in these instructions. Read all instructions completely
before attempting installation. Follow instructions carefully during installation. Any modifications of the remote control
or any of its components will void the warranty and could cause a fire hazard.
Do not connect any gas valve or electronic module directly to 110-120VAC power. Consult gas appliance
manufacturer’s instructions and wiring schematics for proper placement of all wires. All electronic modules are to be
wired to manufacturer’s specifications.
The following wiring diagrams are for illustration purpose only. Follow instructions from manufacturer of gas valve and/
or electronic module for correct wiring procedures. Improper installation of electric components can cause damage to
electronic module, gas valve and remote receiver.
WARNING
TIMER
TIME
UP
MODE
DOWN
SE
T
P/N 900257-00 Rev. A