background image

3

SERIES

(C)(GC)IR18NTA/NMA

(C)(GC)IR30NTA/NMA

 MAX BTU

18,000

30,000

 Fuel Type

Natural Gas

Natural Gas

 Ignition

Electronic Push Button

Electronic Push Button

 Manifold Pressure

5 in. W.C.

5 in. W.C.

 Inlet Gas Pressure 

 Maximum

14 in. W.C.

14 in. W.C.

*Minimum (*For purposes of input adjustment)

6 in. W.C.

6 in. W.C.

 Dimensions (in.)
 ( H x W x D) (Height includes legs)

24.0 in. x 20.9 in. x 10.0 in. 

24.0 in. x 20.9 in. x 10.0 in.

 Weight (lbs.)

23.7

30

Fan Ratings (Select Models)

120V/60Hz,18W, 0.15A

120V/60Hz,18W, 0.15A

SERIES

(C)(GC)IR6NMA

(C)(GC)IR10NTA/NMA

 MAX BTU

6,000

12,000

 Fuel Type

Natural Gas

Natural Gas

 Ignition

Electronic Push Button

Electronic Push Button

 Manifold Pressure

5 in. W.C.

5 in. W.C.

 Inlet Gas Pressure 

 Maximum

14 in. W.C.

14 in. W.C.

*Minimum (*For purposes of input adjustment)

6 in. W.C.

6 in. W.C.

 Dimensions (in.)
 ( H x W x D) (Height includes legs)

19.8 in. x 17.0 in. x 8.9 in. 

19.8 in. x 17.0 in. x 8.9 in. 

 Weight (lbs.)

15.7

19.5

Fan Ratings (Select Models)

Not Available

120V/60Hz,18W, 0.15A

IMPORTANT SAFETY INFORMATION 

 

 

IMPORTANT:

 Read this owner’s manual carefully and completely before trying to assemble, operate, 

or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, 
explosion, electrical shock, and carbon monoxide poisoning.

Содержание (C)(GC)IR6PMA series

Страница 1: ...ch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier c...

Страница 2: ......

Страница 3: ...Electronic Push Button Manifold Pressure 10 in W C 10 in W C Inlet Gas Pressure Maximum 14 in W C 14 in W C Minimum For purposes of input adjustment 11 in W C 11 in W C Dimensions in H x W x D Height...

Страница 4: ...MA MAX BTU 6 000 12 000 Fuel Type Natural Gas Natural Gas Ignition Electronic Push Button Electronic Push Button Manifold Pressure 5 in W C 5 in W C Inlet Gas Pressure Maximum 14 in W C 14 in W C Mini...

Страница 5: ...temperatures locate this appliance out of traffic and away from furniture and draperies This appliance is intended for supplemental heating CARBON MONOXIDE POISONING Early signs of carbon monoxide po...

Страница 6: ...r shuts off do not relight until you have provided fresh outside air If heater keeps shutting off have it serviced 6 Do not run heater Where flammable liquids or vapors are used or stored Under dusty...

Страница 7: ...n must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a cop...

Страница 8: ...ry 1 000 BTUs 3 Kw of gas input per hour An unvented room heater is intended as a supplemental heater rather than a primary heat source In most supplemental heat applications the water vapor does not...

Страница 9: ...unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are...

Страница 10: ...TU hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct...

Страница 11: ...fresh air by using ventilation grills or duct You must provide two permanent openings one within 12 in of the ceiling and one within 12 in of the floor Connect these items directly to the outdoors or...

Страница 12: ...stalling heater next to vinyl or cloth wall coverings or operating heater where impurities such as tobacco smoke candles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to d...

Страница 13: ...d heater must be disconnected from gas supply and removed from wall before installing fan accessory Contact a qualified service person to do this 2 Remove fan access panel by removing 4 panel screws u...

Страница 14: ...f heater extending outside the table edge 2 Fasten Legs to heater using Support Leg Screws Fig 13 Note If the heater is to be installed directly on carpet ing tile or other combustible material other...

Страница 15: ...crew Locations 1 Tape mounting bracket to wall where heater will be located Make sure mounting bracket is level 2 Mark screw locations on wall See Fig 16 Note Mark only last hole on each end of mounti...

Страница 16: ...ough bracket and into wall anchors 7 Tighten screws until mounting bracket is firmly fastened to wall 8 Check that the bracket is secure before mounting heater Attaching Wall Hanging Spacers to Heater...

Страница 17: ...If gas line pressure is higher heater regulator damage could occur CAUTION Never connect heater directly to an LP supply This heater requires an external regulator not supplied Install the external re...

Страница 18: ...3 5kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa Pres...

Страница 19: ...call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS MANUAL GAS CONTROL 1 ST...

Страница 20: ...h 7 Wait 1 minute before attempting to light pilot again If after several tries the pilot still goes out turn the gas control knob clockwise to the OFF position and call your service technician or gas...

Страница 21: ...service agency PILOT FLAME PATTERN Fig 26 shows a correct pilot flame pattern Fig 27 shows an incorrect pilot flame pattern The incor rect pilot flame is not touching the thermocouple This will cause...

Страница 22: ...flame pattern with lifting and excessive flame height If burner flame is incorrect turn heater off see To Turn Off Gas to Appliance page 19 see Troubleshooting pages 23 through 26 Fig 28 Correct Flame...

Страница 23: ...d using compressed air no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions...

Страница 24: ...itioned wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor or ignition module 7 Bad...

Страница 25: ...r gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Mainte nance page 21 or contact customer...

Страница 26: ...r 3 Clean ODS pilot see Care and Maintenance page 22 Gas odor exists even when control knob is in OFF posi tion 1 Gas leak See Warning Statement at top of page 22 2 Control valve is defective 1 Locate...

Страница 27: ...s no power to the fan 2 Fan is set to AUTO 3 Fan motor is bad 1 Fan housing or blades are dirty 2 Fan rotation is blocked 3 Defective fan 1 See Cleaning Fan page 22 2 Verify wiring is not in fan path...

Страница 28: ...e 1 AQ000112 AQ000112 AQ000112 AQ000112 7 Overheat Limit Switch 1 AQ000042 AQ000042 AQ000042 AQ000042 8 1 NG Regulator Assembly 1 AQ000073 AQ000073 AQ000073 AQ000073 8 2 LP Regulator Assembly 1 AQ0000...