background image

Astria.us.com

126753-01M

12

INSTALLATION  

Continued

GAS LINE HOOK-UP

 WARNING: Gas line hookup should be done by your 

gas supplier or a qualified service person.

 WARNING: Before you proceed, make sure your 

gas supply is OFF.

A manual shutoff valve has been included in the appliance’s gas sup-

ply system. You may consider installing an extra gas shutoff valve 

outside appliance’s enclosure (check with local codes) where it can 

be accessed more conveniently with a key through a wall as shown 

in

 Figure 15.

In conformance with local codes, route a 1/2" NPT gas line to appliance 

through hole in left side of firebox or sub-floor as shown in 

Figure 16.

 CAUTION: Do not kink flexible gas line.

IMPORTANT NOTICE

NFPA 54 defines minimum space requirements for the 

installation of this fireplace.
This fireplace must be installed in an unconfined space 

with a minimum of 50 cubic feet per 1,000 BTUs of 

gas output. Therefore 36” models require 2,650 cu-

bic feet, 42” models require 3,100 cubic feet.. If the 

space you wish to install the fireplace does not meet 

these requirements NFPA 54 details several actions 

that may be taken.

Figure 15 - Manual Shutoff Valve Installation

Typical Exterior Wall Gas 

Shutoff Installation

Key

Extension

Shutoff 

Valve

Figure 16 - Routing Incoming Gas Line

A

B

1/2" NPT Incoming
Black Iron Gas Line

Flexible Gas Line
(1 Provided) Can
Be Extended Out
Either Side

7"

7"

Alternate Gas Supply
Through Sub-Floor

Mission36TMN

(F0859, F0861)

Mission42TMN

(F0865, F0867)

A

5

/

8

" (21.9 cm)

10 

1

/

2

" (26.7 cm)

Figure 17 - Sediment Trap

Incoming 

1/2" Gas Line 

Permitted by 

Local Codes

Sediment 

Trap (Not 

Supplied)

3" Min.

(7.6 cm)

IHP recommends that a black iron gas line be routed from the gas 

source, through a sediment trap 

(see 

Figure 17

and into appliance. 

Once connected through appliance, a flexible gas line may be used 

for ease of installation to gas control valve 

(see 

Figure 18, Page 13

).

Before connecting black iron gas line to inside of appliance a sediment 

trap must be included outside appliance between gas line and gas 

shutoff valve. It must extend down 3" beyond center of pipe. Prepare 

incoming black iron gas line with teflon tape or pipe joint compound 

(Check with local building codes).

 CAUTION: Compounds used on threaded joints of 

gas piping shall be resistant to the action of Liquefied 

Petroleum (LP or propane) and should be applied lightly 

to ensure excess sealant does not enter the gas line.

 WARNING: All gas piping and connections must be 

tested for leaks after the installation is completed.
After ensuring that the gas valve is on, apply a commercial 

leak detection solution to all connections and joints. If 

bubbles appear, leaks can be detected and corrected.
Do not use an open flame for leak testing and do not 

operate any appliance if a leak is detected.

Содержание astria Mission Mission42TMN

Страница 1: ...gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoivent treassur spar un insta...

Страница 2: ...In addition to instructing you on how to install and maintain your appliance it also contains information that will enable you to obtain replacement parts or optional accessory items when needed Keep...

Страница 3: ...A 70 or the Canadian Electrical Code CSA C22 1 15 Do not obstruct the flow of combustion and ventilation air in any way Provide adequate clearances around air openings into the combustion chamber alon...

Страница 4: ...connection Ceramic Log Pack Shrink wrapped on cardboard Three 3 plastic bags containing volcanic stone rock pan and ember materials Rear Log Remove the two plastic quick ties from around the burner a...

Страница 5: ...use as a heating appliance CAUTION Donotconnectappliancebeforepressure testinggaspiping Damagetogasvalvemayresultand an unsafe condition may be caused SELECTING LOCATION To determine the safest and m...

Страница 6: ...inimum Supply Pressure 11 WC 2 74 kPa 11 WC 2 74 kPa Maximum Supply Pressure 13 WC 3 23 kPa 13 WC 3 23 kPa Orifice Size 52 50 Model 36 Model 42 Model 36 Model 42 Model 36 Model 42 A 29 737 mm 36 915 m...

Страница 7: ...TOP VIEW SAFE ZONE Perpendicular Wall Figure 6 Side Clearances Top View Cross Section Mission36TMN F0859 F0861 Mission42TMN F0865 F0867 A 9 229 mm 6 153 mm B 12 305 mm 9 229 mm MANTEL CLEARANCES AND W...

Страница 8: ...tom of the appliance The gas line must be installed through the lower left side access point or alternate access hole in the bottom of the appliance see Figure 16 Page 12 4 Repack insulation around th...

Страница 9: ...y flue servicing a solid fuel burning appliance This appliance may be vented through a manufactured chimney system or a masonry chimney using a B vent adaptor or a chimney liner system if all are list...

Страница 10: ...for Spillage Check this area along entire top edge of fireplace opening Smoke or flame should be drawn into appliance opening CHECKING FOR PROPER VENTING After completing and checking electrical gas...

Страница 11: ...ny of the original wire as supplied must be replaced use 18 AWG TYPE CL2 UL 105 C 25 ft length MAXIMUM or equivalent Wall Switch or Remote Control Not Supplied Figure 14 Wall Switch Wiring Diagram Fig...

Страница 12: ...2 NPT Incoming Black Iron Gas Line Flexible Gas Line 1 Provided Can Be Extended Out Either Side 7 7 Alternate Gas Supply Through Sub Floor Mission36TMN F0859 F0861 Mission42TMN F0865 F0867 A 8 5 8 21...

Страница 13: ...er size pieces and lay on top of surface of pan material see Figure 20 4 Place just enough ember material to cover burner pan material Leave a 1 2 space between pieces Figure 18 Connecting Flexible Ga...

Страница 14: ...between first two grate fingers as shown in Figure 25 and position upper end of log 6 into notched area on front of log 2 as shown in Figure 25 As an option to enhance the look of the hearth you may...

Страница 15: ...og 6 on top of log 2B see Figure 29 As an option to enhance the look of the hearth you may place the volcanic stone provided around front and sides of burner pan NOTE It is important to ensure proper...

Страница 16: ...sulation or caulking If appliance is mounted on a raised platform it must be a continuous surface and not on blocks without a solid surface This will prevent the entry of cold air by means of conducti...

Страница 17: ...not attempt to adjust or clean the glass doors until the appliance has fully cooled The doors may be removed for replacement or cleaning as follows 1 Partially open door and press up on upper spring...

Страница 18: ...e damper in full open position 5 Fully open glass doors if installed 6 Remove front refractory brick access panel 7 Turn gas control knob clockwise to the OFF position see Figure 36 8 Wait five 5 minu...

Страница 19: ...by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material pet hair etc It is imperative that the control compartments burners and circ...

Страница 20: ...ndently of the burner on off wall switch it may be due to the operation of this safety limit switch First allow the appliance to cool then reset the safety switch by pressing the red reset button on t...

Страница 21: ...other possible obstructions 4 Contact your gas supplier 5 Refer to section on pilot lighting 6 Have a qualified technician replace pilot line 7 Replace regulator valve see Accessories Page 28 8 Open v...

Страница 22: ...nt above 2 For propane LP gas low fuel supply 3 Gas leak See Warning statement at top of Page 1 Gas leak See Warning statement at top of Page 2 Control valve defective 1 Foreign matter between control...

Страница 23: ...lso visit our web site at Astria us com REPLACEMENT PARTS See Pages 24 to 27 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered th...

Страница 24: ...2 33 34 2 28 25 35 NG LP WARNING Contact an IHP dealer to obtain any of these parts Never use substitute materials not approved by IHP Use of non approved parts can result in poor performance and safe...

Страница 25: ...AR TRANSITION 6 B VENT 1 21 J3980 ASSY AIR KIT DOOR 36 1 F3457 ASSY AIR KIT DOOR 42 1 22 J6900 PLATE OUTSIDE AIR COVER 36E44 6 1 23 J3992 DEFLECTOR SMOKE 1 J4081 DEFLECTOR SMOKE 1 24 J6895 RETAINER RE...

Страница 26: ...e Stacked 1 12 Refractory Left 1 13 Refractory Right 1 14 Refractory Rear 1 15 Refractory Bottom 1 16 J6379 Refractory Bottom Front White Herringbone 1 16 J6374 Refractory Bottom Front White Stacked 1...

Страница 27: ...CATALOG NO DESCRIPTION QTY J4096 LOG SET 1 J4246 LOG 9 FIREPIT SPLIT 1 2 J7241 LOG REAR 22 1 3 J4242 LOG 11 75 TOP ROUND 1 4 J4243 LOG 16 TOP SPLIT 1 5 J4244 LOG 13 5 Y TOP SPLIT 1 6 J4245 LOG 11 TOP...

Страница 28: ...INSTALLATION Optionalkithelpsoffsetthenegativepressureoftenexistingintoday stightlyconstructed homes Negative pressure may occur when other appliances in the home draw on air possibly leading to poor...

Страница 29: ...p paint powder coat exterior BRICK LINER KIT Not Shown F1059 BL36 36 Texture Refractory Brick Liner Kit F1060 BL36H 36 Texture Refractory Herringbone Brick Liner Kit F10561 BL42 42 Texture Refractory...

Страница 30: ...____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______...

Страница 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 32: ...e uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local dis...

Отзывы: