(16)
Rabbit Monitor
Rabbit monitor on the operation panel allows
integrated control for operational condition of
pump. With the warning display or emergency
shutdown function in case of abnormal
condition, you can use the pump safely.
1. How to check the Monitor
Operation
In setting the main switch to “Operation”,
LED lights on monitor except “F1 Sensor” turn
on for 3 seconds. (As for “M” specifications,
light turns on after starting engine and
increasing the engine speed.) As no light
means something is abnormal, please
contact the maintenance establishment or
distributor for inspection/maintenance.
2. Monitor Display and Countermeasures
Display
Monitor Operation
Countermeasures
Fuel
When the fuel is almost depleted,
LED turns on.
Put the gasoline into the fuel
tank.
2-Cycle Oil
When the oil is not enough, the
engine stops to prevent the
burning out and LED turns on.
“Stop” the main switch, refill the oil in
the oil tank and restart the engine.
Cooling Water
When the water temperature of
cooling water gets higher, the
engine stops to prevent overheat
and LED turns on. (Note.1)
Temperature of cooling water gets
higher. Examine the cause and
eliminate it. You can restart the
engine, however if the cause is not
eliminated, the engine stops again
15 seconds after restarting. (Note 2)
F1 Sensor
Abnormal condition for any of
TPS, WTS, ATS and APS is confirmed,
the light turns on. Furthermore, if
a connector linked with Injector/
ignition coil is disengaged, the light
turns on. The lighting condition is
suggested in annexed sheet 1.
Besides emergency, stop the engine
and contact the maintenance
establishment or distributor for
inspection/maintenance.