iHealth Track KN550-BT Скачать руководство пользователя страница 6

Avoid compression or restriction of the connection tubing during measurement

which may cause 

inflation error, or harmful injury due to continuous cuff pressure.

4. SETTING THE DATE AND TIME

Insert the batteries in the device and connect it with the iHealth MyVitals App on your smartphone. The 

time and date will automatically be updated. If you change the batteries, please readjust the time and date 

again.

5. TAKING A BLOOD PRESSURE MEASUREMENT

   a. After placing the cuff on your arm and relaxing for a few minutes, press the “START/STOP” button. All 

display characters are shown for self-test, please contact the service center if segment is missing. 

   b. The monitor will inflate the cuff and then slowly release pressure from the cuff as the blood pressure is 

measured. When the measurement is finished the blood pressure and pulse rate will be displayed on the 

display. The blood pressure will be displayed in different colours (green for normal, yellow for slightly 

elevated, and red for high) according to the recommendations of the WHO (World Health Organization), 

The result will automatically be stored in the memory bank of the monitor.

   c. If an Irregular Heartbeat (IHB) is detected during a measurement, the IHB symbol will be displayed 

(blinking). If an IHB is detected, the results of the blood pressure measurement may be inaccurate. Please 

consult your physician for an accurate assessment.

   d. At any time you can synchronize your device with the iHealth MyVitals App so that you can better 

manage your blood pressure.

   e. The monitor will automatically switch off after one minute to save the batteries. Alternatively, you can 

press the “START/STOP” button to turn off the monitor manually.

   f. At any time during a measurement, you can interrupt a measurement by pressing the “START/STOP” 

button.

6

Содержание Track KN550-BT

Страница 1: ...ic iHealth Track Connected Arm Blood Pressure Monitor USER MANUAL Note This is a shortened practical version of the user manual For the full version of this user manual please visit www ihealthlabs eu...

Страница 2: ...e 2 Sit comfortably at a table when measuring your blood pressure 3 The cuff should be placed at the same level as your heart 4 Do not talk or move during a measurement 5 Use the same arm every time 6...

Страница 3: ...ure your blood pressure but when you connect it to the free iHealth MyVitals App you will be able to track store manage and share your results with your family doctor or care givers Simply download iH...

Страница 4: ...ttention to polarity c Close the battery cover When the display shows the battery symbol replace all the batteries with new ones Rechargeable batteries are not suitable for this monitor The monitor th...

Страница 5: ...cro fastener d The cuff should fit comfortably around your arm You should be able to insert one finger between your arm and the cuff Note If the cuff becomes dirty remove it from the monitor and wipe...

Страница 6: ...ished the blood pressure and pulse rate will be displayed on the display The blood pressure will be displayed in different colours green for normal yellow for slightly elevated and red for high accord...

Страница 7: ...tton again to review the next measure ment During display the memories keep on pressing button M for three seconds all results in the current memory bank will be deleted If no result stored LCD will s...

Страница 8: ...Health MyVitals App on your smartphone ensure that your Bluetooth is activated in your settings 3 Press the M Memory button on the blood pressure monitor The number of readings in the memory will be d...

Страница 9: ...ure above 15 mmHg Incorrect operation or strong electromagnetic interference EEPROM accessing error Pneumatic system leakage or cuff is too loose during inflation Fail to detect systolic pressure Cuff...

Страница 10: ...he coefficient of variation CV of pulse period 25 b The difference of adjacent pulse period is 0 14s and more than 53 of the total number of pulses readings falls within this definition 5 Please do no...

Страница 11: ...a long time please remove the batteries 6 It is recommended that the performance of this monitor be checked every 2 years 7 Please clean monitor with a soft dry cloth Do not use any abrasive or volat...

Страница 12: ...the product please visit www ihealthlabs eu and consult our Frequently Asked Questions on blood pressure in our support section If you do not find the answers you are looking for please send us a quer...

Страница 13: ...althlabs eu www ihealthlabs eu ANDON HEALTH CO LTD Add No 3 Jinping Street YaAn Road Nankai District Tianjin 300190 China Tel 86 22 60526161 iHealth is a trademark of iHealth Lab Inc The Bluetooth wor...

Страница 14: ...ZE AAA batteries Measurement range Cuff pressure 0 300mmHg Systolic 60 260mmHg Diastolic 40 199mmHg Pulse rate 40 180 beats minute Measuring accuracy Pressure 3mmHg Pulse rate 5 Environmental temperat...