External Signal Exchange
97/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
6098h Homing Method
Short description
Stipulation of the homing method
Parameter Name
Homing_method
Object Type
VAR
0x7
Data Type
INTEGER8
0x0002
Access
RWW
PDO Mapping
Yes
Value assignment
0
17
LSN Limit Switch Negative
1
18
LSP Limit Switch Positive
2
33
IEN Index Encoder Negative
3
34
IEP Index Encoder Positive
4
37
SCP Set Current Position
5
255
AAF Analogue Absolute Feedback
The homing method is set in the user interface. A change via CANopen is not possible but reading of the set value is.
6099h Homing Speeds
Short description
Stipulation of the travel speeds during the homing run (6098h)
Parameter Name
Homing_speeds
Object Type
ARRAY
0x8
Subindex Number
3
6099h sub0 Number of Entries
Parameter Name
Homing_speeds_number_of_entries
Object Type
VAR
0x7
Data Type
UNSIGNED8
0x0005
Access
RO
Standard Value
2
PDO Mapping
No
6099h sub1 Speeds during Search for Switch
Parameter Name
Homing_speeds_Speed_during_search_for_switch
Object Type
VAR
0x7
Data Type
UNSIGNED32
0x0007
Access
RWW
Standard Value
0x0
PDO Mapping
Yes
6099h sub2 Speeds during Search for Zero
Parameter Name
Homing_speeds_Speed_during_search_for_zero
Object Type
VAR
0x7
Data Type
UNSIGNED32
0x0007
Access
RWW
Standard Value
0x0
PDO Mapping
Yes
609Ah Homing Acceleration
Short description
Indication of the acceleration during homing runs
Parameter Name
Homing_acceleration
Object Type
VAR
0x7
Data Type
UNSIGNED32
0x0007
Access
RWW
PDO Mapping
Yes