![IGM MULTIGASSENS-M2 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/igm/multigassens-m2/multigassens-m2_user-manual_3937381005.webp)
MULTIGASSENS-М2 USER MANUAL
Rev. 1.8 07.02.19
5
1.2
Functional principle of the device
For CXHY measurement the device contains a high-capacity low-consuming optical sensor which
functional principle is based on the preferential absorption of infrared radiation by molecules of
hydrocarbons in the field of 3,3 - 3,4 microns wavelengths. For measurement of oxygen and toxic gases
concentration the device contains sensors which utilise the measurement principle of the
electrochemical method.
The device is also has a barometric pressure and temperature sensor to compensate for external
factors affecting the accuracy of measuring the concentration of gases, sensor data is not displayed.
For electrical power; a non-rechargeable chemical current source is used which is calculated
(depending on the modification) for 2 years of continuous operation.
1.3
Technical characteristics
1.3.1
Dimensions, Weight, Power Supply and Power Consumption of Detectors
Таблица 1
Dimensions (L x W x
H) (mm) no greater
than:
Mass, KG, no greater
than:
Electric power source
Power
consumption(max),
VA
120х70х49
0,240
Non-rechargeable chemical
source
0,00072
1.3.2
Operating conditions
Operating conditions of the device are shown in table 2
Table 2
Parameters
Value
Unit measurement
Ambient temperature range
from -40 to +60
С
Atmospheric pressure range
from 80 to 120
кPа
Humidity range
from 25 to 95
% (at+25
о
С)
1.3.3
Technical characteristics in brief
A brief description of technical characteristics of the detectors is specified in Table
3