7. Troubleshooting guide 

Machine does not start or a breaker trips.

 

 

Possible Cause 

1. Power supply switched OFF or is faulty.

2. Wall fuse/circuit breaker is blown/tripped.

3. Faulty remote control.

4. Remote receiver is faulty.

5. Incorrectly wired motor connection.

6. On-board circuit breaker is tripped.

7. Wiring is open/has high resistance.

8. Faulty power switch.

9. Motor is at fault.

 

 

Possible Solution 

1. Ensure power supply is ON and has the correct voltage.

2. Ensure adequate circuit size; install inlet restrictor, replace weak breaker.

3. Replace batteries; ensure unobstructed line-of-sight and signal range.

4. Inspect receiver circuit board; replace if faulty.

5. Rewire or call certified service technician or electrician.

6. Allow motor to cool, improve ventilation, press reset button.

7. Check for broken wires or poor connections, repair as necessary.

8. Replace switch.

9. Test/repair/replace.

Excessive vibration or noise during operation. 

 

Possible Cause 

1. Loose component.

2. Loose or broken motor mount.

3. Motor fan hitting fan cover.

4. Bad motor bearings.

 

 

Possible Solution 

1. Inspect and tighten all bolts/nuts. 

2. Tighten or replace as needed.

3. Check fan and cover; replace as needed.

4. Rotate shaft manually, check for grinding or loose shaft, replace bearings 

if needed.

Loud, repetitive noise, or excessive vibration coming from

cyclone

 

 

Possible Cause 

1. Machine is on uneven surface.

2. Damaged/Unbalanced impeller.

3. Loose connections.

4. Impeller is loose.

5. Motor fan hitting fan cover.

 

 

 

Possible Solution 

1. Stabilize on a flat surface.

2. Inspect impeller for dents, bends, loose fins. Replace if needed.

3. Check and re-tighten all fasteners.

4. Replace the motor and impeller. 

5. Check fan and cover; replace as needed.

Dust cyclone does not adequately collect dust or chips;

poor performance.

 

 

Possible Cause 

1. Canister end cap is full. 

2. Filter is dirty.

3. Restricted duct line.

4. Suction route is too long or has too many sharp bends.

5. Wet lumber is clogging ducts. 

6. Leaks in the duct work or too many open ports.

7. Inadequate velocity in the main suction line.

8. Wrong size ducting/ports used.

 

 

 

Possible Solution 

1. Empty canister end cap.

2. Clean filter.

3. Clean inlet splitter.

4. Move machine closer to the point of suction, and rerun ducts to eliminate 

sharp bends.

5. Use lumber with less than 20% moisture content.

6. Repair all duct leaks and close any ports not being used.

7. Increase velocity by opening 1 or 2 more blast gates to different branch 

lines. 

8. Re-size and re-install ducts and fittings.

Sawdust being blown into the air from the dust cyclone. 

 

Possible Cause 

1. Band clamp or end cap is not secure.

2. Loose or damaged seals.

 

 

Possible Solution 

1. Re-install ensuring a tight fit.

2. Replace seals and gaskets.

3. Remove the (4) 3/16” x 3/4” sheet metal Philip bolts, (1) 5/16” x 3/4” hex 

bolt and (1) 5/16” x 7/8” flat washer off the bottom of the canister filter.

4. Remove the canister filter and carefully tilt the top of the canister filter 

assembly to clear the paddle branches. Slightly bend the paddle branches 

to remove the canister filter.

      

NOTE:

 You may have to gently bend the paddles to free the canister filter. 

This should not adversely affect the operation of the machine. 

5. With the canister filter removed use a compressed air gun to thoroughly 

clean between the pleats, both inside and outside. 

RE-ASSEMBLING THE CANISTER FILTER AFTER CLEANING

6. With the aid of another person, carefully re-insert the canister filter 

repeating step 1,2,3 and 4 in reverse. 

Содержание LAGUNA PFlux3Tv2 2022

Страница 1: ...istributor IGM n stroje a stroje s r o Ke Kopanin 560 252 67 Tuchom ice Czech Republic EU Phone 420 220 950 910 E mail sales igmtools com Website www igmtools com 2022 08 18 151 PFlux3Tv2 LAGUNA Cyclo...

Страница 2: ...2 www igmtools com...

Страница 3: ...the workshop If a procedure feels dangerous don t try it Figure out an alternative procedure that feels safer REMEMBER Your personal safety is your responsibility This machine was designed for certai...

Страница 4: ...ace surrounding work area and non glare overhead lighting Keep the floor around the machine clean and free of scrap material oil and grease Keep visitors a safe distance from the work area Keep childr...

Страница 5: ...This appliance must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding termi...

Страница 6: ...ng or damaged parts to your dealer or distributor Prior to tool assembly and use read this manual thoroughly to familiarize yourself with proper assembly maintenance and safety procedures 5 2 General...

Страница 7: ...r upright support panels to the unit using 6 5 16 3 4 hex bolts and 6 5 16 OD18 2t flat washers Step 8 Secure the 3 upright support reinforcement plates using 12 5 16 3 4 hex bolts and 12 5 16 OD18 2t...

Страница 8: ...rotation shaft assembly into the HEPA filter from the top opening It will be easier to insert while holding it at a slanted angle The rotation shaft has a top and bottom end The top end has bolt hole...

Страница 9: ...ot pedal bar and securing the U channel provided onto the foot pedal bar using 2 5 16 1 3 4 hex bolts 4 5 16 OD18 2t flat washers and 2 5 16 hex nuts from the inside out Follow the same steps for the...

Страница 10: ...ach the crossbar Step 37 Assemble the Octagon drum Locate the drum base panel it does not matter which side faces inside and secure the 4 casters using 16 5 16 x 3 4 hex bolts 32 5 16 x 1 flat washers...

Страница 11: ...1 2 and 24 Cap nut 3 16 to assemble the drum insert together Place the drum insert inside over the plastic bag in the Octagon drum Step 47 Lift the foot peddle bar Align the Octagon drum window to the...

Страница 12: ...es of the Canister filter shield doors Connect the 4 flex hose from the cyclone to the 4 hook up on the canister end cap 2 While the cyclone is collecting the dust from inside the canister end cap use...

Страница 13: ...all fasteners 4 Replace the motor and impeller 5 Check fan and cover replace as needed Dust cyclone does not adequately collect dust or chips poor performance Possible Cause 1 Canister end cap is ful...

Страница 14: ...14 www igmtools com 8 POWER CONNECTIONS WIRING DIAGRAMS CONTROL PANEL POWER CONNECTIONS...

Страница 15: ...15 www igmtools com AUTOCLEAN MOTOR SECONDARY JUNCTION BOX...

Страница 16: ...16 www igmtools com 9 Parts breakdown Exploded Views 2021 10 14 X s I q...

Страница 17: ...F22201 16D HEX NUT 5 16 4 16E PDCPF22201 16E DRUM CASTER 3 4 16U PDCPF22201 16U HEX BOLT 5 16 x 3 4 16 16F PDCPF22201 16F FLAT WASHER 5 16 xOD18x2t 32 16G PDCPF22201 16G HEX NUT 5 16 16 16H PDCPF22201...

Страница 18: ...R ALARM 1 44 PDCPF22201 44 PHILIP HD BOLT M4 6mm 4 45 PDCPF22201 45 RUBBER HANDLE FOR DRUM INSERT 4 46 PDCPF22201 46 CONTROL PANDLE HANDLE 2 46A PDCPF22201 46A PHILIP HD BOLT M4 6mm 4 47 PDCPF22201 47...

Отзывы: