Technical data of IGLU Aleut WT fixed capacity heat pump with water
heater
Units
5 kW
7 kW
9 kW
11 kW
13 kW
Brine/water used
Thermal power (B0/W35)
1)
kW
5.24
7.25
9.22
10.95
13.07
Thermal power (B0/W45)
1)
kW
4.89
6.85
8.67
9.98
12.30
COP (B0/W35)
1)
-
4.37
4.42
4.45
4.52
4.54
COP (B0/W45)
1)
-
3.37
3.42
3.47
3.41
3.47
SCOP (B0/W35)
-
5.55
5.66
5.72
5.86
5.77
SCOP (B0/W45)
-
4.14
4.22
4.26
4.37
4.3
Brine circuit
Rated flow (DT = 3K)
2)
m
3
/h
1.50
2.0
2.50
3.00
3.50
Permissible external pressure drop
2)
kPa
45
80
91
90
85
Maximum pressure
bar
4
Volume (internal)
l
5
Operating temperature
°C
from -10 to +20
Connection (Cu)
mm
28
Compressor
Type
“Scroll”
Mass of refrigerant R 407C
3)
kg
1.20
1.30
1.35
1.40
1.50
Maximum pressure
bar
45
Heating system
Rated flow (DT = 7K)
m
3
/h
1.00
1.50
2.00
2.00
2.20
Min. flow temperature
°C
15
Max. flow temperature
°C
60
Max. permissible operating pressure
bar
4.0
Hot water tank volume
l
200
Capacity material
-
Stainless steel 1,4404
Connection (Cu)
mm
28
Power network connection values
Electrical connections
400 V 3 N~50 Hz
Inertial fuse; with electric heater 3 kW
A
10-16-20
16/16/20
16/20/25
16/25/25
20/25/32
Compressor rated power (B0/W35)
kW
1.19
1.64
2.06
2.56
3.06
Max. current with inrush current limiter
4)
A
4.10
5.20
6.80
8.23
10.10
Type of protection
IP
X1
General information
Permissible ambient temperatures
°C
from +10 to +35
Sound power level
5)
dBA
42
Dimensions (width x depth x height)
mm
700 x 700 x 1750
Weight (without packaging)
kg
187
195
200
215
220
1) With internal pump according to EN 14511
2) With ethylene glycol
3) Greenhouse potential, GWP100 = 1774
4) WPS 6-1: Max. current without inrush current limiter
5) According to EN 3743-1
Содержание Aleut Series