sary to ensure even load of shelves and not to exceed the maximum load.
• The first filling of cooling space should be performed after its previous cooling to working temperature. This
principle should also be observed after longer pause in exploitation.
• Do not block any ventilation holes, which would hamper circulation of the cooled air (Do not place the
products directly to the screen!). It is also necessary to ensure proper airflow around the device (aggregate
ventilation holes cannot be covered).
• Keep the condenser clean. Impurities may lead to overheating of the compressor and as a consequence
may result in damage of the device, which is not covered by warranty.
• Do not use electric devices inside grocery product storing chamber.
• When the rack is used without the need to display goods (night work; closed post, shop) it is recommen-
ded to drop roller blinds in order to reduce consumption of electric energy
• Make sure whether the front panel is properly closed and whether it fits tight to the body of the device.
4.1. Temperature regulation
Service of “Igloo” and “Carel” thermostat (temperature regulators) is described in chapter 7
(p. 20 and 21)
The basic aim of a thermostat is to control the cooling aggregate to obtain the set temperature within the device
and maintain it within the determined temperature ranges. The producer enters all settings of temperature regu-
lators required for normal functioning of the device. Before primary actuation the user should control and possibly
set the required temperature inside the device on the control panel.
Digital display – displays the current temperature inside the device.
It is forbidden to interfere with systemic parameters of the thermostat, as this can lead to serious
consequences, including the damage of the cooling device!
4.2. Humidity regulation
The humidistat controls the humidity, when the temperature in the unit is in the range from +10°C to +15°C. Using
the humidistat knob, set the desired humidity in the unit in the range from 40 to 90% by turning the knob and
setting it in place. Rotating the knob clockwise raises the humidity setting, and turning it in the opposite direction
reduces it.
5. MAINTENANCE
5.1. Cleaning and maintenance
All maintenance services need to be performed after disconnecting the device from power supply!
Protect electric installation against any damage or water spillage
Do not use water stream to clean the device, only a wet cloth
Do not use any sharp objects to remove filth!
Fig.4 Humidistat