7.2. „CAREL” thermostat

Fig.14 „Carel” thermostat control panel

WHAT DO DIODES ON CONTROL PANEL SIGNIFY

Diode 1 is on - Compressor:

  the symbol is visible when the compressor is working.  It is blinking when compressor 

actuation is delayed by security procedure.  It blinks in the following cycle:  two blinks – pause, when the constant working 

mode is activated.

Diode 2 is on - Ventilator:

  the symbol is visible when evaporator ventilators are turned on.  It blinks when the actuation 

of the ventilators is delayed by external disengagement or when another procedure is in progress.

Diode 3 is on - Defrosting: 

 the symbol is visible when the defrosting function is activated.  It blinks when the actuation 

is delayed by external disengagement or when another procedure is in progress.

Diode 4 is on - Alarm: 

 the symbol is visible when the alarm is activated.

– current temperature inside the device is displayed (decimal places displayed after the comma)

SETTING THE DESIRED TEMPERATURE

- press for 1 second 

 leading value shall be displayed on the screen;

- increase or decrease the leading value by means of  

 and 

, switches, until the desired value shall be obtained;

- press                 once again in order to confirm the new value of the setting point;

MANUAL INPUT OF THE DEFROSTING CYCLE

Defrosting shall be realised in an automatic mode. It is possible to force defrosting at any moment by pressing and holding 

the   

 switch  for minimum 5 seconds. Diode No. 1 shall blink during manual defrosting.

* Read more on www.alfaco.pl

NOTE: IN CASE OF NOT OBSERVING THE PRINCIPLES ON CONNECTING AND USING THE DEVICE INCLU-

DED IN THIS MANUAL, THE PRODUCER SHALL RESERVE THE RIGHT TO RECEDE FROM OBLIGATIONS OF 

THE GUARANTOR!!!

Information included in this document may be altered by “IGLOO” without noticing the user.  

Copying the present manual without the consent of the producer is forbidden. 

Images and drawings are of demonstrative character and may differ from the purchased device.

1

2

3

4

5

Содержание INN100.110

Страница 1: ...quipped in dynamic cooling automatic condensation evaporation and defrosting The display case is also equipped with an electronic thermostat which works optionally with the temperature registration module that enables registration and signalling high and low temperatures in the unit Display cases are adapted to connect in sequences and can be powered by an internal unit within the temperature rang...

Страница 2: ...em 5 Internal surfaces with glass shelf 6 Suction DO NOT BLOCK the vents 7 Airflow DO NOT BLOCK the vents 8 Plinth block 9 Legs used to level the unit 10 Control panel thermostat switches Rys 2 Control panel 1 Main switch switches on off the unit 2 Light switch 3 Electromagnetic lock the front glass extension 4 Thermostat panel temperature controller the details of operating in Chapter 7 ...

Страница 3: ...p clean 15 Bumbon Silicone element protecting glass components from moving and allowing for better grip Do not dama ge during operation and maintenance 16 Aluminium profile glass shelf support with backlight 17 Internal surfaces with glass shelf 18 Composite side glass with screen printing 19 Airflow DO NOT BLOCK the vents 2 3 Technical data Table 1 Technical data Type of the device INNOVA Rated v...

Страница 4: ... with plug in socket with protecting pin according to PBUE Regulations concerning Electric Equipment Construction 3 2 Connection and actuation Unpack the device and remove the wooden platform from the basis Fig 3 p 15 The device should be placed on an even and on a sufficiently hard base and then level it with the help of levelling feet Remove the protection foil from the elements of the device f ...

Страница 5: ... chapter 7 p 20 and 21 The basic aim of a thermostat is to control the cooling aggregate to obtain the set temperature within the device and maintain it within the determined temperature ranges The producer enters all settings of temperature regu lators required for normal functioning of the device Before primary actuation the user should control and possibly set the required temperature inside th...

Страница 6: ...s out switch on the open close lock button on the control panel at the back of the unit and then press the release lock while slightly pressing against the wooden casing for the lock to let go To draw the front glass back in lightly press near the lock for the lock button to switch on To completely prevent from opening the front glass by unauthorized persons turn off the power of the electromagnet...

Страница 7: ...ient temperature does not exceed 25ºC Enough time has passed for products to be cooled Ventilation holes of the device are not blocked This concerns the IGLOO thermostat thermostat displays C0 or C1 or C2 instead of displaying temperature This situation shall occur when one of temperature regulation sensors has been destroyed The following messages may be displayed in such case C0 temperature sens...

Страница 8: ...essary clean the condenser Condenser ventilator is working properly Ambient temperature does not exceed 25ºC The device is working too loud Make sure that The device is standing stably and is properly levelled Furniture adjoining the device do not vibrate when the cooling aggregate compressor is working 6 2 Service IGLOO service telephone number 48 14 662 19 56 or 48 605 606 071 e mail serwis iglo...

Страница 9: ...e decrease the temperature to the desired value The preview shall finish automatically after about 3 seconds Manual defrosting switch No 2 enables to initiate the defrosting cycle at any moment when the device is working re gardless of the automatic defrosting function the switch shall not operate when the temperature is higher than the final defrosting temperature The user should switch on switch...

Страница 10: ...mperature inside the device is displayed decimal places displayed after the comma SETTING THE DESIRED TEMPERATURE press for 1 second leading value shall be displayed on the screen increase or decrease the leading value by means of and switches until the desired value shall be obtained press once again in order to confirm the new value of the setting point MANUAL INPUT OF THE DEFROSTING CYCLE Defro...

Страница 11: ...en 23 User manual INNOVA www igloo pl Correspondence Stary Wiśnicz 289 32 720 Nowy Wiśnicz Poland NIP 868 000 50 40 Tel 48 14 662 19 10 fax 48 14 662 19 12 e mail info igloo pl www igloo pl ...

Отзывы: