MAINS PLUG FUSE REPLACEMENT

Fuse Cover

Fuse Replacement (Class I)

This appliance must be earthed. Remove the fuse cover 
with a small fl at head screw driver. Take out the fuse and 
replace with a new fuse of the same Amp. Replace the 
fuse cover and push back into place.

TROUBLE SHOOTING

Please refer to the trouble shooting guide when experiencing an issue with your heater. If you still cannot 
determine the fault then please call our Customer Services number 01473 271272

Problem 

Possible Cause 

Solution

The appliance does 
not work.

The appliance is not properly 
plugged into the wall socket.

Plug the appliance in fi rmly.

The appliance is not switched on.

The heater is 
getting too hot.

Make sure the appliance is switched on.

There is no electricity running 
through the mains wall socket.

Block up any drafts with draft 
excluders.

The room is too 
hot.

The chosen setting is too high.

Check the fuse or breaker.

The chosen setting is too low.

Draft from windows or door.

Switch on an additional element.

Switch off an element switch.

Содержание IG9509

Страница 1: ...ain for future reference Before switching on your appliance Always check for any damage which may have been caused in transit IG9509 800W Quartz Heater USER MANUAL Batch code IMPORTANT THIS PRODUCT IS...

Страница 2: ...leaning and user maintenance shall not be made by children Keep the appliance and its cord out of reach of children Children shall not play with the appliance The appliances cannot be used by persons...

Страница 3: ...d burns do not let bare skin touch the hot surface Switch off and let the appliance cool before moving or touching Ensure that the heater is not positioned close to curtains or furniture as this may c...

Страница 4: ...ds The most common cause of overheating is deposits of dust or fluff in the appliance Ensure these deposits are removed regularly by unplugging the appliance and vacuum cleaning the grilles Use this a...

Страница 5: ...sh Body Housing SPECIFICATIONS Quartz Heater IG9509 Igenix White 800W Product Model Number Brand Colour Wattage W 50 60Hz 220 240V 0 95 I Frequency Hz Voltage V Net Weight kg Class 400W 800W Yes Power...

Страница 6: ...ge control with no room and or outdoor temperature feedback fan assisted heat output no Type of heat output room temperature control select one single stage heat output and no room no temperature cont...

Страница 7: ...material and the power socket OPERATING INSTRUCTIONS 1 Insert the plug into a suitable socket ensuring the lead is neither near the heat source nor a tripping hazard 2 Switch the appliance on and off...

Страница 8: ...then please call our Customer Services number 01473 271272 Problem Possible Cause Solution The appliance does not work The appliance is not properly plugged into the wall socket Plug the appliance in...

Страница 9: ...collected separately in order to optimise the recovery and recycling of the materials they contain and reduce the impact on human health and the environment The crossed out wheeled bin symbol on the...

Страница 10: ...over accessories or consumable parts that require replacement under normal use This includes shelving dials filters belts and trays etc In the unlikely event of a breakdown please refer to the Trouble...

Страница 11: ...ble on our website www igenix co uk To register your product please complete all sections of the form below and return to us at the following address lgenix 38 Bluestem Road Ransomes Europark Ipswich...

Страница 12: ...claimer Igenix operate a policy of continual improvement and development We therefore reserve the right to change alter the specification and appearance of our appliances without prior notice All diag...

Отзывы: