6
Timer setting:
The temperature display “19” will display
The first number is 1, this means the heater is on the first running time, 2 for the second running time
and so on. The maximum number of running times you can set is 4.
The hour
“17” and minute “18” will display the last setting time, and the “17” will flash.
Press the downwards adjustment “5” or upwards adjustment “6” to set the desired time you wish for the
heater to start to work (E.g. 07 = 07:00am)
Press SET “3” to finish the setting time
Then the minute display “18” will begin to flash
Press
the downwards adjustment “5” or upwards adjustment “6” to set the desired time you wish for the
heater to stop working (E.g. 11 = 11:00am)
Press SET
”3” to finish the setting time
Please note the timer can be set in hour intervals only
This would mean the heater was programmed to run between 07.00am and 11.00am
Then the “19” display shows 2, you are now on the second running time and you can repeat your
settings for this time frame and so on.
Then press OK “4” to finish the timer setting completely.
Please note
that the setting program will only save once you press the OK “4” button.
Factory pre-setting running time is running between 07.00am -11:00am; then switch off and will resume
running again between 13.00pm and 18.00pm.
To set the running time in one week:
After you have set the first day, you can press
OK “4” for 3 seconds to copy and save the data to the
following days.
Please note that the timer setting will only copy for the following days, (eg, when you are setting the
Wednesday running time and press
OK “4” for 3 seconds, the Thursday to Sunday would be in the
same running time, but Monday and Tuesday could not copy the data.)
After you have set the first day, it can go onto the following day setting, you can set the different
running time according to the method above
After setting the running program
:
Press OK
“4” to save and the heater will operate in accordance to those on and off times that have
been set
If it is not in the pre set running time, the device will turn off after 10 seconds
.
Mechanical “M” mode timer setting (the timer just for that current day)
Press M/A “2” and select the mechanical mode, LCD display “M”
This will turn the heater on and it will remain on until the power button is pressed to switch off, or a time
period is set for the heater to run and then switch off at the end.
To set the time period for the heater to be on Press S
ET “3”.
The Hour display “17” will flash,
Press the downwards adjustment “5” or upwards adjustment “6” to set the desired amount of hours you
wish for the heater to be running (eg 09 ).
Press SET “3” again to set the minute
Press the downwards adjustment “5” or upwards adjustment “6” to set the desired amount of minutes
you wish for the heater to be running (eg 15)
For example; if you set the time to 09:15 the heater will run for 9 hours and 15 minutes and then switch
off.
Press OK “4” to confirm the time period.
The Timer symbol ”16” will light up,
If you press SET “3” when setting the minute this will cancel the timer setting.
Negative Ion Function
This model does not have a negative ion function, but the
“ION” “13” will display on the screen as it is a
factory setting,
To remove the “ION” display, press the high/low power selector “7” for 3 seconds to make it disappear
.