Assembly
•
The radiator will make cracking noises when it is first turned
on and when it is turned off and cooling down.
Location of the Radiator
The radiator should be positioned where you most need the warmth. It is recommended to place the radiator underneath the
coldest window in the room as this helps to increase the convective movement of the heat. Do not locate the radiator
underneath a fixed power point and always ensure that the radiator is placed at least 50cm away from furniture, curtains, walls
etc.
Thermostat
The thermostat controls the heat output according to the room temperature. This makes the heater more economical to run as it
will not produce heat when the room is too warm. To set the required temperature you require, turn the thermostat dial clockwise
until the required setting is reached. If the room needs to be heated up quickly , turn the thermostat dial up fully. When the
desired room temperature is reached, turn the thermostat dial anti-clockwise until the thermostat ‘clicks’ off. The heater will then
maintain the required room temperature and will switch on and off automatically which will be indicated by the Power Indicator
lamp turning on and off.
Note: If the heater does not come on when the thermostat is at a low setting, this may be due to the room temperature being
higher than the thermostat setting.
Power Level Dial
The Power Level dial provides a choice of heat output to suit varying conditions and for economy of operation.
Model
Position 1
Position 2
Position 3
IG1600
400W
600W
1000W
IG1650
700W
800W
1500W
IG2600
900W
1100W
2000W
IG2605
900W
1100W
2000W
IG2650
1200W
1300W
2500W
IG2655
1200W
1300W
2500W
Timer Instructions (IG2605 & IG2655 Only)
The timer on the radiator is a 24 hour programmable timer with 15 minute interval settings and 48 on/off cycles everyday. To set
the timer please follow the instructions below:
1. Firstly set the current time. Rotate the dial (E) in a clockwise direction until the arrow points to the right time (if it is 9:00am
at present, rotate the dial until the arrow points to 9. Fig 1
2. Push the required segments outwards. Each segment represents 15 minutes. E.g. If the heater needs to work from 10:15 to
11:00, push the 3 segments between outwards between 10:15 and 11:00. Fig 2.
Note: The programmed setting will be retained unless it is changed or the radiator is switched off. Once the radiator is switched
off, the timer will need resetting the next time it is used.
Oil Filled Radiator at a Glance
Operating Instructions
Using your Radiator for the First Time
•
When the radiator is turned on for the first time, operate at
its maximum heat setting for at least two hours. Ensure you
are in a well ventilated area during this time as the heater
will give off a “new” smell. This is completely normal.
A. Carry Handle
B. Power Indicator
C. Adjustable Thermostat
D. Power Level Selector
E. Timer ( IG2655
Only)
F. Integrated Cord Storage
G. Easy-Move Castors
B
C
A
F
G
D
E