13. Fault analysis
Display
Description
State-1
Permanent red LED
Current output < 2,1mA
FARB2 faulty
Permanent red LED
Permanent red LED
Display
„Shrt“
Current output > 24mA
Probe short-circuited
Permanent red LED
Permanent red LED
Display
„OPEn“
Current output 3,5mA
Probe open
Permanent red LED
Permanent blue LED
Display
„Shrt“
Current output > 24mA
Probe short-circuited
Permanent red LED
Permanent blue LED
Display
„OPEn“
Current output 3,5mA
Probe open
This high-quality IGEMA product was designed, manufactured and tested with the
application of the QM System guidelines in accordance with DIN EN ISO 9001:2015.
If the device supplied indicates transport damage or gives cause for complaint in
spite of our final quality control please contact our SERVICE department on
telephone
+49 2501 92424-0
by return.