8.2 Connection magnetic switch
•
Open switch housing (1) and remove foam cushions between transmitter tube (4) and
magnetic switch(es) (2).
•
The magnetic switches are already rigidly mounted inside of the switch housing and
electrically connected to the terminals.
The magnetic switch can be connected optionally as breaker, maker or change-over
contact. Switch base is marked with an arrow.
•
If the switch is correctly mounted, the arrow should point downwards.
•
Carry out electrical connection.
•
Finally ensure that no cable gets in contact with hot elements.
8.3 Technical data magnetic switch
Kind of contact
bistable
Contacts
1 breaker / 1 maker
Connection wire
1 x 0,5 mm² (16 x ø 0,2)
– Cu tinned / PTFE
Wire length L
200 mm
Max. perm. temperature
-70°C bis +260°C
Type
Switching voltage U Switching current I Max. power UxI
M130-K
250 VAC
1 A
150 VA
M130-KS
24 VAC
0,065 A
1,5 VA
24 VDC
0,008 A
0,12 VA
Type
Article-No.
Contakt material
M130-KG
15-01122
Silber-Palladium AgPd 70/30 massiv,
hard-gold plated AuCo 4-6µm
8.4 Insulation of electrical components
Electronic and electrotechnical components must not be insulated.
These products must not exceed the maximum permissible temperature.
Otherwise, the components will be destroyed and will cause total failure.
If the devices and other associated electronic components will be
isolated, this is at your own risk.
IGEMA GmbH assumes no liability for damage caused by the insulation
of the device and its components
Caution
Содержание BA14